============================================================================================================================================== OFFSET 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F ---------------------------------------------------------------------------------------------------------------------------------------------- 00000000 4E 6F 76 65 6C 6C 20 48 65 6C 70 20 4C 69 62 72 61 72 69 61 6E 20 44 61 74 61 20 46 69 6C 65 20 Novell Help Librarian Data File 00000020 56 65 72 73 69 6F 6E 20 31 2E 30 30 0D 0A 43 4F 50 59 52 49 47 48 54 20 28 63 29 20 31 39 38 35 Version 1.00♪◙COPYRIGHT (c) 1985 00000040 20 62 79 20 4E 6F 76 65 6C 6C 2C 20 49 6E 63 2E 20 20 41 6C 6C 20 52 69 67 68 74 73 20 52 65 73 by Novell, Inc. All Rights Res 00000060 65 72 76 65 64 2E 0D 0A 1A 01 23 FA 04 01 00 1A 00 6A 00 00 00 F6 01 00 00 C0 04 00 00 DE 06 00 erved.♪◙→☺#·♦☺.→.j...÷☺..└♦..▐♠. 00000080 00 C1 08 00 00 77 0A 00 00 31 0E 00 00 AB 10 00 00 4D 12 00 00 E5 13 00 00 1E 16 00 00 02 18 00 .┴◘..w◙..1♫..½►..M↕..σ‼..▲▬..☻↑. 000000A0 00 48 1A 00 00 FF 1B 00 00 0B 1F 00 00 8E 20 00 00 70 23 00 00 2A 25 00 00 04 27 00 00 90 29 00 .H→.. ←..♂▼..Ä ..p#..*%..♦'..É). 000000C0 00 6C 2C 00 00 3F 2F 00 00 D1 30 00 00 AA 32 00 00 C1 36 00 00 5B 38 00 00 00 00 00 00 00 00 00 .l,..?/..╤0..¬2..┴6..[8......... 000000E0 00 07 10 0E 2F 0C 2D 00 02 02 01 00 02 00 00 74 01 20 20 20 20 20 45 44 49 54 20 42 52 49 44 47 .•►♫/♀-.☻☻☺.☻..t☺ EDIT BRIDG 00000100 45 20 52 45 4D 4F 54 45 20 53 45 52 56 45 52 20 4E 41 4D 45 20 48 45 4C 50 0A 0A 54 68 65 20 22 E REMOTE SERVER NAME HELP◙◙The " 00000120 52 65 6D 6F 74 65 20 53 65 72 76 65 72 20 4E 61 6D 65 22 20 6F 70 74 69 6F 6E 20 61 6C 6C 6F 77 Remote Server Name" option allow 00000140 73 20 79 6F 75 20 74 6F 20 73 70 65 63 69 66 79 20 74 68 65 20 6E 61 6D 65 20 6F 66 20 74 68 65 s you to specify the name of the 00000160 20 72 65 6D 6F 74 65 20 62 72 69 64 67 65 20 66 6F 72 20 74 68 65 20 73 65 6C 65 63 74 65 64 20 remote bridge for the selected 00000180 64 72 69 76 65 72 2E 20 20 53 70 61 63 65 73 20 61 72 65 20 6E 6F 74 20 61 6C 6C 6F 77 65 64 20 driver. Spaces are not allowed 000001A0 69 6E 20 74 68 65 20 72 65 6D 6F 74 65 20 62 72 69 64 67 65 20 6E 61 6D 65 2C 20 62 75 74 20 74 in the remote bridge name, but t 000001C0 68 65 20 75 6E 64 65 72 6C 69 6E 65 20 63 68 61 72 61 63 74 65 72 20 6D 61 79 20 62 65 20 75 73 he underline character may be us 000001E0 65 64 20 69 6E 73 74 65 61 64 2E 0A 0A 54 6F 20 73 70 65 63 69 66 79 20 74 68 65 20 72 65 6D 6F ed instead.◙◙To specify the remo 00000200 74 65 20 62 72 69 64 67 65 20 6E 61 6D 65 2C 20 74 79 70 65 20 74 68 65 20 6E 61 6D 65 20 61 6E te bridge name, type the name an 00000220 64 20 70 72 65 73 73 20 74 68 65 20 53 45 4C 45 43 54 20 6B 65 79 2E 0A 0A 20 20 20 20 20 20 20 d press the SELECT key.◙◙ 00000240 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 50 61 67 65 20 31 Page 1 00000260 20 6F 66 20 31 00 00 00 00 00 00 00 00 04 06 13 43 11 41 00 02 02 01 00 02 00 00 B2 02 20 20 20 of 1........♦♠‼C◄A.☻☻☺.☻..▓☻ 00000280 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 45 44 49 54 20 42 52 49 44 47 45 20 49 44 20 53 EDIT BRIDGE ID S 000002A0 54 52 49 4E 47 20 48 45 4C 50 0A 0A 54 68 65 20 22 49 44 20 53 74 72 69 6E 67 22 20 69 73 20 61 TRING HELP◙◙The "ID String" is a 000002C0 6E 20 6F 70 74 69 6F 6E 61 6C 20 62 75 74 20 72 65 63 6F 6D 6D 65 6E 64 65 64 20 73 65 63 75 72 n optional but recommended secur 000002E0 69 74 79 20 66 65 61 74 75 72 65 20 74 68 61 74 20 68 65 6C 70 73 20 63 6F 6E 74 72 6F 6C 20 61 ity feature that helps control a 00000300 63 63 65 73 73 20 74 6F 20 74 68 65 20 6E 65 74 77 6F 72 6B 2E 20 20 54 68 65 20 72 65 6D 6F 74 ccess to the network. The remot 00000320 65 20 77 6F 72 6B 73 74 61 74 69 6F 6E 20 73 68 65 6C 6C 20 6F 72 20 72 65 6D 6F 74 65 20 62 72 e workstation shell or remote br 00000340 69 64 67 65 20 79 6F 75 20 63 72 65 61 74 65 20 6C 61 74 65 72 20 6D 75 73 74 20 75 73 65 20 74 idge you create later must use t 00000360 68 65 20 65 78 61 63 74 20 49 44 20 73 74 72 69 6E 67 20 79 6F 75 20 73 70 65 63 69 66 79 20 68 he exact ID string you specify h 00000380 65 72 65 20 69 6E 20 74 68 65 20 62 72 69 64 67 65 20 73 6F 66 74 77 61 72 65 3B 20 6F 74 68 65 ere in the bridge software; othe 000003A0 72 77 69 73 65 2C 20 74 68 65 20 72 65 6D 6F 74 65 20 6C 6F 63 61 74 69 6F 6E 20 77 69 6C 6C 20 rwise, the remote location will 000003C0 6E 6F 74 20 62 65 20 61 62 6C 65 20 74 6F 20 65 73 74 61 62 6C 69 73 68 20 61 20 63 6F 6E 6E 65 not be able to establish a conne 000003E0 63 74 69 6F 6E 20 77 69 74 68 20 74 68 65 20 62 72 69 64 67 65 2E 0A 0A 59 6F 75 20 6D 75 73 74 ction with the bridge.◙◙You must 00000400 20 75 73 65 20 74 68 65 20 73 61 6D 65 20 6C 65 74 74 65 72 20 63 61 73 65 20 77 68 65 6E 20 73 use the same letter case when s 00000420 70 65 63 69 66 79 69 6E 67 20 74 68 65 20 49 44 20 73 74 72 69 6E 67 20 69 6E 20 74 68 65 20 62 pecifying the ID string in the b 00000440 72 69 64 67 65 20 73 6F 66 74 77 61 72 65 20 61 6E 64 20 69 6E 20 74 68 65 20 72 65 6D 6F 74 65 ridge software and in the remote 00000460 20 77 6F 72 6B 73 74 61 74 69 6F 6E 20 73 68 65 6C 6C 2E 20 20 22 41 42 43 22 20 61 6E 64 20 22 workstation shell. "ABC" and " 00000480 61 62 63 22 20 61 72 65 20 4E 4F 54 20 54 48 45 20 53 41 4D 45 21 0A 20 0A 54 6F 20 73 70 65 63 abc" are NOT THE SAME!◙ ◙To spec 000004A0 69 66 79 20 74 68 65 20 49 44 20 73 74 72 69 6E 67 2C 20 65 6E 74 65 72 20 61 73 20 6D 61 6E 79 ify the ID string, enter as many 000004C0 20 61 73 20 6E 69 6E 65 20 63 68 61 72 61 63 74 65 72 73 20 61 6E 64 20 70 72 65 73 73 20 74 68 as nine characters and press th 000004E0 65 20 53 45 4C 45 43 54 20 6B 65 79 2E 0A 0A 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 e SELECT key.◙◙ 00000500 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 00000520 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 00 00 00 00 00 00 00 00 05 09 11 3D 0F 3B 00 02 02 Page 1 of 1........♣○◄=☼;.☻☻ 00000540 01 00 02 00 00 06 02 20 20 20 20 20 20 20 20 20 20 20 20 20 20 45 44 49 54 20 42 52 49 44 47 45 ☺.☻..