Metropoli BBS
VIEWER: @6e79.adf MODE: TEXT (ASCII)
AdapterId 06E79h

AdapterName "IRMA 3 3270 Coax Adapter"

NumBytes 4 

NamedItem
        Prompt "IRMA 3 Adapter Address"
      choice "200h-20Fh"  pos[0]=0000000xb io 0200h-020Fh
      choice "240h-24Fh"  pos[0]=0001000xb io 0240h-024Fh
      choice "260h-26Fh"  pos[0]=0001100xb io 0260h-026Fh
      choice "2E0h-2EFh"  pos[0]=0011100xb io 02E0h-02EFh

   Help
     "This is the IRMA 3 adapter address. Four choices
      are available :
     			200h - 20Fh
     			240h - 24Fh
     			260h - 26Fh
     			2E0h - 2EFh"

NamedItem
        Prompt "IBM Emulator Port Address"
          Choice  "Fixed Resource"
          pos[0]=xxxxxxxxb pos[1]=xx111000b pos[2]=xxxxxx01b io  02D0h - 02DFh

          int 2
          Choice  "Disable IBM"
          pos[0]=xxxxxxxxb pos[2]=xxxxxxx0b

   Help
     "The IBM emulator port Address is fixed at 02D0h - 02DFh and uses
      interrupt 2 and dual port memory at 0CE000 - 0CFFFFh. If these 
      resources conflict with another adapter board in the PC you can: 
      1. Change the resource requirements on the other board to resolve
         the conflict or
      2. Choose 'Disable IBM'. You can not run IBM emulation software
         on IRMA 3 if IBM is disabled."

NamedItem
        Prompt "IRMA Emulator Port Address"
          Choice  "Enable 220-227"
        pos[0] = xxxxxxxxb pos[1]=1xxxxxxxb io 0220h-0227h
          Choice  "Disable 220-227"
        pos[0]=xxxxxxxxb pos[1] = 0xxxxxxxb

   Help

          "The IRMA Emulator port Address is fixed at 220h. If the IRMA 
      Emulator Port address conflicts with another adapter board in the PC 
      you can: 
      1. Change the port address setting on the other board to resolve the 
         conflict or 
      2. Choose 'Disable 220 - 227'. Older DCA emulation software, such as 
         E78, and applications written for the original PROM board IRMA 
         product only run at address 220 - 227. If your software requires 
         this address 'Enable 220 - 227' must be selected. Current DCA 
         emulators, i.e. E78 PLUS, Irmax - Multisession and Irmax - DFT, can 
         be configured to use the three DCA emulator addresses selected below."

NamedItem
        Prompt "IRQ levels and disable interrupt"
      choice "IRQ9 "   pos[1]=xxx11000b int 9
      choice "IRQ10"   pos[1]=xxx11001b int 10
      choice "Disable INT"  pos[1]=xxx0xxxxb

   Help

      "When using IBM emulation software or DCA Irmax - DFT or 
      Irmax - Multisessions, IRQ9 (same as IRQ2) must be selected."

NamedItem
        Prompt "DCA Emulator Address"
      choice "280h-29Fh" pos[1]=x1xxxxxxb pos[2]=100xxxxxb io 0280h-029Fh
      choice "2A0h-2BFh" pos[1]=x1xxxxxxb pos[2]=101xxxxxb io 02A0h-02BFh
      choice "2C0h-2DFh" pos[1]=x1xxxxxxb pos[2]=110xxxxxb io 02C0h-02DFh
      choice  "Disable DCA" pos[1]=x0xxxxxxb

   Help

      "Address 280 - 29F is the recommended setting for use with DCA 
      emulators. If the DCA Emulator Address conflicts with another 
      adapter board in the PC you can :
      1. Change the port address setting on the other board to resolve 
         the conflict or 
      2. Choose one of the two alternate addresses and configure the DCA 
         emulator to use the new address."

NamedItem
        Prompt "RAM Address Range"
  choice "CE000 - CFFFF"
      pos[1]=xx1xxxxxb pos[3]=xx011100b MEM 0CE000h - 0CFFFFh
  choice "Disable RAM"
      pos[1]=xx0xxxxxb pos[3]=xx0000xxb

   Help

      "When using IBM emulation software Ram Address Range 
      CE000 - CFFFF must be selected. If the Ram Address Range 
      conflicts with another adapter in the PC you can : 
      1. Change the ram address setting on the other board to 
         resolve the conflict or
      2. Choose 'Disable Ram'. You can not run IBM emulation 
         software on IRMA 3 if disable ram is selected."
[ RETURN TO DIRECTORY ]