TR2KDIAG - T1108 16/4 Token-Ring Adapter Diagnostics

Purpose:  TR2KDIAG tests T1108 Token Ring adapters
          and network cable. When an error occurs, possible causes
          and solutions are given to help eliminate the problem.
          You should run TR2KDIAG after installation, repair, or if
          you suspect a problem.

Format:   [d:][path]TR2KDIAG [/p#] [/i#] [/w] [/b] [/s#] [/t] [/a#]

          /p###          Sets the I/O port.  Default: A20
          /i#            Sets the adapter interrupt.  Default: 9
          /w             Sets the adapter to 0 Wait State Pseudo
                         DMA. Default: off
          /b             Sets the adapter to 16 bit Pseudo DMA.
                         Default: 8 bit
          /s##           Sets the adapter speed to the value
                         specified. Default: 16 Mbps
          /t             Runs TR2KDIAG in AUTO TEST mode.
          /a############ Sets the adapter address to the given 12
                         character address.

Note 1:  Unpredictable results will occur if hardware settings
         don't match parameters given on the command line.

Note 2:  Until a command has been issued that initializes the
         adapter, certain data fields displayed may contain zeroes
         or ??? (i.e. Node address, Firmware version and Adapter
         RAM).

Usage:    A menu will appear on the screen.  The options are
          Transmit and Receive Test, Echo Server, Line Monitor,
          Open-Close Test, Switch Display, Memory Test, ROM Test
          and Quit.

          TRANSMIT & RECEIVE
          The Transmit and Receive Test will transmit data packets
          on the network cabling, and check the transmitted and
          received data for errors.  The options available from
          this menu are Internal, Internal Continuous, Echoed,
          Echoed Continuous, and Parameters.

          When Internal or Internal Continuous are selected, the
          adapter transmits packets to itself.  The transmitted and
          received data are compared to verify that no data loss or
          corruption has occurred.

          Echoed and Echoed Continuous are similar to the Internal
          test modes, with the exception that they require another
          station on the network to be operating as an echo server.

          An echo server will receive packets from stations that
          have requested an echo server, and will retransmit the
          packet back to originating station.  To operate a second
          station as an echo server, start TR2KDIAG on the second
          station and select "E" from the main menu.  Then start
          TR2KDIAG on the station to be tested and select the test
          that you wish to run.
          Only one echo server is needed per physical network.

          Both the Echoed and Internal tests verify that the
          adapter transmit and receive hardware are functioning
          properly.  However, echo mode will more thoroughly test
          the network cabling.

          Choosing the Parameters option will bring up a menu that
          will allow you to specify the packet size and test
          pattern for transmit packets.

          LINE MONITOR
          Line Monitor menu displays five options: Internal Test
          Throughput, Echo Test Throughput, Log Errors, Display Log
          Totals and Parameters.

          The throughput tests can be operated in either internal
          or echoed mode (as described for TRANSMIT & RECEIVE).
          Like the transmit and receive tests, the throughput test
          is used to verify the transmit and receive functions of
          the adapter. In addition, this test will calculate and
          display the Kbytes/sec throughput of the adapter. Due to
          data checking and other calculations that are performed
          in the test, the throughput value that is displayed will
          be less than the maximum throughput for the adapter and
          should not be used to determine overall adapter
          performance.

          The Error Log feature is used to capture and display any
          error frames that have been issued by stations on the
          network.  The node address of the station that issued the
          error, and the type of error, will be displayed on the
          screen.  The error information can optionally be written
          to the disk file "TR2KDIAG.LOG".  Once the Error Log has
          been run, the totals for each node can be displayed by
          selecting the Display Log function.

          Choosing the Parameters option will bring up a menu that
          will allow you to specify the packet size and test
          pattern for transmit packets.

          ECHO SERVER
          Choosing the Echo Server option will designate the
          station as an echo server.  When a packet is received
          from another station, an echo server transmits the packet
          back to the packet's originator.  No error checks or
          changes are made to the packet by the echo server.

          OPEN-CLOSE TEST
          The Open-Close Test will repeatedly reset, initialize,
          open and close the adapter until a key is pressed.  This
          causes the adapter to perform its own diagnostics and
          ring insertion tests.  The results of the tests are
          reported to the TR2KDIAG program.

          MEMORY
          The MEMORY option will cause the PC to calculate and
          display the amount of RAM that is installed on the
          adapter.  It will also determine the MAC or LLC revision
          level and the BIA address (unless overridden).

[ RETURN TO DIRECTORY ]