Metropoli BBS
VIEWER: !oem5120.cfg MODE: TEXT (CP437)
;╔═════════════════════════════════════════════════════════════════╗
;║                                                                 ║
;║                 Token ring Network 16/4 Adapter II              ║
;║            Adapter Configuration File   Version 1.00            ║
;║                                                                 ║
;╚═════════════════════════════════════════════════════════════════╝

BOARD
  ID = "OEM5120"
  NAME = "Token ring Network 16/4 Adapter II"
  MFR = "OEM"
  CATEGORY = "NET"
  SLOT = ISA16
  LENGTH = 285
  AMPERAGE = 700
  SKIRT = NO
  READID = NO
  BUSMASTER = 1
  IOCHECK = INVALID
  DISABLE = UNSUPPORTED

  COMMENTS = "\nThe Token ring Network 16/4  Adapter II
              is designed for use in ISA and EISA bus computers.\n\n
              The EISA configuration utility will identify a conflict-
              free configuration of system resources and suggest
              switch settings for the adapter. Prior to exiting the
              utility, record the suggested switch settings, then exit
              and set switches manually on the adapter before continuing
              any Token ring 16/4 Adapter II operation.\n
              NOTE: To activate a change of the switch settings
              a power ON/OFF cycle must be executed"


SWITCH(1) = 12
  NAME = "SW1 Configuration Switch"
  STYPE = DIP
  VERTICAL = YES
  REVERSE = YES
  LABEL = LOC(1-12) "1" "2" "3" "4" "5" "6" "7" "8" "9" "10" "11" "12"
  FACTORY = LOC(1-12) 111111111111
  COMMENTS = "\nSwitch Block SW1 is an 12-position configuration DIP-switch
              used to set the IO address / interrupt level / DMA channel /
              Ring Speed / Cable Type and to enable Remote Program Load.
              Three positions of SW1 (1-3) are used to set the ROM address /
              IO address and the remaining nine positions are used to set the
              interrupt level , DMA level , Ring Speed.\n
              Please refer to the Token ring Network 16/4 Adapter II
              Installation Guide for further details on switch
              settings."

FUNCTION = "Token ring Network 16/4 Adapter II"
  TYPE = "NET,TOK"
  CONNECTION = "8-Pin RJ45 and 9-Pin D-Connector"

  SUBFUNCTION = "IO Base Address, RPL Setting"
    COMMENTS = "The factory default IO Base address location for the adapter
                is 86A0 and can vary from 86A0 to F6A0. The selected
                IO Base address must also be set in the Protocol.Ini file
                used by the software.
                The REMOTE PROGRAM LOAD function will be enabled via the
                card switch number 8."

    CHOICE = "86A0,RPL Disabled"
      LINK
        PORT = 086A0h-086AFh
              SHARE = NO
              SIZE = BYTE
            INIT = SWITCH(1) LOC(1-3) 111
            INIT = SWITCH(1) LOC(6-7) 11
            INIT = SWITCH(1) LOC(8) 1

    CHOICE = "86A0,RPL Enabled"
      LINK
        PORT = 086A0h-086AFh
              SHARE = NO
              SIZE = BYTE
            INIT = SWITCH(1) LOC(1-3) 111
      LINK
 INIT = SWITCH(1) LOC(1-3) 111
            INIT = SWITCH(1) LOC(6-7) 11
            INIT = SWITCH(1) LOC(8) 0

        MEMORY = 16K
 ADDRESS = 0C0000h
          WRITABLE = NO
          SIZE = BYTE

    CHOICE = "96A0,RPL Disabled"
      LINK
        PORT = 096A0h-096AFh
              SHARE = NO
              SIZE = BYTE
            INIT = SWITCH(1) LOC(1-3) 011
            INIT = SWITCH(1) LOC(6-7) 11
            INIT = SWITCH(1) LOC(8) 1

    CHOICE = "96A0,RPL Enabled"
      LINK
        PORT = 096A0h-096AFh
              SHARE = NO
              SIZE = BYTE
            INIT = SWITCH(1) LOC(1-3) 011
            INIT = SWITCH(1) LOC(6-7) 11
            INIT = SWITCH(1) LOC(8) 0
      LINK
 INIT = SWITCH(1) LOC(1-3) 011

