Novell NetWare Server 3.11
--------------------------
For a NetWare 3.11 server configuration, We provides a NetWare Server 3.11 ODI
driver which is included on the NE100TX-E PCI Fast Ethernet Adapter driver
diskette.
Note:
-----
The directory structure provided on the 10/100 Auto PCI Fast Ethernet Adapter
driver diskette has been setup for automatic OEM installation. Also, more
information can be found in the Novell NetWare 3.11 documentation.
Use the (LOAD) and (BIND) commands to load the NetWare 3.11 ODI server driver
as described below. For more information on these commands, refer to the Novell
NetWare 3.11 LAN Driver Installation documentation.
There are two methods for loading the NetWare Server 3.11 driver:
(1) use the server command line prompt (":") or
(2) edit the (AUTOEXEC.NCF) file.
Note:
-----
If you use the server command line, you will need to load the driver each time
the system is booted. If you edit the AUTOEXEC.NCF file, it will automatically
load the driver each time your system is booted.
Follow the steps listed below:
1 Install NetWare 3.11 on your system.
2 Copy the ODI Server driver (NE100TX.LAN) and relative files from the
NE100TX-E PCI Fast Ethernet Adapter driver diskette to the hard
disk directory where the NetWare 3.11 system files are located. The
following path should be used to access the files from the NE100TX-E
PCI Fast Ethernet Adapter driver diskette:
A:\SERVER.ODI\3.11\ne100tx.LAN
A:\SERVER.ODI\3.11\PATCHMAN.NLM
A:\SERVER.ODI\3.11\LSLENH.NLM
A:\SERVER.ODI\3.11\MSM31X.NLM
A:\SERVER.ODI\3.11\ETHERTSM.NLM
A:\SERVER.ODI\3.11\MONITOR.NLM
3 Boot NetWare by executing (SERVER.EXE). Refer to the appropriate
Novell NetWare documentation on loading disk drivers and mounting
volumes for more information.
4 To load the driver manually, follow the steps listed below. If you
want to load the driver using (AUTOEXEC), go to step 5.
Notes:
(1) You will need to specify the DOS path if the driver is located in
a DOS partition.
Type the following command at the file server console :
LOAD PATHCHMAN
LOAD LSLENH
LOAD MSM31X
LOAD ETHERTSM
LOAD ne100tx
Next, press <Enter> to accept the "SLOT=" values which your NE100TX-E
CI Fast Ethernet Adapter is located or make changes for your adapter.
An example with the NE100TX-E PCI Fast Ethernet Adapter:
SLOT = 16
Then, bind the driver to the IPX protocol stack by typing:
BIND IPX TO ne100tx NET=xxxx
(Bind to IPX or any other protocol stack; where e.g., xxxx=1234)
Then press <Enter>.
The installation of the NetWare Server 3.11 driver is now complete.
5 To load the driver using (AUTOEXEC), you must first edit the
(AUTOEXEC.NCF) file.
* Type "LOAD INSTALL" at the server prompt (":") to access the Install
Utility.
* Open the "SYSTEM OPTIONS" menu to access "EDIT AUTOEXEC".
* Then add the following command lines to the (AUTOEXEC.NCF) file.
An example with the NE100TX-E PCI Fast Ethernet Adapter:
LOAD ne100tx FRAME=Ethernet_802.2
BIND IPX TO ne100tx NET=xxxx
(Bind to IPX or any other protocol stack; where e.g., xxxx=1234)
You can load 4 frame type protocol at a time when the server is
booted. To use this option you must load and bind another
frame type protocol( Ethernet_802.3,Ethernet_II,Ethernet_SNAP ).
Loading Multiple NE100TX-E PCI Fast Ethernet Adapters
-------------------------------------------------------
The driver must be loaded again for each new NE100TX-E PCI Fast Ethernet
Adapter installed in the system.
If more than one adapter card will be installed, the user must
specify the board's SLOT number for each Adapter. For example, to load
two NE100TX-E PCI Fast Ethernet Adapters:
LOAD ne100tx
For board 1: load ne100tx SLOT=16
For board 2: load ne100tx SLOT=17
The installation of the NetWare Server 3.11 driver is now complete.
Notes:
(1) You will need to specify the DOS path if the driver is located in
a DOS partition.
Parameters
----------
The following parameters belong on the server's command line, or in
the load line inside the AUTOEXEC.NCF. The general way of using these
parameters is:
LOAD <driver name> <PARAMETER NAME>... <PARAMETER NAME[=VALUE]>
Example:
LOAD <driver name> TP_FULL_DUPLEX SLOT=16 FRAME=Ethernet_802.2
Driver specific parameters list (as for NetWare standard parameters,
please see the NetWare user's manual):
TP_FULL_DUPLEX selects twisted pair connection to work in
full duplex mode.
-------------------------------------[END]--------------------------------------