♠☻ EDIT BRIDGE 00000560 20 43 4F 4E 54 52 4F 4C 20 50 41 53 53 57 4F 52 44 20 48 45 4C 50 0A 0A 54 68 65 20 22 43 6F 6E CONTROL PASSWORD HELP◙◙The "Con 00000580 74 72 6F 6C 20 50 61 73 73 77 6F 72 64 22 20 69 73 20 61 6E 20 6F 70 74 69 6F 6E 61 6C 20 62 75 trol Password" is an optional bu 000005A0 74 20 72 65 63 6F 6D 6D 65 6E 64 65 64 20 73 65 63 75 72 69 74 79 20 66 65 61 74 75 72 65 20 74 t recommended security feature t 000005C0 68 61 74 20 68 65 6C 70 73 20 63 6F 6E 74 72 6F 6C 20 61 63 63 65 73 73 20 74 6F 20 74 68 65 20 hat helps control access to the 000005E0 6E 65 74 77 6F 72 6B 2E 20 20 54 68 65 20 63 6F 6E 74 72 6F 6C 20 70 61 73 73 77 6F 72 64 20 69 network. The control password i 00000600 73 20 75 73 65 64 20 69 6E 20 72 75 6E 6E 69 6E 67 20 74 68 65 20 4C 43 4F 4E 53 4F 4C 45 20 75 s used in running the LCONSOLE u 00000620 74 69 6C 69 74 79 2E 0A 0A 54 68 65 20 6C 65 74 74 65 72 20 63 61 73 65 20 73 70 65 63 69 66 69 tility.◙◙The letter case specifi 00000640 65 64 20 66 6F 72 20 74 68 65 20 63 6F 6E 74 72 6F 6C 20 70 61 73 73 77 6F 72 64 20 64 75 72 69 ed for the control password duri 00000660 6E 67 20 62 72 69 64 67 65 20 63 6F 6E 66 69 67 75 72 61 74 69 6F 6E 20 6D 75 73 74 20 61 67 72 ng bridge configuration must agr 00000680 65 65 20 77 69 74 68 20 74 68 61 74 20 75 73 65 64 20 74 6F 20 72 75 6E 20 4C 43 4F 4E 53 4F 4C ee with that used to run LCONSOL 000006A0 45 2E 20 20 22 41 42 43 22 20 61 6E 64 20 22 61 62 63 22 20 61 72 65 20 4E 4F 54 20 54 48 45 20 E. "ABC" and "abc" are NOT THE 000006C0 53 41 4D 45 21 0A 0A 54 6F 20 73 70 65 63 69 66 79 20 61 20 63 6F 6E 74 72 6F 6C 20 70 61 73 73 SAME!◙◙To specify a control pass 000006E0 77 6F 72 64 2C 20 74 79 70 65 20 74 68 65 20 70 61 73 73 77 6F 72 64 20 61 6E 64 20 70 72 65 73 word, type the password and pres 00000700 73 20 74 68 65 20 53 45 4C 45 43 54 20 6B 65 79 2E 0A 0A 20 20 20 20 20 20 20 20 20 20 20 20 20 s the SELECT key.◙◙ 00000720 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 00000740 20 20 50 61 67 65 20 31 20 6F 66 20 31 00 00 00 00 00 00 00 00 06 0A 10 3C 0E 3A 00 02 02 01 00 Page 1 of 1........♠◙►<♫:.☻☻☺. 00000760 02 00 00 CB 01 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 45 44 49 54 20 42 52 ☻..╦☺ EDIT BR 00000780 49 44 47 45 20 48 45 4C 50 0A 0A 59 6F 75 20 6D 75 73 74 20 63 6F 6E 66 69 67 75 72 65 20 74 68 IDGE HELP◙◙You must configure th 000007A0 65 20 62 72 69 64 67 65 20 66 6F 72 20 65 61 63 68 20 72 65 6D 6F 74 65 20 64 72 69 76 65 72 20 e bridge for each remote driver 000007C0 79 6F 75 20 73 65 6C 65 63 74 65 64 20 64 75 72 69 6E 67 20 74 68 65 20 62 72 69 64 67 65 20 67 you selected during the bridge g 000007E0 65 6E 65 72 61 74 69 6F 6E 20 70 72 6F 63 65 73 73 2E 20 20 54 68 65 20 66 69 72 73 74 20 74 77 eneration process. The first tw 00000800 6F 20 69 74 65 6D 73 20 69 6E 20 74 68 65 20 22 45 64 69 74 20 42 72 69 64 67 65 22 20 77 69 6E o items in the "Edit Bridge" win 00000820 64 6F 77 2C 20 22 4E 75 6D 62 65 72 20 6F 66 20 6C 69 6E 65 73 22 20 61 6E 64 20 22 4C 41 4E 20 dow, "Number of lines" and "LAN 00000840 44 72 69 76 65 72 2C 22 20 68 61 76 65 20 61 6C 72 65 61 64 79 20 62 65 65 6E 20 73 65 6C 65 63 Driver," have already been selec 00000860 74 65 64 20 61 6E 64 20 63 61 6E 6E 6F 74 20 62 65 20 65 64 69 74 65 64 2E 20 20 54 68 65 20 66 ted and cannot be edited. The f 00000880 6F 6C 6C 6F 77 69 6E 67 20 69 74 65 6D 73 20 6D 61 79 20 62 65 20 63 6F 6E 66 69 67 75 72 65 64 ollowing items may be configured 000008A0 20 66 72 6F 6D 20 74 68 65 20 22 45 64 69 74 20 42 72 69 64 67 65 22 20 77 69 6E 64 6F 77 3A 0A from the "Edit Bridge" window:◙ 000008C0 0A 20 20 52 65 6D 6F 74 65 20 53 65 72 76 65 72 20 4E 61 6D 65 0A 20 20 49 44 20 53 74 72 69 6E ◙ Remote Server Name◙ ID Strin 000008E0 67 0A 20 20 43 6F 6E 74 72 6F 6C 20 50 61 73 73 77 6F 72 64 0A 0A 20 20 20 20 20 20 20 20 20 20 g◙ Control Password◙◙ 00000900 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 00000920 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 0A 00 00 00 00 00 00 00 00 06 0B 10 39 0E 37 00 02 Page 1 of 1◙........♠♂►9♫7.☻ 00000940 02 01 00 02 00 00 9E 01 20 20 20 20 20 20 20 20 20 20 20 20 20 20 45 44 49 54 20 42 52 49 44 47 ☻☺.☻..₧☺ EDIT BRIDG 00000960 45 20 53 41 56 45 20 43 48 41 4E 47 45 53 20 48 45 4C 50 0A 0A 54 68 65 20 22 53 61 76 65 20 43 E SAVE CHANGES HELP◙◙The "Save C 00000980 68 61 6E 67 65 73 22 20 63 6F 6E 66 69 72 6D 61 74 69 6F 6E 20 62 6F 78 20 61 6C 6C 6F 77 73 20 hanges" confirmation box allows 000009A0 79 6F 75 20 74 6F 20 73 61 76 65 20 74 68 65 20 62 72 69 64 67 65 20 63 6F 6E 66 69 67 75 72 61 you to save the bridge configura 000009C0 74 69 6F 6E 73 20 79 6F 75 20 6A 75 73 74 20 73 65 6C 65 63 74 65 64 2E 0A 0A 54 6F 20 73 61 76 tions you just selected.◙◙To sav 000009E0 65 20 74 68 65 20 73 65 6C 65 63 74 65 64 20 62 72 69 64 67 65 20 63 6F 6E 66 69 67 75 72 61 74 e the selected bridge configurat 00000A00 69 6F 6E 73 2C 20 68 69 67 68 6C 69 67 68 74 20 22 59 65 73 22 20 61 6E 64 20 70 72 65 73 73 20 ions, highlight "Yes" and press 00000A20 74 68 65 20 53 45 4C 45 43 54 20 6B 65 79 2E 0A 0A 54 6F 20 64 65 6C 65 74 65 20 74 68 65 20 73 the SELECT key.◙◙To delete the s 00000A40 65 6C 65 63 74 65 64 20 63 6F 6E 66 69 67 75 72 61 74 69 6F 6E 73 2C 20 68 69 67 68 6C 69 67 68 elected configurations, highligh 00000A60 74 20 22 4E 6F 22 20 61 6E 64 20 70 72 65 73 73 20 74 68 65 20 53 45 4C 45 43 54 20 6B 65 79 2E t "No" and press the SELECT key. 00000A80 0A 0A 54 68 65 20 22 4D 61 69 6E 20 4D 65 6E 75 22 20 77 69 6C 6C 20 72 65 61 70 70 65 61 72 20 ◙◙The "Main Menu" will reappear 00000AA0 6F 6E 20 74 68 65 20 73 63 72 65 65 6E 2E 0A 0A 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 on the screen.◙◙ 00000AC0 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 50 61 67 65 20 Page 00000AE0 31 20 6F 66 20 31 16 0C 00 00 00 00 00 00 07 0E 0E 34 0C 32 00 02 02 01 00 02 00 00 87 01 20 20 1 of 1▬♀......•♫♫4♀2.☻☻☺.☻..