Metropoli BBS
VIEWER: !nvl0901.cfg MODE: TEXT (ASCII)
BOARD		 
 ID="NVL0901"
 NAME="Novell NE2100 Ethernet/Cheapernet Adapter"
 MFR="Novell"
 CATEGORY="NET"
 SLOT=ISA16
 LENGTH=158
 AMPERAGE=1229
 COMMENTS="
 \nUse one of the three methods for configuration.
 \nTo select Connector Type and the Wait State Option, use method 3.
 \n1. Select \"Netware Basic Configuration\" for one of eight configuration 
  options available. Four without Remote Boot EPROM and four with Remote Boot 
  EPROM. 
 \n2. Select \"Other Options\".	
 \n3. Select each individual option from the available options listed." 
 HELP="
 Use the V)iew D)etail by Slot mode to see Configuration Options 
 by Network Software Type. Use E)dit Change F)unction to select Options."

JUMPER(1)=4
 JTYPE=paired
 NAME="IRQ"
 LABEL=LOC(4-1) "W21" "W22" "W23" "W24"
 FACTORY=LOC(4-1) 0010

JUMPER(2)=3
 JTYPE=paired
 NAME="Base I/O Addr"
 LABEL=LOC(3-1) "W18" "W19" "W20"
 FACTORY=LOC(3-1) 011

JUMPER(3)=8
 JTYPE=tripole
 NAME="Network Type Jumper"
 LABEL=LOC(8-1) "W2" "W3" "W4" "W5" "W6" "W7" "W8" "W9"
 FACTORY=LOC(8-1) 00000000

JUMPER(4)=4
 JTYPE=paired
 NAME="-DACK"
 LABEL=LOC(4-1) "W10" "W11" "W12" "W13"  
 FACTORY=LOC(4-1) 0100 
 VERTICAL=YES

JUMPER(5)=4
 JTYPE=paired
 NAME="DRQ"
 LABEL=LOC(4-1) "W14" "W15" "W16" "W17" 
 FACTORY=LOC(4-1) 0100 
 VERTICAL=YES

JUMPER(6)=1
 JTYPE=paired
 NAME="Wait State Option"
 LABEL=LOC(1) "W1"
 FACTORY=LOC(1) 0 

SOFTWARE(1)="
 \nThe NE2100 has four preset options numbered 0-3. If one of these 
 \noptions can\'t be used, use one of the other methods of 
 \nconfiguration. Be Sure to Configure Network Server or 
 \nWorkstation Software to Use the Selected Resource Options: \n"
SOFTWARE(2)="Your connection type is: "
SOFTWARE(3)="You have selected:  "
SOFTWARE(4)="Your individually selected IRQ is: "
SOFTWARE(5)="Your individually selected DMA is: "
SOFTWARE(6)="Your individually selected I/O and EPROM Address is: "
SOFTWARE(7)="You have automatically selected:  "

FUNCTION="NE2100"
 TYPE="NET"
 HELP="
 Use E)dit Change F)unction to Select Options.
 \n\nOnly one Network Function Should be in effect."

SUBFUNCTION="NE2100 Basic Configuration"
CHOICE="Config Optn 0:  300,IRQ3,DMA5"
 LINK
 IRQ=3
 INIT=JUMPER(1) LOC(4-1) 0010
 PORT=0300h-0317h
 INIT=JUMPER(2) LOC(3-1) 011
 DMA=5
 TIMING=DEFAULT
 INIT=JUMPER(4) LOC(4-1) 0100
 INIT=JUMPER(5) LOC(4-1) 0100
 INIT=SOFTWARE(1) "300, IRQ3, DMA5"

CHOICE="Config Optn 1:  320,IRQ4,DMA6"
 LINK
 IRQ=4
 INIT=JUMPER(1) LOC(4-1) 0100
 PORT=0320h-0337h
 INIT=JUMPER(2) LOC(3-1) 010
 DMA=6
 TIMING=DEFAULT
 INIT=JUMPER(4) LOC(4-1) 0010
 INIT=JUMPER(5) LOC(4-1) 0010
 INIT=SOFTWARE(1) "320, IRQ4, DMA6"

CHOICE="Config Optn 2:  340,IRQ5,DMA7"
 LINK
 IRQ=5
 INIT=JUMPER(1) LOC(4-1) 1000
 PORT=0340h-0357h
 INIT=JUMPER(2) LOC(3-1) 001
 DMA=7
 TIMING=DEFAULT
 INIT=JUMPER(4) LOC(4-1) 0001
 INIT=JUMPER(5) LOC(4-1) 0001
 INIT=SOFTWARE(1) "340, IRQ5, DMA7"

CHOICE="Config Optn 3:  360,IRQ9,DMA3"
 LINK
 IRQ=9
 INIT=JUMPER(1) LOC(4-1) 0001
 PORT=0360h-0377h
 INIT=JUMPER(2) LOC(3-1) 000
 DMA=3
 TIMING=DEFAULT
 INIT=JUMPER(4) LOC(4-1) 1000
 INIT=JUMPER(5) LOC(4-1) 1000
 INIT=SOFTWARE(1) "360, IRQ9, DMA3"