        MEMORY = 16K
 ADDRESS = 0C4000h
          WRITABLE = NO
          SIZE = BYTE

    CHOICE = "A6A0,RPL Disabled"
      LINK
        PORT = 0A6A0h-0A6AFh
              SHARE = NO
              SIZE = BYTE
            INIT = SWITCH(1) LOC(1-3) 101
            INIT = SWITCH(1) LOC(6-7) 11
            INIT = SWITCH(1) LOC(8) 1

    CHOICE = "A6A0,RPL Enabled"
      LINK
        PORT = 0A6A0h-0A6AFh
              SHARE = NO
              SIZE = BYTE
            INIT = SWITCH(1) LOC(1-3) 101
            INIT = SWITCH(1) LOC(6-7) 11
            INIT = SWITCH(1) LOC(8) 0
      LINK
 INIT = SWITCH(1) LOC(1-3) 101

        MEMORY = 16K
 ADDRESS = 0C8000h
          WRITABLE = NO
          SIZE = BYTE

    CHOICE = "B6A0,RPL Disabled"
      LINK
        PORT = 0B6A0h-0B6AFh
              SHARE = NO
              SIZE = BYTE
            INIT = SWITCH(1) LOC(1-3) 001
            INIT = SWITCH(1) LOC(6-7) 11
            INIT = SWITCH(1) LOC(8) 1


    CHOICE = "B6A0,RPL Enabled"
      LINK
        PORT = 0B6A0h-0B6AFh
              SHARE = NO
              SIZE = BYTE
            INIT = SWITCH(1) LOC(1-3) 001
            INIT = SWITCH(1) LOC(6-7) 11
            INIT = SWITCH(1) LOC(8) 0
      LINK
 INIT = SWITCH(1) LOC(1-3) 001

        MEMORY = 16K
 ADDRESS = 0CC000h
          WRITABLE = NO
          SIZE = BYTE

    CHOICE = "C6A0,RPL Disabled"
      LINK
        PORT = 0C6A0h-0C6AFh
              SHARE = NO
              SIZE = BYTE
            INIT = SWITCH(1) LOC(1-3) 110
            INIT = SWITCH(1) LOC(6-7) 11
            INIT = SWITCH(1) LOC(8) 1

    CHOICE = "C6A0,RPL Enabled"
      LINK
        PORT = 0C6A0h-0C6AFh
              SHARE = NO
              SIZE = BYTE
            INIT = SWITCH(1) LOC(1-3) 110
            INIT = SWITCH(1) LOC(6-7) 11
            INIT = SWITCH(1) LOC(8) 0
      LINK
 INIT = SWITCH(1) LOC(1-3) 110

        MEMORY = 16K
 ADDRESS = 0D0000h
          WRITABLE = NO
          SIZE = BYTE


    CHOICE = "D6A0,RPL Disabled"
      LINK
        PORT = 0D6A0h-0D6AFh
              SHARE = NO
              SIZE = BYTE
            INIT = SWITCH(1) LOC(1-3) 010
            INIT = SWITCH(1) LOC(6-7) 11
            INIT = SWITCH(1) LOC(8) 1


    CHOICE = "D6A0,RPL Enabled"
      LINK
        PORT = 0D6A0h-0D6AFh
              SHARE = NO
              SIZE = BYTE
            INIT = SWITCH(1) LOC(1-3) 010
            INIT = SWITCH(1) LOC(6-7) 11
            INIT = SWITCH(1) LOC(8) 0
      LINK
 INIT = SWITCH(1) LOC(1-3) 010

        MEMORY = 16K
 ADDRESS = 0D4000h
          WRITABLE = NO
          SIZE = BYTE

    CHOICE = "E6A0,RPL Disabled"
      LINK
        PORT = 0E6A0h-0E6AFh
              SHARE = NO
              SIZE = BYTE
            INIT = SWITCH(1) LOC(1-3) 100
            INIT = SWITCH(1) LOC(6-7) 11
            INIT = SWITCH(1) LOC(8) 1


    CHOICE = "E6A0,RPL Enabled"
      LINK
        PORT = 0E6A0h-0E6AFh
              SHARE = NO
              SIZE = BYTE
            INIT = SWITCH(1) LOC(1-3) 100
            INIT = SWITCH(1) LOC(6-7) 11
            INIT = SWITCH(1) LOC(8) 0
      LINK
 INIT = SWITCH(1) LOC(1-3) 100