ç☺ 00000B00 20 20 20 20 20 20 20 20 20 20 20 45 44 49 54 20 4C 49 4E 45 20 42 41 55 44 20 52 41 54 45 20 48 EDIT LINE BAUD RATE H 00000B20 45 4C 50 0A 0A 54 68 65 20 22 42 61 75 64 20 52 61 74 65 22 20 6F 70 74 69 6F 6E 20 61 6C 6C 6F ELP◙◙The "Baud Rate" option allo 00000B40 77 73 20 79 6F 75 20 74 6F 20 73 65 6C 65 63 74 20 74 68 65 20 62 61 75 64 20 72 61 74 65 20 66 ws you to select the baud rate f 00000B60 6F 72 20 74 68 65 20 6D 6F 64 65 6D 20 61 74 20 74 68 65 20 62 72 69 64 67 65 20 65 6E 64 20 6F or the modem at the bridge end o 00000B80 66 20 74 68 65 20 73 65 6C 65 63 74 65 64 20 63 6F 6E 6E 65 63 74 69 6F 6E 2E 20 20 54 68 65 20 f the selected connection. The 00000BA0 72 65 63 6F 6D 6D 65 6E 64 65 64 20 62 61 75 64 20 72 61 74 65 73 20 66 6F 72 20 79 6F 75 72 20 recommended baud rates for your 00000BC0 6D 6F 64 65 6D 20 61 72 65 20 6C 69 73 74 65 64 20 69 6E 20 74 68 65 20 6D 61 6E 75 61 6C 20 74 modem are listed in the manual t 00000BE0 68 61 74 20 63 61 6D 65 20 77 69 74 68 20 69 74 2E 0A 0A 49 66 20 79 6F 75 20 61 72 65 20 75 73 hat came with it.◙◙If you are us 00000C00 69 6E 67 20 61 20 48 61 79 65 73 20 6F 72 20 63 6F 6D 70 61 74 69 62 6C 65 20 6D 6F 64 65 6D 2C ing a Hayes or compatible modem, 00000C20 20 73 65 74 20 69 74 73 20 62 61 75 64 20 72 61 74 65 20 74 6F 20 74 68 65 20 68 69 67 68 65 73 set its baud rate to the highes 00000C40 74 20 69 74 20 77 69 6C 6C 20 73 75 70 70 6F 72 74 2E 0A 0A 20 20 20 20 20 20 20 20 20 20 20 20 t it will support.◙◙ 00000C60 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 50 61 67 65 20 31 Page 1 00000C80 20 6F 66 20 32 00 00 00 00 77 0A 00 00 05 0C 11 37 0F 35 00 02 02 01 00 02 00 00 03 02 20 20 20 of 2....w◙..♣♀◄7☼5.☻☻☺.☻..♥☻ 00000CA0 20 20 20 20 20 20 20 20 20 20 20 20 45 44 49 54 20 4C 49 4E 45 20 42 41 55 44 20 52 41 54 45 20 EDIT LINE BAUD RATE 00000CC0 48 45 4C 50 0A 0A 49 66 20 79 6F 75 20 61 72 65 20 75 73 69 6E 67 20 61 20 6D 6F 64 65 6D 20 74 HELP◙◙If you are using a modem t 00000CE0 68 61 74 20 69 73 20 6E 6F 74 20 61 20 48 61 79 65 73 20 6F 72 20 63 6F 6D 70 61 74 69 62 6C 65 hat is not a Hayes or compatible 00000D00 2C 20 73 65 74 20 69 74 73 20 62 61 75 64 20 72 61 74 65 20 74 6F 20 74 68 65 20 68 69 67 68 65 , set its baud rate to the highe 00000D20 73 74 20 63 6F 6D 6D 6F 6E 20 64 65 6E 6F 6D 69 6E 61 74 6F 72 20 6F 66 20 61 6C 6C 20 74 68 65 st common denominator of all the 00000D40 20 6D 6F 64 65 6D 73 20 79 6F 75 20 61 72 65 20 75 73 69 6E 67 2E 0A 0A 49 66 20 79 6F 75 20 61 modems you are using.◙◙If you a 00000D60 72 65 20 75 73 69 6E 67 20 61 20 43 4F 4D 31 2F 43 4F 4D 32 20 62 6F 61 72 64 20 69 6E 20 61 20 re using a COM1/COM2 board in a 00000D80 6E 6F 6E 64 65 64 69 63 61 74 65 64 20 65 78 74 65 72 6E 61 6C 20 62 72 69 64 67 65 2C 20 79 6F nondedicated external bridge, yo 00000DA0 75 20 6D 75 73 74 20 75 73 65 20 61 20 62 61 75 64 20 72 61 74 65 20 6F 66 20 32 34 30 30 20 6F u must use a baud rate of 2400 o 00000DC0 72 20 6C 65 73 73 2E 20 20 49 66 20 79 6F 75 20 6E 65 65 64 20 61 20 62 61 75 64 20 72 61 74 65 r less. If you need a baud rate 00000DE0 20 67 72 65 61 74 65 72 20 74 68 61 6E 20 32 34 30 30 2C 20 79 6F 75 20 6D 75 73 74 20 75 73 65 greater than 2400, you must use 00000E00 20 61 20 64 65 64 69 63 61 74 65 64 20 62 72 69 64 67 65 2E 0A 0A 54 6F 20 73 70 65 63 69 66 79 a dedicated bridge.◙◙To specify 00000E20 20 74 68 65 20 62 61 75 64 20 72 61 74 65 2C 20 68 69 67 68 6C 69 67 68 74 20 74 68 65 20 61 70 the baud rate, highlight the ap 00000E40 70 72 6F 70 72 69 61 74 65 20 6F 70 74 69 6F 6E 20 61 6E 64 20 70 72 65 73 73 20 74 68 65 20 53 propriate option and press the S 00000E60 45 4C 45 43 54 20 6B 65 79 2E 0A 0A 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 ELECT key.◙◙ 00000E80 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 50 61 67 65 20 32 20 6F 66 20 32 Page 2 of 2 00000EA0 00 00 00 00 00 00 00 00 04 08 14 3F 12 3D 00 02 02 01 00 02 00 00 62 02 20 20 20 20 20 20 20 20 ........♦◘¶?↕=.☻☻☺.☻..b☻ 00000EC0 20 20 20 20 20 20 20 20 20 20 45 44 49 54 20 4C 49 4E 45 20 4D 4F 44 45 4D 20 54 59 50 45 20 48 EDIT LINE MODEM TYPE H 00000EE0 45 4C 50 0A 0A 54 68 65 20 22 4D 6F 64 65 6D 20 54 79 70 65 22 20 6F 70 74 69 6F 6E 20 61 6C 6C ELP◙◙The "Modem Type" option all 00000F00 6F 77 73 20 79 6F 75 20 74 6F 20 73 70 65 63 69 66 79 20 77 68 65 74 68 65 72 20 74 68 65 20 73 ows you to specify whether the s 00000F20 65 6C 65 63 74 65 64 20 6C 69 6E 65 27 73 20 6D 6F 64 65 6D 20 69 73 20 61 20 22 48 61 79 65 73 elected line's modem is a "Hayes 00000F40 20 43 6F 6D 70 61 74 69 62 6C 65 22 20 6F 72 20 61 20 22 53 70 65 63 69 61 6C 20 43 6F 6E 66 69 Compatible" or a "Special Confi 00000F60 67 75 72 61 74 69 6F 6E 2E 22 0A 0A 49 66 20 79 6F 75 72 20 6D 6F 64 65 6D 20 69 73 20 6E 6F 74 guration."◙◙If your modem is not 00000F80 20 61 20 48 61 79 65 73 20 6F 72 20 63 6F 6D 70 61 74 69 62 6C 65 2C 20 79 6F 75 20 6D 75 73 74 a Hayes or compatible, you must 00000FA0 20 73 65 6C 65 63 74 20 74 68 65 20 22 53 70 65 63 69 61 6C 20 43 6F 6E 66 69 67 75 72 61 74 69 select the "Special Configurati 00000FC0 6F 6E 22 20 6F 70 74 69 6F 6E 2E 0A 0A 54 68 65 20 22 53 70 65 63 69 61 6C 20 43 6F 6E 66 69 67 on" option.◙◙The "Special Config 00000FE0 75 72 61 74 69 6F 6E 22 20 6F 70 74 69 6F 6E 20 61 6C 6C 6F 77 73 20 79 6F 75 20 74 6F 20 75 73 uration" option allows you to us 00001000 65 20 61 6C 6D 6F 73 74 20 61 6E 79 20 6D 6F 64 65 6D 3B 20 68 6F 77 65 76 65 72 2C 20 74 68 65 e almost any modem; however, the 00001020 20 62 72 69 64 67 65 20 63 6F 6E 66 69 67 75 72 61 74 69 6F 6E 20 70 72 6F 63 65 73 73 20 77 69 bridge configuration process wi 00001040 6C 6C 20 61 6C 6C 6F 77 20 79 6F 75 20 74 6F 20 73 70 65 63 69 66 79 20 6F 6E 6C 79 20 74 68 65 ll allow you to specify only the 00001060 20 62 61 75 64 20 72 61 74 65 20 69 66 20 74 68 69 73 20 6F 70 74 69 6F 6E 20 69 73 20 73 65 6C baud rate if this option is sel 00001080 65 63 74 65 64 2E 0A 0A 54 6F 20 73 65 6C 65 63 74 20 74 68 65 20 6D 6F 64 65 6D 20 74 79 70 65 ected.◙◙To select the modem type 000010A0 2C 20 68 69 67 68 6C 69 67 68 74 20 74 68 65 20 61 70 70 72 6F 70 72 69 61 74 65 20 6F 70 74 69 , highlight the appropriate opti 000010C0 6F 6E 20 61 6E 64 20 70 72 65 73 73 20 74 68 65 20 53 45 4C 45 43 54 20 6B 65 79 2E 0A 0A 20 20 on and press the SELECT key.