Metropoli BBS
VIEWER: !int0701.cfg MODE: TEXT (CP437)
;╔═════════════════════════════════════════════════════════════════╗
;║                                                                 ║
;║         Intel TokenExpress(tm) ISA 16/4 Network Adapter         ║
;║            Adapter Configuration File   Version 1.30            ║
;║                 Copyright (C) 1992, Intel Corp.                 ║
;║                                                                 ║
;╚═════════════════════════════════════════════════════════════════╝

BOARD
  ID = "INT0701"
  NAME = "Intel TokenExpress(tm) ISA 16/4 Network Adapter"
  MFR = "Intel"
  CATEGORY = "NET"
  SLOT = ISA8OR16
  LENGTH = 167
  AMPERAGE = 1100
  SKIRT = NO
  READID = NO
  BUSMASTER = 1
  IOCHECK = INVALID
  DISABLE = UNSUPPORTED

  COMMENTS = "\nThis is the Intel TokenExpress(tm) 16/4 ISA
              adapter, a high performance Token-Ring adapter for
              ISA and EISA bus computers.  This adapter can operate
	      on networks having a ring speed of either 4 Mbps or
              16 Mbps.\n\n
              This configuration program will note which switch settings
              are already in use by other devices in this computer and
              suggest a configuration for the TokenExpress adapter based
              on the available options.  Be sure to use these settings
              when manually configuring your adapter."

SWITCH(1) = 2
  NAME = "SW1 Ring Speed switch"
  STYPE = SLIDE
  VERTICAL = NO
  REVERSE = YES
  LABEL	= LOC(1 2) "16" "4"
  FACTORY = LOC(1 2) 01
  COMMENTS = "This is the 2-position Ring Speed switch."

SWITCH(2) = 12
  NAME = "SW2 Config. switch"
  STYPE = DIP
  VERTICAL = NO
  REVERSE = NO
  LABEL	= LOC(1-12) "EN" "17" "16" "15" "14" "13"
                    "I1" "I0" "A1" "A0" "D1" "D0"
  FACTORY = LOC(1-12) 111001110011
  COMMENTS = "This is the 12-position configuration dip-switch.
              Please refer to your Intel TokenExpress installation
	      guide for an explanation of the switch settings."

FUNCTION = "Token-Ring Network Adapter"
  TYPE = "NET,TOK"
  CONNECTION = "9-Pin D-Socket: Token-Ring Shielded Twisted
                Pair (Type 1) Lobe Cable"

  SUBFUNCTION = "I/O Address Location"
    COMMENTS = "\nA maximum of four Intel TokenExpress adapters
                may be installed in this computer.  Each adapter must
                use one of the four I/O port address combinations.
                (Each combination consists of two address ranges).\n\n
                Use this program's switch viewing function
                to display the required switch settings."

    CHOICE = "0 =  0A20-0A23 & 0A30-0A3F"
      FREE
        PORT = 0A20h-0A23h
          SHARE = NO
          SIZE = BYTE
      FREE
        PORT = 0A30h-0A3Fh
          SHARE = NO
          SIZE = BYTE
        INIT = SWITCH(2) LOC(9 10) 00
	INIT = PORTADR(0A38h) 11111111
	INIT = PORTADR(0A38h) 00101110
    CHOICE = "1 =  0A24-0A27 & 0A40-0A4F"
      FREE
        PORT = 0A24h-0A27h
          SHARE = NO
          SIZE = BYTE
      FREE
        PORT = 0A40h-0A4Fh
          SHARE = NO
          SIZE = BYTE
        INIT = SWITCH(2) LOC(9 10) 10
	INIT = PORTADR(0A48h) 11111111
	INIT = PORTADR(0A48h) 00101110
    CHOICE = "2 =  0A50-0A53 & 0A60-0A6F"
      FREE
        PORT = 0A50h-0A53h
          SHARE = NO
          SIZE = BYTE
      FREE
        PORT = 0A60h-0A6Fh
          SHARE = NO
          SIZE = BYTE
        INIT = SWITCH(2) LOC(9 10) 01
	INIT = PORTADR(0A68h) 11111111
	INIT = PORTADR(0A68h) 00101110
    CHOICE = "3 =  0A54-0A57 & 0A70-0A7F"
      FREE
        PORT = 0A54h-0A57h
          SHARE = NO
          SIZE = BYTE
      FREE
        PORT = 0A70h-0A7Fh
          SHARE = NO
          SIZE = BYTE
        INIT = SWITCH(2) LOC(9 10) 11
	INIT = PORTADR(0A78h) 11111111
	INIT = PORTADR(0A78h) 00101110

  SUBFUNCTION = "Ring Speed"
    TYPE = "SPD"
    COMMENTS = "\nThis TokenExpress adapter can operate
                at two different ring speeds, 4 Mbps or 16 Mbps.
                You MUST set the adapter's ring speed to match
                the speed of the network to which it is connected.\n\n
                Use this program's switch viewing function
                to display the required switch settings."

    CHOICE = "4 Mbps"
    SUBTYPE = "4"
      FREE
        INIT = SWITCH(1) LOC(1 2) 01
    CHOICE = "16 Mbps" 
    SUBTYPE = "16"
      FREE
        INIT = SWITCH(1) LOC(1 2) 10

  SUBFUNCTION = "RPL PROM Address Location"
    COMMENTS = "\nThere are 12 possible 8K blocks of PC memory
                that can be assigned for the RPL PROM area.
                The recommended address location is CC000-CDFFF.\n\n
                Use this program's switch viewing function
                to display the required switch settings."