CHOICE="Remote Reset Optn 0:  300,IRQ3,DMA5,C800"
 LINK
 IRQ=3
 INIT=JUMPER(1) LOC(4-1) 0010
 PORT=0300h-0317h
 DMA=5
 TIMING=DEFAULT
 INIT=JUMPER(4) LOC(4-1) 0100
 INIT=JUMPER(5) LOC(4-1) 0100
 LINK
 MEMORY=16K
 ADDRESS=0C8000h
 MEMTYPE=OTHER
 INIT=JUMPER(2) LOC(3-1) 111
 INIT=SOFTWARE(1) "300,IRQ3,DMA5,C800"

CHOICE="Remote Reset Optn 1:  320,IRQ4,DMA6,CC00"
 LINK
 IRQ=4
 INIT=JUMPER(1) LOC(4-1) 0100
 PORT=0320h-0337h
 DMA=6
 TIMING=DEFAULT
 INIT=JUMPER(4) LOC(4-1) 0010
 INIT=JUMPER(5) LOC(4-1) 0010
 LINK
 MEMORY=16K
 ADDRESS=0CC000h
 MEMTYPE=OTHER
 INIT=JUMPER(2) LOC(3-1) 110
 INIT=SOFTWARE(1) "320,IRQ4,DMA6,CC00"

CHOICE="Remote Reset Optn 2:  340,IRQ5,DMA7,D000"
 LINK
 IRQ=5
 INIT=JUMPER(1) LOC(4-1) 1000
 PORT=0340h-0357h
 DMA=7
 TIMING=DEFAULT
 INIT=JUMPER(4) LOC(4-1) 0001
 INIT=JUMPER(5) LOC(4-1) 0001
 LINK
 MEMORY=16K
 ADDRESS=0D0000h
 MEMTYPE=OTHER
 INIT=JUMPER(2) LOC(3-1) 101
 INIT=SOFTWARE(1) "340,IRQ5,DMA7,D000"

CHOICE="Remote Reset Optn 3:  360,IRQ9,DMA3,D400"
 LINK
 IRQ=9
 INIT=JUMPER(1) LOC(4-1) 0001
 PORT=0360h-0377h
 DMA=3
 TIMING=DEFAULT
 INIT=JUMPER(4) LOC(4-1) 1000
 INIT=JUMPER(5) LOC(4-1) 1000
 LINK
 MEMORY=16K
 ADDRESS=0D4000h
 MEMTYPE=OTHER
 INIT=JUMPER(2) LOC(3-1) 100
 INIT=SOFTWARE(1) "360,IRQ9,DMA3,D400"

CHOICE="Not Selected"

SUBFUNCTION="Connector Type"
 TYPE="NET"
 CONNECTION="Cheapernet uses BNC, Ethernet uses 15 pin DIX"
CHOICE="Cheapernet (BNC) Connection"
 AMPERAGE=1961
 FREE
 INIT=JUMPER(3) LOC(8-1) 00000000
 INIT=SOFTWARE(2) "Cheapernet"
CHOICE="Ethernet (DIX) Connection"
 FREE
 INIT=JUMPER(3) LOC(8-1) 11111111
 INIT=SOFTWARE(2) "Ethernet"

SUBFUNCTION="Added Wait State Option"
 TYPE="NET"
CHOICE="No Added Wait State"
 FREE
 INIT=JUMPER(6) LOC(1) 0
 INIT=SOFTWARE(3) "No Added Wait State"
CHOICE="One Added Wait State"
 FREE
 INIT=JUMPER(6) LOC(1) 1
 INIT=SOFTWARE(3) "One Added Wait State"


SUBFUNCTION="NE2100 IRQ Options"
 TYPE="NET"
  CHOICE="Not Selected"

CHOICE="IRQ 3"
 FREE
 IRQ=3
 INIT=JUMPER(1) LOC(4-1) 0010
 INIT=SOFTWARE(4) "IRQ 3"
CHOICE="IRQ 4"
 FREE
 IRQ=4
 INIT=JUMPER(1) LOC(4-1) 0100
 INIT=SOFTWARE(4) "IRQ 4"
CHOICE="IRQ 5"
 FREE
 IRQ=5
 INIT=JUMPER(1) LOC(4-1) 1000
 INIT=SOFTWARE(4) "IRQ 5"
CHOICE="IRQ 9"
 FREE
 IRQ=9
 INIT=JUMPER(1) LOC(4-1) 0001
 INIT=SOFTWARE(4) "IRQ 9"