◙◙ 000010E0 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 00001100 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 00 00 00 00 00 00 Page 1 of 1...... 00001120 00 00 06 0C 0F 37 0D 35 00 02 02 01 00 02 00 00 8A 01 20 20 20 20 20 20 20 20 20 20 20 20 20 20 ..♠♀☼7♪5.☻☻☺.☻..è☺ 00001140 45 44 49 54 20 4C 49 4E 45 20 44 49 41 4C 20 4D 4F 44 45 20 48 45 4C 50 0A 0A 54 68 65 20 22 44 EDIT LINE DIAL MODE HELP◙◙The "D 00001160 69 61 6C 20 4D 6F 64 65 22 20 6F 70 74 69 6F 6E 20 61 6C 6C 6F 77 73 20 79 6F 75 20 74 6F 20 73 ial Mode" option allows you to s 00001180 70 65 63 69 66 79 20 77 68 65 74 68 65 72 20 74 68 65 20 6D 6F 64 65 6D 20 77 69 6C 6C 20 6D 61 pecify whether the modem will ma 000011A0 6B 65 20 74 68 65 20 73 65 6C 65 63 74 65 64 20 63 6F 6E 6E 65 63 74 69 6F 6E 20 62 79 20 75 73 ke the selected connection by us 000011C0 69 6E 67 20 61 20 74 6F 75 63 68 20 74 6F 6E 65 20 6F 72 20 70 75 6C 73 65 20 64 69 61 6C 20 6D ing a touch tone or pulse dial m 000011E0 6F 64 65 2E 0A 0A 49 66 20 79 6F 75 20 68 61 76 65 20 61 20 48 61 79 65 73 20 6F 72 20 63 6F 6D ode.◙◙If you have a Hayes or com 00001200 70 61 74 69 62 6C 65 20 6D 6F 64 65 6D 2C 20 79 6F 75 20 6D 75 73 74 20 73 65 6C 65 63 74 20 74 patible modem, you must select t 00001220 68 65 20 22 44 69 61 6C 20 4D 6F 64 65 2E 22 0A 0A 54 6F 20 73 70 65 63 69 66 79 20 74 68 65 20 he "Dial Mode."◙◙To specify the 00001240 70 68 6F 6E 65 20 74 79 70 65 2C 20 68 69 67 68 6C 69 67 68 74 20 74 68 65 20 61 70 70 72 6F 70 phone type, highlight the approp 00001260 72 69 61 74 65 20 6F 70 74 69 6F 6E 20 61 6E 64 20 70 72 65 73 73 20 74 68 65 20 53 45 4C 45 43 riate option and press the SELEC 00001280 54 20 6B 65 79 2E 0A 0A 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 T key.◙◙ 000012A0 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 00 00 00 00 Page 1 of 1.... 000012C0 00 00 00 00 06 0A 0F 3B 0D 39 00 02 02 01 00 02 00 00 80 01 20 20 20 20 20 20 20 20 20 20 20 20 ....♠◙☼;♪9.☻☻☺.☻..Ç☺ 000012E0 20 20 20 45 44 49 54 20 4C 49 4E 45 20 41 55 54 4F 20 43 4F 4E 4E 45 43 54 20 48 45 4C 50 0A 0A EDIT LINE AUTO CONNECT HELP◙◙ 00001300 54 68 65 20 22 41 75 74 6F 20 43 6F 6E 6E 65 63 74 22 20 6F 70 74 69 6F 6E 20 61 6C 6C 6F 77 73 The "Auto Connect" option allows 00001320 20 79 6F 75 20 74 6F 20 69 6E 73 74 72 75 63 74 20 74 68 65 20 62 72 69 64 67 65 20 74 6F 20 61 you to instruct the bridge to a 00001340 75 74 6F 6D 61 74 69 63 61 6C 6C 79 20 65 73 74 61 62 6C 69 73 68 20 61 20 63 6F 6E 6E 65 63 74 utomatically establish a connect 00001360 69 6F 6E 20 77 69 74 68 20 74 68 65 20 72 65 6D 6F 74 65 20 74 61 72 67 65 74 2E 20 20 0A 0A 54 ion with the remote target. ◙◙T 00001380 6F 20 65 73 74 61 62 6C 69 73 68 20 61 6E 20 61 75 74 6F 6D 61 74 69 63 20 63 6F 6E 6E 65 63 74 o establish an automatic connect 000013A0 69 6F 6E 2C 20 70 72 65 73 73 20 22 59 22 20 61 6E 64 20 74 68 65 20 53 45 4C 45 43 54 20 6B 65 ion, press "Y" and the SELECT ke 000013C0 79 2E 0A 0A 49 66 20 79 6F 75 20 64 6F 20 6E 6F 74 20 77 69 73 68 20 74 6F 20 65 73 74 61 62 6C y.◙◙If you do not wish to establ 000013E0 69 73 68 20 61 6E 20 61 75 74 6F 6D 61 74 69 63 20 63 6F 6E 6E 65 63 74 69 6F 6E 2C 20 70 72 65 ish an automatic connection, pre 00001400 73 73 20 22 4E 22 20 61 6E 64 20 74 68 65 20 53 45 4C 45 43 54 20 6B 65 79 2E 0A 0A 20 20 20 20 ss "N" and the SELECT key.◙◙ 00001420 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 00001440 20 20 20 20 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 00 00 00 00 00 00 00 00 04 08 13 40 Page 1 of 1........♦◘‼@ 00001460 11 3E 00 02 02 01 00 02 00 00 21 02 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 45 44 ◄>.☻☻☺.☻..!☻ ED 00001480 49 54 20 4C 49 4E 45 20 50 48 4F 4E 45 20 4E 55 4D 42 45 52 20 48 45 4C 50 0A 0A 54 68 65 20 22 IT LINE PHONE NUMBER HELP◙◙The " 000014A0 50 68 6F 6E 65 20 4E 75 6D 62 65 72 22 20 6F 70 74 69 6F 6E 20 61 6C 6C 6F 77 73 20 79 6F 75 20 Phone Number" option allows you 000014C0 74 6F 20 73 70 65 63 69 66 79 20 74 68 65 20 70 68 6F 6E 65 20 6E 75 6D 62 65 72 20 6F 66 20 74 to specify the phone number of t 000014E0 68 65 20 62 72 69 64 67 65 20 79 6F 75 20 61 72 65 20 64 69 61 6C 69 6E 67 2E 0A 0A 49 66 20 79 he bridge you are dialing.◙◙If y 00001500 6F 75 20 68 61 76 65 20 61 20 48 61 79 65 73 20 6F 72 20 63 6F 6D 70 61 74 69 62 6C 65 20 6D 6F ou have a Hayes or compatible mo 00001520 64 65 6D 20 61 6E 64 20 68 61 76 65 20 73 70 65 63 69 66 69 65 64 20 61 6E 20 61 75 74 6F 6D 61 dem and have specified an automa 00001540 74 69 63 20 63 6F 6E 6E 65 63 74 69 6F 6E 2C 20 79 6F 75 20 6D 75 73 74 20 65 6E 74 65 72 20 74 tic connection, you must enter t 00001560 68 65 20 70 68 6F 6E 65 20 6E 75 6D 62 65 72 20 6F 66 20 74 68 65 20 62 72 69 64 67 65 2E 0A 0A he phone number of the bridge.◙◙ 00001580 54 68 65 20 70 72 6F 6D 70 74 20 70 72 6F 76 69 64 65 73 20 61 20 70 6F 72 74 69 6F 6E 20 6F 66 The prompt provides a portion of 000015A0 20 74 68 65 20 63 6F 6D 6D 61 6E 64 20 73 74 72 69 6E 67 20 74 68 61 74 20 63 6F 72 72 65 73 70 the command string that corresp 000015C0 6F 6E 64 73 20 77 69 74 68 20 74 68 65 20 73 65 6C 65 63 74 65 64 20 62 61 75 64 20 72 61 74 65 onds with the selected baud rate 000015E0 2E 20 20 54 68 69 73 20 70 6F 72 74 69 6F 6E 20 63 61 6E 6E 6F 74 20 62 65 20 65 64 69 74 65 64 . This portion cannot be edited 00001600 2E 0A 0A 41 64 64 20 74 68 65 20 70 68 6F 6E 65 20 6E 75 6D 62 65 72 20 6F 66 20 74 68 65 20 62 .◙◙Add the phone number of the b 00001620 72 69 64 67 65 20 74 6F 20 74 68 69 73 20 73 74 72 69 6E 67 20 61 6E 64 20 70 72 65 73 73 20 74 ridge to this string and press t 00001640 68 65 20 53 45 4C 45 43 54 20 6B 65 79 2E 0A 0A 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 he SELECT key.◙◙ 00001660 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 00001680 20 20 50 61 67 65 20 31 20 6F 66 20 31 00 00 00 00 00 00 00 00 05 0C 11 37 0F 35 00 02 02 01 00 Page 1 of 1........♣♀◄7☼5.☻☻☺. 000016A0 02 00 00 CC 01 20 20 20 20 20 20 20 20 20 20 20 20 45 44 49 54 20 4C 49 4E 45 20 41 55 54 4F 20 ☻..