Metropoli BBS
VIEWER: !hwp1820.cfg MODE: TEXT (ASCII)
; 
; Hewlett-Packard EtherTwist Adapter Card/8 Version 2.00
; Configuration file version 2.00
; !HWP1820.CFG  10-02-1991
;
; (C)Copyright Hewlett-Packard Co., 1989-1991
;    All Rights Reserved.
;

BOARD
   ID       = "hwp1820"
   NAME     = "HP EtherTwist Adapter Card/8 (27245-60002)"
   MFR      = "Hewlett-Packard Co."
   CATEGORY = "NET"
   SLOT     = ISA8
   LENGTH   = 110
   COMMENTS = "The HP EtherTwist PC adapter card is a type 10BASE-T
               compatible local area networking card."

SWITCH(1) = 16
   NAME = "LB, ADDR"
   STYPE = ROTARY
   REVERSE = YES
   LABEL = LOC(1-16) "0" "1" "2" "3" "4" "5" "6" "7" "8" "9" "A" "B" "C" "D" "E" "F"
   FACTORY = LOC(1-16) 1000000000000000

   COMMENTS = "Switch 1 selects both Linkbeat (LB),\n
	       ON or OFF, and I/O Base Address (ADDR)\n
	       according to the table below:\n\n
	       Pos      LB        ADDR\n\n
               0        ON        300h   (Default)\n
               1        ON        340h\n
               2        ON        320h\n
               3        ON        300h\n
               4        ON        2C0h\n
               5        ON        280h\n
               6        ON        240h\n
               7        ON        200h\n
               8        OFF       300h\n
               9        OFF       340h\n
               A        OFF       320h\n
               B        OFF       300h\n
               C        OFF       2C0h\n
               D        OFF       280h\n
               E        OFF       240h\n
               F        OFF       200h\n"


SOFTWARE(1) = "
 Your network software may ask you for this data:"

FUNCTION = "EtherTwist Adapter Card/8 (27245-60002)"
   TYPE = "NET"
   CONNECTION  = "One modular 8-pin LAN connector, and\n
                  one modular 6-pin phone connector"

   SUBFUNCTION = "Linkbeat, I/O Base Address"
      CHOICE = "ON, 300h"
         LINK
       INIT = SWITCH(1) LOC(1-16) 1000000000000000
            INIT = SOFTWARE(1) "I/O Base=300h"
            PORT = 300h
      CHOICE = "ON, 300h - (Duplicates prior Choice)"
         LINK
       INIT = SWITCH(1) LOC(1-16) 0001000000000000
            INIT = SOFTWARE(1) "I/O Base=300h"
            PORT = 300h
      CHOICE = "ON, 340h"
         LINK
       INIT = SWITCH(1) LOC(1-16) 0100000000000000
            INIT = SOFTWARE(1) "I/O Base=340h"
            PORT = 340h
      CHOICE = "ON, 240h"
         LINK
       INIT = SWITCH(1) LOC(1-16) 0000001000000000
            INIT = SOFTWARE(1) "I/O Base=240h"
            PORT = 240h
      CHOICE = "ON, 200h"
         LINK
       INIT = SWITCH(1) LOC(1-16) 0000000100000000
            INIT = SOFTWARE(1) "I/O Base=200h"
            PORT = 200h
      CHOICE = "ON, 280h - Don't use with Novell Netware"
         LINK
       INIT = SWITCH(1) LOC(1-16) 0000010000000000
            INIT = SOFTWARE(1) "I/O Base=280h"
            PORT = 280h
      CHOICE = "ON, 2C0h - Don't use with Novell Netware"
         LINK
       INIT = SWITCH(1) LOC(1-16) 0000100000000000
            INIT = SOFTWARE(1) "I/O Base=2C0h"
            PORT = 2C0h
      CHOICE = "ON, 320h - Don't use with Novell Netware or HP Vectra CS"
         LINK
       INIT = SWITCH(1) LOC(1-16) 0010000000000000
            INIT = SOFTWARE(1) "I/O Base=320h"
            PORT = 320h
      CHOICE = "OFF, 300h"
         LINK
       INIT = SWITCH(1) LOC(1-16) 0000000010000000
            INIT = SOFTWARE(1) "I/O Base=300h"
            PORT = 300h
      CHOICE = "OFF, 300h - (Duplicates prior Choice)"
         LINK
       INIT = SWITCH(1) LOC(1-16) 0000000000010000
            INIT = SOFTWARE(1) "I/O Base=300h"
            PORT = 300h
      CHOICE = "OFF, 340h"
         LINK
       INIT = SWITCH(1) LOC(1-16) 0000000001000000
            INIT = SOFTWARE(1) "I/O Base=340h"
            PORT = 340h
      CHOICE = "OFF, 240h"
         LINK
       INIT = SWITCH(1) LOC(1-16) 0000000000000010
            INIT = SOFTWARE(1) "I/O Base=240h"
            PORT = 240h
      CHOICE = "OFF, 200h"
         LINK
       INIT = SWITCH(1) LOC(1-16) 0000000000000001
            INIT = SOFTWARE(1) "I/O Base=200h"
            PORT = 200h
      CHOICE = "OFF, 280h - Don't use with Novell Netware"
         LINK
       INIT = SWITCH(1) LOC(1-16) 0000000000000100
            INIT = SOFTWARE(1) "I/O Base=280h"
            PORT = 280h
      CHOICE = "OFF, 2C0h - Don't use with Novell Netware"
         LINK
       INIT = SWITCH(1) LOC(1-16) 0000000000001000
            INIT = SOFTWARE(1) "I/O Base=2C0h"
            PORT = 2C0h
      CHOICE = "OFF, 320h - Don't use with Novell Netware or HP Vectra CS"
         LINK
       INIT = SWITCH(1) LOC(1-16) 0000000000100000
            INIT = SOFTWARE(1) "I/O Base=320h"
            PORT = 320h

   SUBFUNCTION = "Interrupt Channel (IRQ)"
      CHOICE = "3"
         LINK
            INIT = Software(1) "IRQ=3"
            IRQ = 3
      CHOICE = "4"
         LINK
            INIT = Software(1) "IRQ=4"
            IRQ = 4
      CHOICE = "5"
         LINK
            INIT = Software(1) "IRQ=5"
            IRQ = 5
      CHOICE = "7"
         LINK
            INIT = Software(1) "IRQ=7"
            IRQ = 7


[ RETURN TO DIRECTORY ]