    CHOICE = "RPL PROM Disabled"
      LINK
        INIT = SWITCH(2) LOC(1-6) 111001
    CHOICE = "CC000-CDFFF"
      LINK
        MEMORY = 8K
          ADDRESS = 0CC000h
          WRITABLE = NO
          SIZE = BYTE
        INIT = SWITCH(2) LOC(1-6) 011001
    CHOICE = "CE000-CFFFF"
      LINK
        MEMORY = 8K
          ADDRESS = 0CE000h
          WRITABLE = NO
          SIZE = BYTE
        INIT = SWITCH(2) LOC(1-6) 011000
    CHOICE = "D0000-D1FFF"
      LINK
        MEMORY = 8K
          ADDRESS = 0D0000h
          WRITABLE = NO
          SIZE = BYTE
        INIT = SWITCH(2) LOC(1-6) 010111
    CHOICE = "D2000-D3FFF"
      LINK
        MEMORY = 8K
          ADDRESS = 0D2000h
          WRITABLE = NO
          SIZE = BYTE
        INIT = SWITCH(2) LOC(1-6) 010110
    CHOICE = "D4000-D5FFF"
      LINK
        MEMORY = 8K
          ADDRESS = 0D4000h
          WRITABLE = NO
          SIZE = BYTE
        INIT = SWITCH(2) LOC(1-6) 010101
    CHOICE = "D6000-D7FFF"
      LINK
        MEMORY = 8K
          ADDRESS = 0D6000h
          WRITABLE = NO
          SIZE = BYTE
        INIT = SWITCH(2) LOC(1-6) 010100
    CHOICE = "D8000-D9FFF"
      LINK
        MEMORY = 8K
          ADDRESS = 0D8000h
          WRITABLE = NO
          SIZE = BYTE
        INIT = SWITCH(2) LOC(1-6) 010011
    CHOICE = "DA000-DBFFF"
      LINK
        MEMORY = 8K
          ADDRESS = 0DA000h
          WRITABLE = NO
          SIZE = BYTE
        INIT = SWITCH(2) LOC(1-6) 010010
    CHOICE = "DC000-DDFFF"
      LINK
        MEMORY = 8K
          ADDRESS = 0DC000h
          WRITABLE = NO
          SIZE = BYTE
        INIT = SWITCH(2) LOC(1-6) 010001
    CHOICE = "DE000-DFFFF"
      LINK
        MEMORY = 8K
          ADDRESS = 0DE000h
          WRITABLE = NO
          SIZE = BYTE
        INIT = SWITCH(2) LOC(1-6) 010000
    CHOICE = "C8000-C9FFF"
      LINK
        MEMORY = 8K
          ADDRESS = 0C8000h
          WRITABLE = NO
          SIZE = BYTE
        INIT = SWITCH(2) LOC(1-6) 011011
    CHOICE = "CA000-CBFFF"
      LINK
        MEMORY = 8K
          ADDRESS = 0CA000h
          WRITABLE = NO
          SIZE = BYTE
        INIT = SWITCH(2) LOC(1-6) 011010

  SUBFUNCTION = "Interrupt Level"
    TYPE = "INT"
    COMMENTS = "\nThis TokenExpress adapter can be set to any
                of four interrupt levels: 2 (9), 3, 10, or 11.
                The recommended interrupt level is 2 (9).\n
                Please note that the adapter only uses edge-triggered
                interrupts.\n\n
                Use this program's switch viewing function
                to display the required switch settings."

    CHOICE = "Interrupt 2 (9)"
    SUBTYPE = "9"
      LINK
        IRQ = 9
          SHARE = NO
          TRIGGER = EDGE
        INIT = SWITCH(2) LOC(7 8) 11
    CHOICE = "Interrupt 3"
    SUBTYPE = "3"
      LINK
        IRQ = 3
          SHARE = NO
          TRIGGER = EDGE
        INIT = SWITCH(2) LOC(7 8) 10
    CHOICE = "Interrupt 10"
    SUBTYPE = "10"
      LINK
        IRQ = 10
          SHARE = NO
          TRIGGER = EDGE
        INIT = SWITCH(2) LOC(7 8) 01
    CHOICE = "Interrupt 11"
    SUBTYPE = "11"
      LINK
        IRQ = 11
          SHARE = NO
          TRIGGER = EDGE
        INIT = SWITCH(2) LOC(7 8) 00

  SUBFUNCTION = "Data Transfer Mode"
    TYPE = "DMA"
    COMMENTS = "\nThis TokenExpress adapter can utilize any of
                the three available DMA channels: 5, 6 or 7 as a Bus
                Master. The recommended DMA channel is 5.\n
                The programmed I/O transfer mode can be used as an
                alternative to the Bus Master mode.\n
                Use this program's switch viewing function
                to display the required switch settings."

    CHOICE = "Bus master - DMA level 5"
    SUBTYPE = "Master5"
      LINK
        DMA = 5
          SHARE = NO
          TIMING = DEFAULT
        INIT = SWITCH(2) LOC(11 12) 11
    CHOICE = "Bus master - DMA level 6"
    SUBTYPE = "Master6"
      LINK
        DMA = 6
          SHARE = NO
          TIMING = DEFAULT
        INIT = SWITCH(2) LOC(11 12) 10
    CHOICE = "Bus master - DMA level 7"
    SUBTYPE = "Master7"
      LINK
        DMA = 7
          SHARE = NO
          TIMING = DEFAULT
        INIT = SWITCH(2) LOC(11 12) 01
    CHOICE = "Programmed I/O transfer"
    SUBTYPE = "PIO"
      LINK
        INIT = SWITCH(2) LOC(11 12) 00
[ RETURN TO DIRECTORY ]