ISA NE-Series Ethernet Adapter
Power Lan driver Installation
===============================
To install this adapter with Power Lan system, user
can use 3 different methods as following:
A) Install Power Lan driver with the NE-Series adapter
B) Install DOS/ODI drivers for Power Lan
C) Install Packet drivers for Power Lan
A) Install Power Lan Driver with the NE-Series adapter
===================================================
To install Power Lan driver with this adapter
1.) Use Power Lan install program, and select "NE2000" item.
2.) Change Iobase and IRQ setting by 1Step setup program
and using the same port at NXNE2000 command line parameter:
/lp:Iobase /li:IRQ
Example ----- PLSTART.BAT
if %PLTREE%. == . set PLTREE=C:\PL
REM
REM - - - - - - - - - - - - - - - - - - Start NETBIOS - - - - - - - - - - - -
REM
%PLTREE%\PROGRAMS\nxne2000 /ln:0 /ses:14 /nam:17 /lp:300 /li:3
REM
B) Install DOS/ODI driver for Power Lan
=============================================
To install DOS/ODI driver at Power Lan system:
1.) Copy DOS/ODI driver "NWMLID.COM from A:\NETWARE\ODI\DOSODI
to C:\PL\PROGRAMS
2.) Copy Novell's driver "LSL.COM from A:\NETWARE to C:\PL\PROGRAMS
3.) Create NET.CFG file as following example at C:\PL\PROGRAMS
4.) Use Power Lan install program, and select "ODI" item,
then add "LSL.COM" and "NWMLID.COM" before NXODI.EXE
at C:\PL\ADMIN\SYS\PLSTART.BAT's "start NETBIOS" section
Example ----- PLSTART.BAT
if %PLTREE%. == . set PLTREE=C:\PL
REM
REM - - - - - - - - - - - - - - - - - - Start NETBIOS - - - - - - - - - - - -
REM
LSL
%PLTREE%\NWMLID ------> DOS/ODI driver
%PLTREE%\PROGRAMS\nxodi /ln:0 /ses:14 /nam:17
REM
Example ----- NET.CFG
Link Driver NWMLID
Frame ETHERNET_II
Protocol IPX 8137 ETHERNET_II
Port 300
INT 3
C) Install Packet driver for Power Lan
=============================================
To install packet driver at Power Lan system:
1.) Copy packet driver "NWPD.COM" from A:\PKTDRV to
C:\PL\PROGRAMS
2.) Use Power Lan install program, and select "NXPACKET" item,
then add packet driver "NWPD.COM" before NXPACKET.EXE
at C:\PL\ADMIN\SYS\PLSTART.BAT's "start NETBIOS" section
Example ----- PLSTART.BAT
if %PLTREE%. == . set PLTREE=C:\PL
REM
REM - - - - - - - - - - - - - - - - - - Start NETBIOS - - - - - - - - - - - -
REM
%PLTREE%\NWPD 0x60 ------> packet driver
%PLTREE%\PROGRAMS\nxpacket /ln:0 /ses:14 /nam:17 /li:0x60
-- THE END --