AdapterId 06E79h
AdapterName "IRMA 3 3270 Coax Adapter"
NumBytes 4
NamedItem
Prompt "IRMA 3 Adapter Address"
choice "200h-20Fh" pos[0]=0000000xb io 0200h-020Fh
choice "240h-24Fh" pos[0]=0001000xb io 0240h-024Fh
choice "260h-26Fh" pos[0]=0001100xb io 0260h-026Fh
choice "2E0h-2EFh" pos[0]=0011100xb io 02E0h-02EFh
Help
"This is the IRMA 3 adapter address. Four choices
are available :
200h - 20Fh
240h - 24Fh
260h - 26Fh
2E0h - 2EFh"
NamedItem
Prompt "IBM Emulator Port Address"
Choice "Fixed Resource"
pos[0]=xxxxxxxxb pos[1]=xx111000b pos[2]=xxxxxx01b io 02D0h - 02DFh
int 2
Choice "Disable IBM"
pos[0]=xxxxxxxxb pos[2]=xxxxxxx0b
Help
"The IBM emulator port Address is fixed at 02D0h - 02DFh and uses
interrupt 2 and dual port memory at 0CE000 - 0CFFFFh. If these
resources conflict with another adapter board in the PC you can:
1. Change the resource requirements on the other board to resolve
the conflict or
2. Choose 'Disable IBM'. You can not run IBM emulation software
on IRMA 3 if IBM is disabled."
NamedItem
Prompt "IRMA Emulator Port Address"
Choice "Enable 220-227"
pos[0] = xxxxxxxxb pos[1]=1xxxxxxxb io 0220h-0227h
Choice "Disable 220-227"
pos[0]=xxxxxxxxb pos[1] = 0xxxxxxxb
Help
"The IRMA Emulator port Address is fixed at 220h. If the IRMA
Emulator Port address conflicts with another adapter board in the PC
you can:
1. Change the port address setting on the other board to resolve the
conflict or
2. Choose 'Disable 220 - 227'. Older DCA emulation software, such as
E78, and applications written for the original PROM board IRMA
product only run at address 220 - 227. If your software requires
this address 'Enable 220 - 227' must be selected. Current DCA
emulators, i.e. E78 PLUS, Irmax - Multisession and Irmax - DFT, can
be configured to use the three DCA emulator addresses selected below."
NamedItem
Prompt "IRQ levels and disable interrupt"
choice "IRQ9 " pos[1]=xxx11000b int 9
choice "IRQ10" pos[1]=xxx11001b int 10
choice "Disable INT" pos[1]=xxx0xxxxb
Help
"When using IBM emulation software or DCA Irmax - DFT or
Irmax - Multisessions, IRQ9 (same as IRQ2) must be selected."
NamedItem
Prompt "DCA Emulator Address"
choice "280h-29Fh" pos[1]=x1xxxxxxb pos[2]=100xxxxxb io 0280h-029Fh
choice "2A0h-2BFh" pos[1]=x1xxxxxxb pos[2]=101xxxxxb io 02A0h-02BFh
choice "2C0h-2DFh" pos[1]=x1xxxxxxb pos[2]=110xxxxxb io 02C0h-02DFh
choice "Disable DCA" pos[1]=x0xxxxxxb
Help
"Address 280 - 29F is the recommended setting for use with DCA
emulators. If the DCA Emulator Address conflicts with another
adapter board in the PC you can :
1. Change the port address setting on the other board to resolve
the conflict or
2. Choose one of the two alternate addresses and configure the DCA
emulator to use the new address."
NamedItem
Prompt "RAM Address Range"
choice "CE000 - CFFFF"
pos[1]=xx1xxxxxb pos[3]=xx011100b MEM 0CE000h - 0CFFFFh
choice "Disable RAM"
pos[1]=xx0xxxxxb pos[3]=xx0000xxb
Help
"When using IBM emulation software Ram Address Range
CE000 - CFFFF must be selected. If the Ram Address Range
conflicts with another adapter in the PC you can :
1. Change the ram address setting on the other board to
resolve the conflict or
2. Choose 'Disable Ram'. You can not run IBM emulation
software on IRMA 3 if disable ram is selected."