╠☺ EDIT LINE AUTO 000016C0 49 44 20 53 54 52 49 4E 47 20 48 45 4C 50 0A 0A 54 68 65 20 22 41 75 74 6F 20 49 44 20 53 74 72 ID STRING HELP◙◙The "Auto ID Str 000016E0 69 6E 67 22 20 6F 70 74 69 6F 6E 20 61 6C 6C 6F 77 73 20 79 6F 75 20 74 6F 20 73 70 65 63 69 66 ing" option allows you to specif 00001700 79 20 74 68 65 20 49 44 20 73 74 72 69 6E 67 20 6F 66 20 74 68 65 20 62 72 69 64 67 65 20 79 6F y the ID string of the bridge yo 00001720 75 20 61 72 65 20 63 61 6C 6C 69 6E 67 2E 0A 0A 54 68 65 20 6C 65 74 74 65 72 20 63 61 73 65 20 u are calling.◙◙The letter case 00001740 6F 66 20 74 68 65 20 22 41 75 74 6F 20 49 44 20 53 74 72 69 6E 67 22 20 6D 75 73 74 20 6D 61 74 of the "Auto ID String" must mat 00001760 63 68 20 74 68 65 20 63 61 73 65 20 65 6E 74 65 72 65 64 20 77 68 65 6E 20 74 68 65 20 49 44 20 ch the case entered when the ID 00001780 73 74 72 69 6E 67 20 6F 66 20 74 68 65 20 72 65 6D 6F 74 65 20 62 72 69 64 67 65 20 77 61 73 20 string of the remote bridge was 000017A0 73 70 65 63 69 66 69 65 64 2E 20 20 22 41 42 43 22 20 61 6E 64 20 22 61 62 63 22 20 61 72 65 20 specified. "ABC" and "abc" are 000017C0 4E 4F 54 20 54 48 45 20 53 41 4D 45 21 0A 0A 54 6F 20 73 70 65 63 69 66 79 20 74 68 65 20 22 41 NOT THE SAME!◙◙To specify the "A 000017E0 75 74 6F 20 49 44 20 53 74 72 69 6E 67 2C 22 20 74 79 70 65 20 74 68 65 20 49 44 20 73 74 72 69 uto ID String," type the ID stri 00001800 6E 67 20 6F 66 20 74 68 65 20 62 72 69 64 67 65 20 79 6F 75 20 61 72 65 20 63 61 6C 6C 69 6E 67 ng of the bridge you are calling 00001820 20 61 6E 64 20 70 72 65 73 73 20 74 68 65 20 53 45 4C 45 43 54 20 6B 65 79 2E 0A 0A 20 20 20 20 and press the SELECT key.◙◙ 00001840 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 00001860 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 0A 00 00 00 00 00 00 00 00 04 0A 13 3C 11 3A 00 Page 1 of 1◙........♦◙‼<◄:. 00001880 02 02 01 00 02 00 00 2E 02 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 45 44 49 54 20 4C ☻☻☺.☻...☻ EDIT L 000018A0 49 4E 45 20 4C 49 46 45 20 43 4C 41 53 53 20 48 45 4C 50 0A 0A 54 68 65 20 22 4C 69 66 65 20 43 INE LIFE CLASS HELP◙◙The "Life C 000018C0 6C 61 73 73 22 20 6F 70 74 69 6F 6E 20 61 6C 6C 6F 77 73 20 79 6F 75 20 74 6F 20 69 6E 64 69 63 lass" option allows you to indic 000018E0 61 74 65 20 77 68 65 74 68 65 72 20 20 74 68 65 20 73 65 6C 65 63 74 65 64 20 6C 69 6E 65 20 63 ate whether the selected line c 00001900 6F 6E 6E 65 63 74 69 6F 6E 20 77 69 6C 6C 20 62 65 20 63 6F 6E 74 69 6E 75 6F 75 73 20 6F 72 20 onnection will be continuous or 00001920 74 69 6D 65 64 2E 0A 0A 49 66 20 74 68 65 20 63 6F 6E 6E 65 63 74 69 6F 6E 20 69 73 20 63 6F 6E timed.◙◙If the connection is con 00001940 74 69 6E 75 6F 75 73 2C 20 69 74 20 6D 75 73 74 20 62 65 20 74 65 72 6D 69 6E 61 74 65 64 20 6D tinuous, it must be terminated m 00001960 61 6E 75 61 6C 6C 79 2E 0A 0A 49 66 20 74 68 65 20 63 6F 6E 6E 65 63 74 69 6F 6E 20 69 73 20 74 anually.◙◙If the connection is t 00001980 69 6D 65 64 2C 20 69 74 20 77 69 6C 6C 20 62 65 20 74 65 72 6D 69 6E 61 74 65 64 20 61 75 74 6F imed, it will be terminated auto 000019A0 6D 61 74 69 63 61 6C 6C 79 20 77 68 65 6E 20 6E 6F 20 70 61 63 6B 65 74 20 61 63 74 69 76 69 74 matically when no packet activit 000019C0 79 20 68 61 73 20 6F 63 63 75 72 72 65 64 20 66 6F 72 20 61 20 73 70 65 63 69 66 69 65 64 20 70 y has occurred for a specified p 000019E0 65 72 69 6F 64 20 6F 66 20 74 69 6D 65 2E 20 20 53 65 74 20 74 68 65 20 61 6D 6F 75 6E 74 20 6F eriod of time. Set the amount o 00001A00 66 20 74 69 6D 65 20 61 74 20 74 68 65 20 22 49 64 6C 65 20 54 69 6D 65 2D 4F 75 74 22 20 6F 70 f time at the "Idle Time-Out" op 00001A20 74 69 6F 6E 2E 0A 0A 54 6F 20 73 70 65 63 69 66 79 20 74 68 65 20 6C 69 66 65 20 63 6C 61 73 73 tion.◙◙To specify the life class 00001A40 2C 20 68 69 67 68 6C 69 67 68 74 20 74 68 65 20 61 70 70 72 6F 70 72 69 61 74 65 20 6F 70 74 69 , highlight the appropriate opti 00001A60 6F 6E 20 61 6E 64 20 70 72 65 73 73 20 74 68 65 20 53 45 4C 45 43 54 20 6B 65 79 2E 0A 0A 20 20 on and press the SELECT key.◙◙ 00001A80 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 00001AA0 20 20 20 20 20 20 20 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 00 00 00 00 00 00 00 00 06 Page 1 of 1........♠ 00001AC0 0C 0F 37 0D 35 00 02 02 01 00 02 00 00 9F 01 20 20 20 20 20 20 20 20 20 20 20 20 20 45 44 49 54 ♀☼7♪5.☻☻☺.☻..ƒ☺ EDIT 00001AE0 20 4C 49 4E 45 20 49 44 4C 45 20 54 49 4D 45 2D 4F 55 54 20 48 45 4C 50 0A 0A 54 68 65 20 22 49 LINE IDLE TIME-OUT HELP◙◙The "I 00001B00 64 6C 65 20 54 69 6D 65 2D 4F 75 74 22 20 6F 70 74 69 6F 6E 20 61 6C 6C 6F 77 73 20 79 6F 75 20 dle Time-Out" option allows you 00001B20 74 6F 20 73 70 65 63 69 66 79 20 68 6F 77 20 6C 6F 6E 67 20 61 20 63 6F 6E 6E 65 63 74 69 6F 6E to specify how long a connection 00001B40 20 63 61 6E 20 72 65 6D 61 69 6E 20 69 6E 61 63 74 69 76 65 20 62 65 66 6F 72 65 20 62 65 69 6E can remain inactive before bein 00001B60 67 20 61 75 74 6F 6D 61 74 69 63 61 6C 6C 79 20 74 65 72 6D 69 6E 61 74 65 64 2E 0A 0A 49 66 20 g automatically terminated.◙◙If 00001B80 79 6F 75 20 73 65 6C 65 63 74 65 64 20 74 68 65 20 22 54 69 6D 65 64 22 20 6F 70 74 69 6F 6E 20 you selected the "Timed" option 00001BA0 66 6F 72 20 74 68 65 20 22 4C 69 66 65 20 43 6C 61 73 73 22 20 65 6E 74 72 79 2C 20 79 6F 75 20 for the "Life Class" entry, you 00001BC0 6D 75 73 74 20 73 70 65 63 69 66 79 20 74 68 65 20 22 49 64 6C 65 20 54 69 6D 65 2D 4F 75 74 2E must specify the "Idle Time-Out. 00001BE0 22 0A 0A 54 6F 20 73 70 65 63 69 66 79 20 74 68 65 20 22 49 64 6C 65 20 54 69 6D 65 2D 4F 75 74 "◙◙To specify the "Idle Time-Out 00001C00 2C 22 20 74 79 70 65 20 74 68 65 20 6E 75 6D 62 65 72 20 6F 66 20 6D 69 6E 75 74 65 73 20 61 6E ," type the number of minutes an 00001C20 64 20 70 72 65 73 73 20 74 68 65 20 53 45 4C 45 43 54 20 6B 65 79 2E 0A 0A 20 20 20 20 20 20 20 d press the SELECT key.◙◙ 00001C40 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 00001C60 20 20 50 61 67 65 20 31 20 6F 66 20 31 0A E8 1D 00 00 00 00 00 00 06 08 0F 40 0D 3E 00 02 02 01 Page 1 of 1◙Φ↔......♠◘☼@♪>.