Metropoli BBS
VIEWER: !icu0970.cfg MODE: TEXT (ASCII)
BOARD
     ID          = "ICU0970"
     NAME        = "CMS Enhancement Universal AT/XT Controller"
     MFR         = "CMS Enhancement"
     CATEGORY    = "MSD"
     SLOT        = ISA16
     COMMENTS    = "Hard Drives Supported: One XT interface (IDE) drive\n
                    Floppy Drives Supported: None"
     VERSION = 3.0

SWITCH(1) = 8
     NAME = "SW1"
     STYPE = DIP
     VERTICAL = YES
     LABEL = LOC(1-8) "1" "2" "3" "4" "5" "6" "7" "8"
     FACTORY = LOC(1-8) 00110011

FUNCTION = "IDE Controller"
  TYPE = "IDE"
  SUBFUNCTION = "BIOS Address"
     CHOICE = "C8000"
       FREE
       MEMORY = 16K
       ADDRESS = 0C8000H 
       WRITABLE = NO
       MEMTYPE = OTH
       SHARE = NO
       INIT = SWITCH(1) LOC(5 6) 00
     CHOICE = "D8000"
       FREE
       MEMORY = 16K
       ADDRESS = 0D8000H 
       WRITABLE = NO
       MEMTYPE = OTH
       SHARE = NO
       INIT = SWITCH(1) LOC(5 6) 01
     CHOICE = "CC000"
       FREE
       MEMORY = 16K
       ADDRESS = 0CC000H
       WRITABLE = NO
       MEMTYPE = OTH
       SHARE = NO
       INIT = SWITCH(1) LOC(5 6) 10
     CHOICE = "DC000"
       FREE
       MEMORY = 16K
       ADDRESS = 0DC000H 
       WRITABLE = NO
       MEMTYPE = OTH
       SHARE = NO
       INIT = SWITCH(1) LOC(5 6) 11

  SUBFUNCTION = "Hard Drive Controller"
     CHOICE = "Enabled"
       FREE
       INIT = SWITCH(1) LOC(3) 1
     CHOICE = "Disabled"
       DISABLE = YES
       FREE
       INIT = SWITCH(1) LOC(3)0

  SUBFUNCTION = "Attached Drive"
     CHOICE = "Drive C"
       FREE
       INIT = SWITCH(1) LOC(4) 1
     CHOICE = "Drive D"
       FREE
       INIT = SWITCH(1) LOC(4) 0

  SUBFUNCTION = "Hard Drive Port Address"
     CHOICE = "1F0-1F7"
       FREE
       PORT = 01F0H-01F7H
       INIT = SWITCH(1) LOC(7) 1
     CHOICE = "170-177"
       FREE
       PORT = 0170H-0177H
       INIT = SWITCH(1) LOC(7) 1

  SUBFUNCTION = "Interrupt Request"
     CHOICE = "IRQ14"
       FREE
       IRQ = 14
       INIT = SWITCH(1) LOC(8) 1
     CHOICE = "IRQ11"
       FREE
       IRQ = 11
       INIT = SWITCH(1) LOC(8) 0
     CHOICE = "Disabled"
       DISABLE = YES
[ RETURN TO DIRECTORY ]