BOARD
     ID          = "ICU1200"
     NAME        = "easyCACHE SCSI/easyCACHEPro SCSI"
     MFR         = "Perceptive Solutions, Inc."
     CATEGORY    = "MSD"
     SLOT        = ISA16
     VERSION = 3.0

SWITCH(1) = 12
     NAME = "SW1"
     sTYPE = DIP
     VERTICAL = NO
     LABEL = LOC(1-12) "1" "2" "3" "4"  "5"  "6" "7" "8" "9" "10" "11" "12"
     FACTORY = LOC(1-12) 100000000x01

FUNCTION = "SCSI Controller"
  TYPE = "SCS"
  SUBFUNCTION = "BIOS Address"
     CHOICE = "D8000"
       FREE
       MEMORY = 32K
       ADDRESS = 0D8000H 
       WRITABLE = NO
       MEMTYPE = OTH
       SHARE = NO
       INIT = SWITCH(1) LOC(1 2) 10
     CHOICE = "C8000"
       FREE
       MEMORY = 32K
       ADDRESS = 0C8000H 
       WRITABLE = NO
       MEMTYPE = OTH
       SHARE = NO
       INIT = SWITCH(1) LOC(1 2) 00
     CHOICE = "D0000"
       FREE
       MEMORY = 32K
       ADDRESS = 0D0000H 
       WRITABLE = NO
       MEMTYPE = OTH
       SHARE = NO
       INIT = SWITCH(1) LOC(1 2) 01
    CHOICE = "Disabled"
       DISABLE = YES
       FREE
       INIT = SWITCH(1) LOC(1 2) 11       


  SUBFUNCTION = "Hard Drive Port Addres"
     CHOICE = "1F0-1F7,3F0-3F1,3F7"
       COMBINE
       PORT = 01F0H-01F7H 
       COMBINE
       PORT = 03F0H-03F1H 
       COMBINE 
       PORT = 03F7H
       INIT = SWITCH(1) LOC(3) 0
     CHOICE = "170-177,370-371,377"
       COMBINE
       PORT = 0170H-0177H 
       COMBINE 
       PORT = 0370H-0371H 
       COMBINE 
       PORT= 0377H
       INIT = SWITCH(1) LOC(3) 1

  SUBFUNCTION = "Termination Power"
     CHOICE = "Enabled"
       FREE
       INIT = SWITCH(1) LOC(12) 1
     CHOICE = "Disabled"
       DISABLE = YES
       FREE
       INIT = SWITCH(1) LOC(12) 0     

FUNCTION = "Floppy Controller"
  TYPE = "FDC"
  SUBFUNCTION = "Floppy Drive"
     CHOICE = "3F0-3F7"
       FREE
       PORT = 03F0H-03F7H
	   FREE
	   IRQ = 6
	   FREE
	   DMA = 2
     CHOICE = "370-377"
       FREE
       PORT = 0370H-0377H
	   FREE
	   IRQ = 6
	   FREE
	   DMA = 2
	CHOICE = "Disabled"
		DISABLE = YES 

  SUBFUNCTION = "Floppy speed"
     CHOICE = "Single speed"
       FREE
       INIT = SWITCH(1) LOC(5) 0
     CHOICE = "Dual speed"
       FREE
       INIT = SWITCH(1) LOC(5) 1

FUNCTION = "IRQ"
  TYPE = "OTH"
     CHOICE = "IRQ14"
       FREE
       IRQ = 14
       INIT = SWITCH(1) LOC(6-9) 0010     
     CHOICE = "IRQ5"
       FREE
       IRQ = 5
       INIT = SWITCH(1) LOC(6-9) 0000
     CHOICE = "IRQ12"
       FREE
       IRQ = 12
       INIT = SWITCH(1) LOC(6-9) 0100
     CHOICE = "IRQ15"
       FREE
       IRQ = 15
       INIT = SWITCH(1) LOC(6-9) 0001

FUNCTION = "hSOS Load"
  TYPE = "OTH"
     CHOICE = "Enabled"
       FREE
       INIT = SWITCH(1) LOC(11) 0
     CHOICE = "Disabled"
       DISABLE = YES
       FREE
       INIT = SWITCH(1) LOC(11) 1     
[ RETURN TO DIRECTORY ]