☻☻☺ 00001C80 00 02 00 00 D1 01 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 45 .☻..╤☺ E 00001CA0 44 49 54 20 4C 49 4E 45 20 48 45 4C 50 0A 0A 54 68 65 20 6F 70 74 69 6F 6E 73 20 69 6E 20 74 68 DIT LINE HELP◙◙The options in th 00001CC0 65 20 22 45 64 69 74 20 4C 69 6E 65 22 20 77 69 6E 64 6F 77 20 61 6C 6C 6F 77 20 79 6F 75 20 74 e "Edit Line" window allow you t 00001CE0 6F 20 63 6F 6E 66 69 67 75 72 65 20 65 61 63 68 20 6C 69 6E 65 20 66 6F 72 20 65 61 63 68 20 6F o configure each line for each o 00001D00 66 20 74 68 65 20 72 65 6D 6F 74 65 20 64 72 69 76 65 72 73 20 79 6F 75 20 73 65 6C 65 63 74 65 f the remote drivers you selecte 00001D20 64 20 64 75 72 69 6E 67 20 74 68 65 20 62 72 69 64 67 65 20 63 6F 6E 66 69 67 75 72 61 74 69 6F d during the bridge configuratio 00001D40 6E 20 70 72 6F 63 65 73 73 2E 0A 0A 49 66 20 79 6F 75 20 68 61 76 65 20 61 20 43 4F 4D 31 2F 43 n process.◙◙If you have a COM1/C 00001D60 4F 4D 32 20 6F 72 20 58 2E 32 35 20 63 6F 6D 6D 75 6E 69 63 61 74 69 6F 6E 20 62 6F 61 72 64 2C OM2 or X.25 communication board, 00001D80 20 79 6F 75 20 6F 6E 6C 79 20 6E 65 65 64 20 74 6F 20 63 6F 6E 66 69 67 75 72 65 20 6F 6E 65 20 you only need to configure one 00001DA0 6C 69 6E 65 2E 0A 0A 49 66 20 79 6F 75 20 68 61 76 65 20 61 20 57 4E 49 4D 20 63 6F 6D 6D 75 6E line.◙◙If you have a WNIM commun 00001DC0 69 63 61 74 69 6F 6E 20 62 6F 61 72 64 2C 20 79 6F 75 20 77 69 6C 6C 20 6E 65 65 64 20 74 6F 20 ication board, you will need to 00001DE0 66 69 6C 6C 20 6F 75 74 20 74 68 69 73 20 66 6F 72 6D 20 66 6F 72 20 65 61 63 68 20 6F 66 20 74 fill out this form for each of t 00001E00 68 65 20 66 6F 75 72 20 6C 69 6E 65 73 20 61 76 61 69 6C 61 62 6C 65 2E 0A 0A 20 20 20 20 20 20 he four lines available.◙◙ 00001E20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 00001E40 20 20 20 20 20 20 20 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 32 00 00 00 00 FF 1B 00 00 05 Page 1 of 2.... ←..♣ 00001E60 0C 11 37 0F 35 00 02 02 01 00 02 00 00 0B 01 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 ♀◄7☼5.☻☻☺.☻..♂☺ 00001E80 20 20 45 44 49 54 20 4C 49 4E 45 20 48 45 4C 50 0A 0A 54 68 65 20 66 6F 6C 6C 6F 77 69 6E 67 20 EDIT LINE HELP◙◙The following 00001EA0 69 74 65 6D 73 20 69 6E 20 74 68 65 20 22 45 64 69 74 20 4C 69 6E 65 22 20 77 69 6E 64 6F 77 20 items in the "Edit Line" window 00001EC0 6D 61 79 20 62 65 20 63 6F 6E 66 69 67 75 72 65 64 3A 0A 0A 20 20 42 61 75 64 20 52 61 74 65 0A may be configured:◙◙ Baud Rate◙ 00001EE0 20 20 4D 6F 64 65 6D 20 54 79 70 65 0A 20 20 44 69 61 6C 20 4D 6F 64 65 0A 20 20 41 75 74 6F 20 Modem Type◙ Dial Mode◙ Auto 00001F00 43 6F 6E 6E 65 63 74 0A 20 20 50 68 6F 6E 65 20 4E 75 6D 62 65 72 0A 20 20 41 75 74 6F 20 49 44 Connect◙ Phone Number◙ Auto ID 00001F20 20 53 74 72 69 6E 67 0A 20 20 4C 69 66 65 20 43 6C 61 73 73 0A 20 20 49 64 6C 65 20 54 69 6D 65 String◙ Life Class◙ Idle Time 00001F40 2D 4F 75 74 0A 0A 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 -Out◙◙ 00001F60 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 00 00 00 00 00 00 Page 1 of 1...... 00001F80 00 00 07 0D 0E 36 0C 34 00 02 02 01 00 02 00 00 6B 01 20 20 20 20 20 20 20 20 20 20 20 20 20 45 ..•♪♫6♀4.☻☻☺.☻..k☺ E 00001FA0 44 49 54 20 4C 49 4E 45 20 53 41 56 45 20 43 48 41 4E 47 45 53 20 48 45 4C 50 0A 0A 54 68 65 20 DIT LINE SAVE CHANGES HELP◙◙The 00001FC0 22 53 61 76 65 20 43 68 61 6E 67 65 73 22 20 63 6F 6E 66 69 72 6D 61 74 69 6F 6E 20 62 6F 78 20 "Save Changes" confirmation box 00001FE0 61 6C 6C 6F 77 73 20 79 6F 75 20 74 6F 20 73 61 76 65 20 74 68 65 20 6C 69 6E 65 20 63 6F 6E 66 allows you to save the line conf 00002000 69 67 75 72 61 74 69 6F 6E 73 20 79 6F 75 20 6A 75 73 74 20 73 70 65 63 69 66 69 65 64 2E 0A 0A igurations you just specified.◙◙ 00002020 54 6F 20 73 61 76 65 20 74 68 65 20 6C 69 6E 65 20 63 6F 6E 66 69 67 75 72 61 74 69 6F 6E 73 2C To save the line configurations, 00002040 20 68 69 67 68 6C 69 67 68 74 20 22 59 65 73 22 20 61 6E 64 20 70 72 65 73 73 20 74 68 65 20 53 highlight "Yes" and press the S 00002060 45 4C 45 43 54 20 6B 65 79 2E 0A 0A 49 66 20 79 6F 75 20 64 6F 20 6E 6F 74 20 77 69 73 68 20 74 ELECT key.◙◙If you do not wish t 00002080 6F 20 73 61 76 65 20 74 68 65 20 6C 69 6E 65 20 63 6F 6E 66 69 67 75 72 61 74 69 6F 6E 73 2C 20 o save the line configurations, 000020A0 68 69 67 68 6C 69 67 68 74 20 22 4E 6F 22 20 61 6E 64 20 70 72 65 73 73 20 74 68 65 20 53 45 4C highlight "No" and press the SEL 000020C0 45 43 54 20 6B 65 79 2E 0A 0A 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 ECT key.◙◙ 000020E0 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 00 00 00 Page 1 of 1... 00002100 00 00 00 00 00 04 07 14 42 12 40 00 02 02 01 00 02 00 00 CA 02 20 20 20 20 20 20 20 20 20 20 20 .....♦•¶B↕@.☻☻☺.☻..╩☻ 00002120 20 20 20 20 20 20 20 20 45 44 49 54 20 53 48 45 4C 4C 20 49 44 20 53 54 52 49 4E 47 20 48 45 4C EDIT SHELL ID STRING HEL 00002140 50 0A 0A 54 68 65 20 22 49 44 20 53 74 72 69 6E 67 22 20 6F 70 74 69 6F 6E 20 61 6C 6C 6F 77 73 P◙◙The "ID String" option allows 00002160 20 79 6F 75 20 74 6F 20 73 70 65 63 69 66 79 20 74 68 65 20 49 44 20 73 74 72 69 6E 67 20 6F 66 you to specify the ID string of 00002180 20 74 68 65 20 62 72 69 64 67 65 20 79 6F 75 20 77 69 6C 6C 20 62 65 20 63 61 6C 6C 69 6E 67 2E the bridge you will be calling. 000021A0 20 20 54 68 69 73 20 69 64 65 6E 74 69 66 69 63 61 74 69 6F 6E 20 6D 61 79 20 62 65 20 66 6F 75 This identification may be fou 000021C0 6E 64 20 62 79 20 72 65 66 65 72 72 69 6E 67 20 74 6F 20 74 68 65 20 72 65 63 6F 72 64 20 6F 66 nd by referring to the record of 000021E0 20 74 68 65 20 49 44 20 73 74 72 69 6E 67 20 6D 61 64 65 20 64 75 72 69 6E 67 20 63 6F 6E 66 69 the ID string made during confi 00002200 67 75 72 61 74 69 6F 6E 20 6F 66 20 74 68 65 20 62 72 69 64 67 65 20 73 6F 66 74 77 61 72 65 2E guration of the bridge software. 