        MEMORY = 16K
 ADDRESS = 0D8000h
          WRITABLE = NO
          SIZE = BYTE

    CHOICE = "F6A0,RPL Disabled"
      LINK
        PORT = 0F6A0h-0F6AFh
              SHARE = NO
              SIZE = BYTE
            INIT = SWITCH(1) LOC(1-3) 000
            INIT = SWITCH(1) LOC(6-7) 11
            INIT = SWITCH(1) LOC(8) 1
    CHOICE = "F6A0,RPL Enabled"
      LINK
        PORT = 0F6A0h-0F6AFh
              SHARE = NO
              SIZE = BYTE
            INIT = SWITCH(1) LOC(1-3) 000
            INIT = SWITCH(1) LOC(6-7) 11
            INIT = SWITCH(1) LOC(8) 0

      LINK
 INIT = SWITCH(1) LOC(1-3) 000

        MEMORY = 16K
 ADDRESS = 0DC000h
          WRITABLE = NO
          SIZE = BYTE



  SUBFUNCTION = "Interrupt Level"
    TYPE = "INT"
    COMMENTS = "The Token ring Network 16/4 Adapter II
                can operate on one of four interrupt levels: 9 ,10 , 10
                and 15. The factory default interrupt level is 9."

    CHOICE = "Interrupt 9"
    SUBTYPE = "9"
      LINK
        IRQ = 9
          SHARE = NO
          TRIGGER = EDGE
        INIT = SWITCH(1) LOC(4 5) 11
    CHOICE = "Interrupt 10"
    SUBTYPE = "10"
      LINK
        IRQ = 10
          SHARE = NO
          TRIGGER = EDGE
        INIT = SWITCH(1) LOC(4 5) 01
    CHOICE = "Interrupt 11"
    SUBTYPE = "11"
      LINK
        IRQ = 11
          SHARE = NO
          TRIGGER = EDGE
        INIT = SWITCH(1) LOC(4 5) 10
    CHOICE = "Interrupt 15"
    SUBTYPE = "15"
      LINK
        IRQ = 15
          SHARE = NO
          TRIGGER = EDGE
        INIT = SWITCH(1) LOC(4 5) 00




  SUBFUNCTION = "DMA Level"
    COMMENTS = "\nUp to three Token ring Network 16/4 Adapter II
                may be installed within a single computer. When
                multiple adapters are being installed in a single computer,
                each adapter must be assigned to a different DMA channel.
                Select the appropriate function within the EISA
                Configuration Utility to display the switch setting(s)."


    CHOICE = "DMA 5"
      LINK
        DMA = 5
          SHARE = NO
        INIT = SWITCH(1) LOC(9 10) 11
    CHOICE = "DMA 6"
      LINK
        DMA = 6
          SHARE = NO
        INIT = SWITCH(1) LOC(9 10) 01
    CHOICE = "DMA 7"
      LINK
        DMA = 7
          SHARE = NO
        INIT = SWITCH(1) LOC(9 10) 00

  SUBFUNCTION = "Adapter Ring Speed"
    TYPE = "SPD"
    COMMENTS = "\nThe Token ring Network 16/4 Adapter II
                can operate at either 4 or 16 Mbps ring speed. The adapter
                ring speed MUST match the Token ring Network.\n
                Select the appropriate function within the EISA
                Configuration Utility to display the switch setting(s)."

    CHOICE = "4 Mbps"
    SUBTYPE = "4"
      FREE
        INIT = SWITCH(1) LOC(11) 1
    CHOICE = "16 Mbps"
    SUBTYPE = "16"
      FREE
        INIT = SWITCH(1) LOC(11) 0

  SUBFUNCTION = "Cable Type"
    TYPE = "SPD"
    COMMENTS = "\nThe Token ring Network 16/4 Adapter II
                can operate either using Shielded Twisted Pair cable or
                Unshielded Twisted Pair cable .\n
                Select the appropriate function within the EISA
                Configuration Utility to display the switch setting(s)."

    CHOICE = "STP Type"
    SUBTYPE = "STP"
      FREE
        INIT = SWITCH(1) LOC(12) 1

    CHOICE = "UTP Type"
    SUBTYPE = "UTP"
      FREE
        INIT = SWITCH(1) LOC(12) 0

[ RETURN TO DIRECTORY ]