Metropoli BBS
VIEWER: !dec8300.cfg MODE: TEXT (ASCII)
BOARD			; 2/4/91
 ID="DEC8300"
 NAME="DEC DEPCA LC Ethernet Controller"
 MFR="DEC"
 CATEGORY="NET"
 SLOT=ISA8
 LENGTH=330
 COMMENTS="Digital Equipment Corporation\n
           DEPCA LC Ethernet Controller\n
	   EISA Configuration Options List."

SWITCH(1)=12
 NAME="Dip Switches"
 STYPE=DIP
 VERTICAL = YES
 REVERSE = YES
 FACTORY=LOC(1-12) 111111000010

FUNCTION="Memory Address Range and Size Selection."

 CHOICE="64 KB Range D0000-DFFFF"
 LINK
  MEMORY=64K
  ADDRESS=0D0000h
  MEMTYPE=OTH
  INIT=SWITCH(1) LOC(1-4) 1111

 CHOICE="64 KB Range C0000-CFFFF"
 LINK
  MEMORY=64K
  ADDRESS=0C0000h
  MEMTYPE=OTH
  INIT=SWITCH(1) LOC(1-4) 0111

 CHOICE="64 KB Range E0000-EFFFF"
 HELP="\tSome PCs do not support the E0000-EFFFF memory address range.\n
        Check your PC manual for this information."
 LINK
  MEMORY=64K
  ADDRESS=0E0000h
  MEMTYPE=OTH
  INIT=SWITCH(1) LOC(1-4) 0011

 CHOICE="32 KB Range C8000-CFFFF"
 LINK
  MEMORY=32K
  ADDRESS=0C8000h
  MEMTYPE=OTH
  INIT=SWITCH(1) LOC(1-4) 0101

 CHOICE="32 KB Range D8000-DFFFF"
 LINK
  MEMORY=32K
  ADDRESS=0D8000h
  MEMTYPE=OTH
  INIT=SWITCH(1) LOC(1-4) 1101


 CHOICE="32 KB Range E8000-EFFFF"
 HELP="\tSome PCs do not support the E8000-EFFFF memory address range.\n
        Check your PC manual for this information."
 LINK
  MEMORY=32K
  ADDRESS=0E8000h
  MEMTYPE=OTH
  INIT=SWITCH(1) LOC(1-4) 0001

FUNCTION="I/O Address Selection"

 CHOICE="300h-30Fh"
 LINK
  PORT=300h-30Fh
  INIT=SWITCH(1) LOC(5) 1

 CHOICE="200h-20Fh"
 LINK
  PORT=200h-20Fh
  INIT=SWITCH(1) LOC(5) 0

FUNCTION="Remote Boot Selection"

  CHOICE="Remote Boot Disabled"
  LINK
   INIT=SWITCH(1) LOC(6) 1

 CHOICE="Remote Boot Enabled with timeout set to 30 seconds."
 HELP="The Remote boot ROM must be installed in order for this to work."
 LINK
  INIT=SWITCH(1) LOC(6-7) 00

 CHOICE="Remote Boot Enabled with timeout set to 150 seconds."
 HELP="The Remote boot ROM must be installed in order for this to work."
 LINK
  INIT=SWITCH(1) LOC(6-7) 01

FUNCTION="Interrupt Request Line Selection"

 CHOICE="IRQ5"
 LINK
  IRQ=5
  INIT=SWITCH(1) LOC(8-12) 00010

 CHOICE="IRQ2"
 LINK
  IRQ=2
  INIT=SWITCH(1) LOC(8-12) 10000

 CHOICE="IRQ3"
 LINK
  IRQ=3
  INIT=SWITCH(1) LOC(8-12) 01000

 CHOICE="IRQ4"
 LINK
  IRQ=4
  INIT=SWITCH(1) LOC(8-12) 00100

 CHOICE="IRQ7"
 LINK
  IRQ=7
  INIT=SWITCH(1) LOC(8-12) 00001
[ RETURN TO DIRECTORY ]