00002220 0A 0A 54 68 65 20 72 65 6D 6F 74 65 20 77 6F 72 6B 73 74 61 74 69 6F 6E 20 73 68 65 6C 6C 20 61 ◙◙The remote workstation shell a 00002240 6E 64 20 74 68 65 20 62 72 69 64 67 65 20 73 6F 66 74 77 61 72 65 20 6D 75 73 74 20 68 61 76 65 nd the bridge software must have 00002260 20 69 64 65 6E 74 69 63 61 6C 20 49 44 20 73 74 72 69 6E 67 73 3B 20 6F 74 68 65 72 77 69 73 65 identical ID strings; otherwise 00002280 2C 20 74 68 65 20 72 65 6D 6F 74 65 20 77 6F 72 6B 73 74 61 74 69 6F 6E 20 77 69 6C 6C 20 6E 6F , the remote workstation will no 000022A0 74 20 62 65 20 61 62 6C 65 20 74 6F 20 65 73 74 61 62 6C 69 73 68 20 61 20 63 6F 6E 6E 65 63 74 t be able to establish a connect 000022C0 69 6F 6E 20 77 69 74 68 20 74 68 65 20 62 72 69 64 67 65 2E 0A 0A 49 6E 20 70 61 72 74 69 63 75 ion with the bridge.◙◙In particu 000022E0 6C 61 72 2C 20 74 68 65 20 6C 65 74 74 65 72 20 63 61 73 65 20 6F 66 20 74 68 65 20 49 44 20 73 lar, the letter case of the ID s 00002300 74 72 69 6E 67 20 6D 75 73 74 20 61 67 72 65 65 20 77 69 74 68 20 74 68 61 74 20 73 70 65 63 69 tring must agree with that speci 00002320 66 69 65 64 20 64 75 72 69 6E 67 20 62 72 69 64 67 65 20 63 6F 6E 66 69 67 75 72 61 74 69 6F 6E fied during bridge configuration 00002340 2E 20 20 22 41 42 43 22 20 61 6E 64 20 22 61 62 63 22 20 61 72 65 20 4E 4F 54 20 54 48 45 20 53 . "ABC" and "abc" are NOT THE S 00002360 41 4D 45 21 0A 0A 54 6F 20 73 70 65 63 69 66 79 2C 20 74 79 70 65 20 74 68 65 20 49 44 20 73 74 AME!◙◙To specify, type the ID st 00002380 72 69 6E 67 20 61 6E 64 20 70 72 65 73 73 20 74 68 65 20 53 45 4C 45 43 54 20 6B 65 79 2E 0A 0A ring and press the SELECT key.◙◙ 000023A0 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 000023C0 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 00 Page 1 of 1. 000023E0 00 00 00 00 00 00 00 06 0E 10 34 0E 32 00 02 02 01 00 02 00 00 A2 01 20 20 20 20 20 20 20 20 20 .......♠♫►4♫2.☻☻☺.☻..ó☺ 00002400 20 45 44 49 54 20 53 48 45 4C 4C 20 57 4F 52 4B 53 54 41 54 49 4F 4E 20 49 44 20 48 45 4C 50 20 EDIT SHELL WORKSTATION ID HELP 00002420 20 0A 0A 54 68 65 20 22 57 6F 72 6B 73 74 61 74 69 6F 6E 20 49 44 22 20 6F 70 74 69 6F 6E 20 61 ◙◙The "Workstation ID" option a 00002440 6C 6C 6F 77 73 20 79 6F 75 20 74 6F 20 73 70 65 63 69 66 79 20 74 68 65 20 6E 61 6D 65 20 79 6F llows you to specify the name yo 00002460 75 20 77 6F 75 6C 64 20 6C 69 6B 65 20 74 68 65 20 72 65 6D 6F 74 65 20 77 6F 72 6B 73 74 61 74 u would like the remote workstat 00002480 69 6F 6E 20 74 6F 20 62 65 20 6B 6E 6F 77 6E 20 62 79 3A 20 20 22 4A 6F 68 6E 27 73 20 63 6F 6D ion to be known by: "John's com 000024A0 70 75 74 65 72 22 20 6F 72 20 22 50 72 6F 76 6F 20 4F 66 66 69 63 65 2C 22 20 66 6F 72 20 65 78 puter" or "Provo Office," for ex 000024C0 61 6D 70 6C 65 2E 20 20 0A 0A 54 68 65 20 77 6F 72 6B 73 74 61 74 69 6F 6E 20 49 44 20 69 73 20 ample. ◙◙The workstation ID is 000024E0 64 69 73 70 6C 61 79 65 64 20 77 68 65 6E 20 79 6F 75 20 72 75 6E 20 74 68 65 20 4C 43 4F 4E 53 displayed when you run the LCONS 00002500 4F 4C 45 20 75 74 69 6C 69 74 79 2E 0A 0A 54 6F 20 73 70 65 63 69 66 79 20 74 68 65 20 77 6F 72 OLE utility.◙◙To specify the wor 00002520 6B 73 74 61 74 69 6F 6E 20 49 44 2C 20 74 79 70 65 20 74 68 65 20 63 68 6F 73 65 6E 20 69 64 65 kstation ID, type the chosen ide 00002540 6E 74 69 66 69 63 61 74 69 6F 6E 20 61 6E 64 20 70 72 65 73 73 20 74 68 65 20 53 45 4C 45 43 54 ntification and press the SELECT 00002560 20 6B 65 79 2E 0A 0A 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 key.◙◙ 00002580 20 20 20 20 20 20 20 20 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 20 00 00 00 00 00 00 00 Page 1 of 1 ....... 000025A0 00 06 0B 0F 39 0D 37 00 02 02 01 00 02 00 00 C2 01 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 .♠♂☼9♪7.☻☻☺.☻..┬☺ 000025C0 20 45 44 49 54 20 53 48 45 4C 4C 20 43 4F 4D 20 50 4F 52 54 20 48 45 4C 50 0A 0A 54 68 65 20 22 EDIT SHELL COM PORT HELP◙◙The " 000025E0 43 4F 4D 20 50 6F 72 74 22 20 6F 70 74 69 6F 6E 20 61 6C 6C 6F 77 73 20 79 6F 75 20 74 6F 20 73 COM Port" option allows you to s 00002600 70 65 63 69 66 79 20 77 68 69 63 68 20 43 4F 4D 20 70 6F 72 74 20 77 69 6C 6C 20 62 65 20 75 73 pecify which COM port will be us 00002620 65 64 20 62 79 20 74 68 65 20 72 65 6D 6F 74 65 20 73 68 65 6C 6C 2E 20 20 54 68 65 20 6E 75 6D ed by the remote shell. The num 00002640 62 65 72 20 79 6F 75 20 63 68 6F 6F 73 65 20 77 69 6C 6C 20 64 65 74 65 72 6D 69 6E 65 20 68 6F ber you choose will determine ho 00002660 77 20 79 6F 75 20 69 6E 73 74 61 6C 6C 20 74 68 65 20 73 65 72 69 61 6C 20 63 6F 6D 6D 75 6E 69 w you install the serial communi 00002680 63 61 74 69 6F 6E 20 70 6F 72 74 2E 0A 0A 54 6F 20 73 70 65 63 69 66 79 20 74 68 65 20 43 4F 4D cation port.◙◙To specify the COM 000026A0 20 70 6F 72 74 20 6E 75 6D 62 65 72 2C 20 70 72 65 73 73 20 74 68 65 20 53 45 4C 45 43 54 20 6B port number, press the SELECT k 000026C0 65 79 2E 20 54 77 6F 20 6F 70 74 69 6F 6E 73 20 77 69 6C 6C 20 61 70 70 65 61 72 20 6F 6E 20 74 ey. Two options will appear on t 000026E0 68 65 20 73 63 72 65 65 6E 3A 20 20 43 4F 4D 31 20 61 6E 64 20 43 4F 4D 32 2E 20 20 48 69 67 68 he screen: COM1 and COM2. High 00002700 6C 69 67 68 74 20 74 68 65 20 61 70 70 72 6F 70 72 69 61 74 65 20 70 6F 72 74 20 6E 75 6D 62 65 light the appropriate port numbe 00002720 72 20 61 6E 64 20 70 72 65 73 73 20 74 68 65 20 53 45 4C 45 43 54 20 6B 65 79 2E 0A 0A 20 20 20 r and press the SELECT key.◙◙ 00002740 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 00002760 20 20 20 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 00 00 00 00 00 00 00 00 04 08 14 3F 12 Page 1 of 1........♦◘¶?↕ 00002780 3D 00 02 02 01 00 02 00 00 74 02 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 45 44 49 =.☻☻☺.☻..t☻ EDI 000027A0 54 20 53 48 45 4C 4C 20 42 41 55 44 20 52 41 54 45 20 48 45 4C 50 0A 0A 54 68 65 20 22 42 61 75 T SHELL BAUD RATE HELP◙◙The "Bau 000027C0 64 20 52 61 74 65 22 20 6F 70 74 69 6F 6E 20 61 6C 6C 6F 77 73 20 79 6F 75 20 74 6F 20 73 65 6C d Rate" option allows you to sel 000027E0 65 63 74 20 74 68 65 20 62 61 75 64 20 72 61 74 65 20 66 6F 72 20 74 68 65 20 6D 6F 64 65 6D 20 ect the baud rate for the modem 00002800 61 74 20 74 68 65 20 72 65 6D 6F 74 65 20 77 6F 72 6B 73 74 61 74 69 6F 6E 2E 20 20 54 68 65 20 at the remote workstation. The 00002820 72 65 63 6F 6D 6D 65 6E 64 65 64 20 62 61 75 64 20 72 61 74 65 73 20 66 6F 72 20 79 6F 75 72 20 recommended baud rates for your 00002840 6D 6F 64 65 6D 20 61 72 65 20 6C 69 73 74 65 64 20 69 6E 20 74 68 65 20 6D 61 6E 75 61 6C 20 74 modem are listed in the manual t 00002860 68 61 74 20 63 61 6D 65 20 77 69 74 68 20 69 74 2E 0A 0A 49 66 20 79 6F 75 20 61 72 65 20 75 73 hat came with it.