Metropoli BBS
VIEWER: !isab701.cfg MODE: TEXT (ASCII)
BOARD  ;12/19 gha New - 08/30/93 tmt Added new IO Addrs. and IRQ sel.
 ID="ISAB701"
 NAME="Iomega PC2 SCSI Adapter Boards"
 MFR="Iomega Corporation"
 CATEGORY="OTH"
 SLOT=ISA8 
 LENGTH=140
 COMMENTS="The PC2 is an 8-bit SCSI adapter for use primarily with Iomega \n
           devices. \n
           Please refer to your users manual for more detail."
 VERSION = 1.0
 HELP="Use the V)iew D)etail by Slot mode to see Configuration Options.
 Use E)dit Change F)unction to select Options.
 Use E)dit Change R)esources to define Options."

SWITCH(1)=8
 NAME="SWITCH(1)"
 STYPE=DIP
 VERTICAL=NO
 REVERSE=YES
 LABEL=LOC(1-8) "1" "2" "3" "4" "5" "6" "7" "8"
 FACTORY=LOC(1-8) 11010000
 
JUMPER(1)=4
 NAME="JUMPER(1)"
 JTYPE=TRIPOLE
 VERTICAL=NO
 REVERSE=YES
 LABEL=LOC(1-4) "1" "2" "3" "4"
 FACTORY=LOC(1-4) 1100

SOFTWARE(1)=
 "Match your device drivers with these selected options:"

FUNCTION="Iomega PC2 SCSI Adapter Boards"
 TYPE="OTH"
 HELP="
 Use E)dit Change F)unction to select Options."
 SUBFUNCTION="I/O Port Address"
 CHOICE="340H-345H"
  LINK
   PORT = 340h-345h
   INIT = SWITCH(1) LOC(1 2 5) 110
   INIT = SOFTWARE(1) "I/O Adr 340-345h"
 CHOICE="350H-355H"
  LINK
   PORT = 350H-355H
   INIT = SWITCH(1) LOC(1 2 5) 010
   INIT = SOFTWARE(1) "I/O Adr 350-355h"
 CHOICE="360H-365H"
  LINK
   PORT = 360H-365H
   INIT = SWITCH(1) LOC(1 2 5) 100
   INIT = SOFTWARE(1) "I/O Adr 360-365h"
 CHOICE="370H-375H"
  LINK
   PORT = 370H-375H
   INIT = SWITCH(1) LOC(1 2 5) 000
   INIT = SOFTWARE(1) "I/O Adr 370-375h"
 CHOICE="348H-353H"
  LINK
   PORT = 348h-353h
   INIT = SWITCH(1) LOC(1 2 5) 111
   INIT = SOFTWARE(1) "I/O Adr 348-353h"
 CHOICE="358H-363H"
  LINK
   PORT = 358H-363H
   INIT = SWITCH(1) LOC(1 2 5) 011
   INIT = SOFTWARE(1) "I/O Adr 358-363h"
 CHOICE="368H-373H"
  LINK
   PORT = 368H-373H
   INIT = SWITCH(1) LOC(1 2 5) 101
   INIT = SOFTWARE(1) "I/O Adr 368-373h"
 CHOICE="378H-383H"
  LINK
   PORT = 378H-383H
   INIT = SWITCH(1) LOC(1 2 5) 001
   INIT = SOFTWARE(1) "I/O Adr 378-383h"
 SUBFUNCTION="Direct Memory Access"
 CHOICE = "DMA Enabled"
  LINK
   DMA = 3 | 1
   INIT = SWITCH(1) LOC(3-4) 00 | 10
   INIT = SOFTWARE(1) "DMA CHANNEL 3" | "DMA CHANNEL 1"
 CHOICE = "DMA Disabled"
  FREE
   INIT = SWITCH(1) LOC(3-4) 01
   INIT = SOFTWARE(1) "NO DMA"
 SUBFUNCTION="ROM Address"
 CHOICE = "ROM Enabled"
  COMBINE
   MEMORY=8K
   ADDRESS=
    0CE000h | 0C8000h | 0CA000h | 0CC000h |
    0D0000h | 0D2000h | 0D4000h | 0D6000h |
    0D8000h | 0DA000h | 0DC000h | 0DE000h |
    0E0000h | 0E2000h | 0E4000h
   MEMTYPE=OTH
   INIT=JUMPER(1) LOC(1-4)
    1100 | 1111 | 1110 | 1101 |
    1011 | 1010 | 1001 | 1000 |
    0111 | 0110 | 0101 | 0100 |
    0011 | 0010 | 0001
   INIT=SOFTWARE(1)
    "MEM Adr CE000" | "MEM Adr C8000" | "MEM Adr CA000" | "MEM Adr CC000" |
    "MEM Adr D0000" | "MEM Adr D2000" | "MEM Adr D4000" | "MEM Adr D6000" |
    "MEM Adr D8000" | "MEM Adr DA000" | "MEM Adr DC000" | "MEM Adr DE000" |
    "MEM Adr E0000" | "MEM Adr E2000" | "MEM Adr E4000"
 CHOICE = "ROM Disabled"
  FREE
   INIT=JUMPER(1) LOC(1-4)
    0000
   INIT=SOFTWARE(1)
    "ROM Disabled"
 SUBFUNCTION="IRQ Selection"
 COMMENTS="IRQ is not used by Iomega DOS drivers. \n
          See Manual for more information. "
 CHOICE = "IRQ5"
  LINK
   IRQ = 5 
   INIT = SWITCH(1) LOC(6) 0 
   INIT = SOFTWARE(1) "IRQ5"
 CHOICE = "IRQ7"
  LINK
   IRQ = 7 
   INIT = SWITCH(1) LOC(6) 1 
   INIT = SOFTWARE(1) "IRQ7"

[ RETURN TO DIRECTORY ]