AdapterId 05127h

AdapterName "Tecmar MCA QIC-02 Host Adapter w/ Data Compression"   

NumBytes 3

NamedItem
        Prompt "I/O Location"
      choice "I/O 300"    pos[0]=XXXX000Xb  io 0300h-030Fh
      choice "I/O 350"    pos[0]=XXXX001Xb  io 0350h-035Fh
      choice "I/O 368"    pos[0]=XXXX010Xb  io 0368h-0377h
      choice "I/O 338"    pos[0]=XXXX011Xb  io 0338h-0347h
      choice "I/O 200"    pos[0]=XXXX100Xb  io 0200h-020Fh
      choice "I/O 238"    pos[0]=XXXX101Xb  io 0238h-0247h
      choice "I/O 310"    pos[0]=XXXX110Xb  io 0310h-031Fh

   Help
 "This port can be assigned to any of seven (7) I/O locations. 
 Use the F5=Previous and the F6=Next keys to change this
 assignment in the 'Change configuration' window.  Conflicting
 assignments are marked with an asterisk and must be changed to
 use the adapter."

NamedItem
        Prompt "Interrupt Number"
      choice "Int  3"   pos[0]=XX00XXXXb  int  3
      choice "Int  4"   pos[0]=XX01XXXXb  int  4
      choice "Int  5"   pos[0]=XX10XXXXb  int  5
      choice "Int  6"   pos[0]=XX11XXXXb  int  6
			     
   Help
      "This assignment need only be changed if you do not wish certain
      programs to share interrupts. Use the F5=Previous and the F6=Next keys
      to change interrupt assignments if you are in the
      'Change configuration' window."

NamedItem
        Prompt "DMA Arbitration (Tape)"
      choice "Level 1"   pos[1]=XXXX0001b  arb  1
      choice "Level 2"   pos[1]=XXXX0010b  arb  2
      choice "Level 3"   pos[1]=XXXX0011b  arb  3
      choice "Level 5"   pos[1]=XXXX0101b  arb  5
      choice "Level 6"   pos[1]=XXXX0110b  arb  6
      choice "Level 7"   pos[1]=XXXX0111b  arb  7
      choice "Level 0"   pos[1]=XXXX0000b  arb  0
      choice "Level 4"   pos[1]=XXXX0100b  arb  4


  Help
      "This assignment need only be changed if it is in conflict
      with another assignment.  Conflicting assignments are marked
      with an asterisk.  Use the F5=Previous and the F6=Next keys
      to change arbitration level assignments if you are in the
      'Change configuration' window."

NamedItem
        Prompt "DMA Arbitration (Comp. 1)"
      choice "Level 1"   pos[2]=0001XXXXb  arb  1
      choice "Level 2"   pos[2]=0010XXXXb  arb  2
      choice "Level 3"   pos[2]=0011XXXXb  arb  3
      choice "Level 5"   pos[2]=0101XXXXb  arb  5
      choice "Level 6"   pos[2]=0110XXXXb  arb  6
      choice "Level 7"   pos[2]=0111XXXXb  arb  7
      choice "Level 0"   pos[2]=0000XXXXb  arb  0
      choice "Level 4"   pos[2]=0100XXXXb  arb  4


  Help
      "This assignment need only be changed if it is in conflict
      with another assignment.  Conflicting assignments are marked
      with an asterisk.  Use the F5=Previous and the F6=Next keys
      to change arbitration level assignments if you are in the
      'Change configuration' window."

NamedItem
        Prompt "DMA Arbitration (Comp. 2)"
      choice "Level 1"   pos[2]=XXXX0001b  arb  1
      choice "Level 2"   pos[2]=XXXX0010b  arb  2
      choice "Level 3"   pos[2]=XXXX0011b  arb  3
      choice "Level 5"   pos[2]=XXXX0101b  arb  5
      choice "Level 6"   pos[2]=XXXX0110b  arb  6
      choice "Level 7"   pos[2]=XXXX0111b  arb  7
      choice "None   "   pos[2]=XXXX1111b
      choice "Level 0"   pos[2]=XXXX0000b  arb  0
      choice "Level 4"   pos[2]=XXXX0100b  arb  4


  Help
      "This assignment need only be changed if it is in conflict
      with another assignment.  Conflicting assignments are marked
      with an asterisk.  Use the F5=Previous and the F6=Next keys
      to change arbitration level assignments if you are in the
      'Change configuration' window."