SUBFUNCTION="NE2100 DMA Options"
 TYPE="NET"
CHOICE="Not Selected"
CHOICE="DMA 5"
 FREE
 DMA=5
 SIZE=WORD
 TIMING=DEFAULT
 INIT=JUMPER(4) LOC(4-1) 0100
 INIT=JUMPER(5) LOC(4-1) 0100
 INIT=SOFTWARE(5) "DMA 5"
CHOICE="DMA 6"
 FREE
 DMA=6
 SIZE=WORD
 TIMING=DEFAULT
 INIT=JUMPER(4) LOC(4-1) 0010
 INIT=JUMPER(5) LOC(4-1) 0010
 INIT=SOFTWARE(5) "DMA 6"
CHOICE="DMA 7"
 FREE
 DMA=7
 SIZE=WORD
 TIMING=DEFAULT
 INIT=JUMPER(4) LOC(4-1) 0001
 INIT=JUMPER(5) LOC(4-1) 0001
 INIT=SOFTWARE(5) "DMA 7"
CHOICE="DMA 3"
 FREE
 DMA=3
 SIZE=WORD
 TIMING=DEFAULT
 INIT=JUMPER(4) LOC(4-1) 1000
 INIT=JUMPER(5) LOC(4-1) 1000
 INIT=SOFTWARE(5) "DMA 3"


SUBFUNCTION="NE2100 I/O & Memory Options"
 TYPE="NET"
CHOICE="Not Selected"
CHOICE="I/O 300h & No EPROM"
 FREE
 PORT=0300h-0317h
 INIT=JUMPER(2) LOC(3-1) 011
 INIT=SOFTWARE(6) "I/O 300h & No EPROM"
CHOICE="I/O 320h & No EPROM"
 FREE
 PORT=0320h-0337h
 INIT=JUMPER(2) LOC(3-1) 010
 INIT=SOFTWARE(6) "I/O 320h & No EPROM"
CHOICE="I/O 340h & No EPROM"
 FREE
 PORT=0340h-0357h
 INIT=JUMPER(2) LOC(3-1) 001
 INIT=SOFTWARE(6) "I/O 340h & No EPROM"
CHOICE="I/O 360h & No EPROM"
 FREE
 PORT=0360h-0377h
 INIT=JUMPER(2) LOC(3-1) 000
 INIT=SOFTWARE(6) "I/O 360h & No EPROM"
CHOICE="I/O 300h & C800h"
 FREE
 PORT=0300h-0317h
 INIT=JUMPER(2) LOC(3-1) 011
 MEMORY=16K
 ADDRESS=0C8000h
 MEMTYPE=OTHER
 INIT=JUMPER(2) LOC(3-1) 111
 INIT=SOFTWARE(6) "I/O 300h & C800h"
CHOICE="I/O 320h & CC00h"
 AMPERAGE = 22
 FREE
 PORT=0320h-0337h
 INIT=JUMPER(2) LOC(3-1) 110
 MEMORY=16K
 ADDRESS=0CC000h
 MEMTYPE=OTHER
 INIT=JUMPER(2) LOC(3-1) 110
 INIT=SOFTWARE(6) "I/O 320h & CC00h"
CHOICE="I/O 340h & D000h"
 AMPERAGE = 22
 FREE
 PORT=0340h-0357h
 INIT=JUMPER(2) LOC(3-1) 101
 MEMORY=16K
 ADDRESS=0D0000h
 MEMTYPE=OTHER
 INIT=JUMPER(2) LOC(3-1) 101
 INIT=SOFTWARE(6) "I/O 340h & D000h"
CHOICE="I/O 360h & D400h"
 AMPERAGE = 22
 FREE
 PORT=0360h-0377h
 INIT=JUMPER(2) LOC(3-1) 100
 MEMORY=16K
 ADDRESS=0D4000h
 MEMTYPE=OTHER
 INIT=JUMPER(2) LOC(3-1) 100
 INIT=SOFTWARE(6) "I/O 360h & D400h"

SUBFUNCTION="NE2100 Automatic Configuration"
CHOICE="Not Selected"
CHOICE="Available Adapter Options"
 LINK
 IRQ=3|4|5|9
 INIT=JUMPER(1) LOC(4-1) 0010|0100|1000|0001
 INIT=SOFTWARE(7) "IRQ 3"|"IRQ 4"|"IRQ 5"|"IRQ 9"
 LINK
 PORT=0300h-0317h|0320h-0337h|0340h-0357h|0360h-0377h
 INIT=JUMPER(2) LOC(3-1) 011|010|001|000
 INIT=SOFTWARE(7) "IO 300"|"IO 320"|"IO 340"|"IO 360"
 LINK
 DMA=5|6|7|3
 SIZE=WORD
 TIMING=DEFAULT
 INIT=JUMPER(4)	LOC(4-1) 0100|0010|0001|1000
 INIT=JUMPER(5)	LOC(4-1) 0100|0010|0001|1000
 INIT=SOFTWARE(7) "DMA 5"|"DMA 6"|"DMA 7"|"DMA 3"