◙◙If you are us 00002880 69 6E 67 20 61 20 48 61 79 65 73 20 6F 72 20 63 6F 6D 70 61 74 69 62 6C 65 20 6D 6F 64 65 6D 2C ing a Hayes or compatible modem, 000028A0 20 73 65 74 20 69 74 73 20 62 61 75 64 20 72 61 74 65 20 74 6F 20 74 68 65 20 68 69 67 68 65 73 set its baud rate to the highes 000028C0 74 20 74 68 65 20 6D 6F 64 65 6D 20 77 69 6C 6C 20 73 75 70 70 6F 72 74 2E 0A 0A 49 66 20 79 6F t the modem will support.◙◙If yo 000028E0 75 20 61 72 65 20 75 73 69 6E 67 20 61 20 6D 6F 64 65 6D 20 74 68 61 74 20 69 73 20 6E 6F 74 20 u are using a modem that is not 00002900 61 20 48 61 79 65 73 20 6F 72 20 63 6F 6D 70 61 74 69 62 6C 65 2C 20 73 65 74 20 69 74 73 20 62 a Hayes or compatible, set its b 00002920 61 75 64 20 72 61 74 65 20 74 6F 20 74 68 65 20 68 69 67 68 65 73 74 20 63 6F 6D 6D 6F 6E 20 64 aud rate to the highest common d 00002940 65 6E 6F 6D 69 6E 61 74 6F 72 20 6F 66 20 61 6C 6C 20 74 68 65 20 6D 6F 64 65 6D 73 20 79 6F 75 enominator of all the modems you 00002960 20 61 72 65 20 75 73 69 6E 67 2E 0A 0A 54 6F 20 73 70 65 63 69 66 79 20 74 68 65 20 62 61 75 64 are using.◙◙To specify the baud 00002980 20 72 61 74 65 2C 20 68 69 67 68 6C 69 67 68 74 20 74 68 65 20 61 70 70 72 6F 70 72 69 61 74 65 rate, highlight the appropriate 000029A0 20 6F 70 74 69 6F 6E 20 61 6E 64 20 70 72 65 73 73 20 74 68 65 20 53 45 4C 45 43 54 20 6B 65 79 option and press the SELECT key 000029C0 2E 0A 0A 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 .◙◙ 000029E0 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 00 Page 1 of 1. 00002A00 00 00 00 00 00 00 00 04 06 14 44 12 42 00 02 02 01 00 02 00 00 C4 02 20 20 20 20 20 20 20 20 20 .......♦♠¶D↕B.☻☻☺.☻..─☻ 00002A20 20 20 20 20 20 20 20 20 20 20 20 45 44 49 54 20 53 48 45 4C 4C 20 4D 4F 44 45 4D 20 54 59 50 45 EDIT SHELL MODEM TYPE 00002A40 20 48 45 4C 50 0A 0A 54 68 65 20 22 4D 6F 64 65 6D 20 54 79 70 65 22 20 6F 70 74 69 6F 6E 20 61 HELP◙◙The "Modem Type" option a 00002A60 6C 6C 6F 77 73 20 79 6F 75 20 74 6F 20 73 70 65 63 69 66 79 20 77 68 65 74 68 65 72 20 74 68 65 llows you to specify whether the 00002A80 20 72 65 6D 6F 74 65 20 77 6F 72 6B 73 74 61 74 69 6F 6E 27 73 20 6D 6F 64 65 6D 20 69 73 20 61 remote workstation's modem is a 00002AA0 20 22 48 61 79 65 73 20 43 6F 6D 70 61 74 69 62 6C 65 22 20 6F 72 20 61 20 22 53 70 65 63 69 61 "Hayes Compatible" or a "Specia 00002AC0 6C 20 43 6F 6E 66 69 67 75 72 61 74 69 6F 6E 2E 22 0A 0A 49 66 20 79 6F 75 72 20 6D 6F 64 65 6D l Configuration."◙◙If your modem 00002AE0 20 69 73 20 6E 6F 74 20 61 20 48 61 79 65 73 20 6F 72 20 63 6F 6D 70 61 74 69 62 6C 65 2C 20 79 is not a Hayes or compatible, y 00002B00 6F 75 20 6D 75 73 74 20 73 65 6C 65 63 74 20 74 68 65 20 22 53 70 65 63 69 61 6C 20 43 6F 6E 66 ou must select the "Special Conf 00002B20 69 67 75 72 61 74 69 6F 6E 22 20 6F 70 74 69 6F 6E 2E 0A 0A 54 68 65 20 22 53 70 65 63 69 61 6C iguration" option.◙◙The "Special 00002B40 20 43 6F 6E 66 69 67 75 72 61 74 69 6F 6E 22 20 6F 70 74 69 6F 6E 20 61 6C 6C 6F 77 73 20 79 6F Configuration" option allows yo 00002B60 75 20 74 6F 20 75 73 65 20 61 6C 6D 6F 73 74 20 61 6E 79 20 6D 6F 64 65 6D 3B 20 68 6F 77 65 76 u to use almost any modem; howev 00002B80 65 72 2C 20 74 68 65 20 73 68 65 6C 6C 20 63 6F 6E 66 69 67 75 72 61 74 69 6F 6E 20 70 72 6F 63 er, the shell configuration proc 00002BA0 65 73 73 20 77 69 6C 6C 20 61 6C 6C 6F 77 20 79 6F 75 20 74 6F 20 73 70 65 63 69 66 79 20 6F 6E ess will allow you to specify on 00002BC0 6C 79 20 74 68 65 20 62 61 75 64 20 72 61 74 65 20 69 66 20 74 68 69 73 20 6F 70 74 69 6F 6E 20 ly the baud rate if this option 00002BE0 69 73 20 73 65 6C 65 63 74 65 64 2E 0A 0A 54 6F 20 73 65 6C 65 63 74 20 74 68 65 20 6D 6F 64 65 is selected.◙◙To select the mode 00002C00 6D 20 74 79 70 65 2C 20 70 72 65 73 73 20 74 68 65 20 53 45 4C 45 43 54 20 6B 65 79 2E 20 20 41 m type, press the SELECT key. A 00002C20 20 77 69 6E 64 6F 77 20 63 6F 6E 74 61 69 6E 69 6E 67 20 74 68 65 20 74 77 6F 20 6F 70 74 69 6F window containing the two optio 00002C40 6E 73 20 77 69 6C 6C 20 61 70 70 65 61 72 20 6F 6E 20 74 68 65 20 73 63 72 65 65 6E 2E 20 48 69 ns will appear on the screen. Hi 00002C60 67 68 6C 69 67 68 74 20 74 68 65 20 61 70 70 72 6F 70 72 69 61 74 65 20 6F 70 74 69 6F 6E 20 61 ghlight the appropriate option a 00002C80 6E 64 20 70 72 65 73 73 20 74 68 65 20 53 45 4C 45 43 54 20 6B 65 79 2E 0A 0A 20 20 20 20 20 20 nd press the SELECT key.◙◙ 00002CA0 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 00002CC0 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 00 00 00 00 00 Page 1 of 1..... 00002CE0 00 00 00 03 02 15 4B 13 49 00 02 02 01 00 02 00 00 BB 02 20 20 20 20 20 20 20 20 20 20 20 20 20 ...♥☻§K‼I.☻☻☺.☻..╗☻ 00002D00 20 20 20 20 20 20 20 20 20 20 20 20 20 20 45 44 49 54 20 53 48 45 4C 4C 20 4D 4F 44 45 4D 20 53 EDIT SHELL MODEM S 00002D20 54 52 49 4E 47 0A 0A 54 68 65 20 22 4D 6F 64 65 6D 20 53 74 72 69 6E 67 22 20 6F 70 74 69 6F 6E TRING◙◙The "Modem String" option 00002D40 20 61 6C 6C 6F 77 73 20 79 6F 75 20 74 6F 20 73 70 65 63 69 66 79 20 74 68 65 20 70 68 6F 6E 65 allows you to specify the phone 00002D60 20 6E 75 6D 62 65 72 20 6F 66 20 74 68 65 20 62 72 69 64 67 65 20 79 6F 75 20 61 72 65 20 64 69 number of the bridge you are di 00002D80 61 6C 69 6E 67 2E 0A 0A 49 66 20 79 6F 75 20 68 61 76 65 20 61 20 48 61 79 65 73 20 6F 72 20 63 aling.◙◙If you have a Hayes or c 00002DA0 6F 6D 70 61 74 69 62 6C 65 20 6D 6F 64 65 6D 2C 20 79 6F 75 20 6D 75 73 74 20 65 6E 74 65 72 20 ompatible modem, you must enter 00002DC0 74 68 65 20 70 68 6F 6E 65 20 6E 75 6D 62 65 72 20 6F 66 20 74 68 65 20 62 72 69 64 67 65 2E 0A the phone number of the bridge.◙ 00002DE0 0A 54 68 65 20 70 72 6F 6D 70 74 20 70 72 6F 76 69 64 65 73 20 61 20 70 6F 72 74 69 6F 6E 20 6F ◙The prompt provides a portion o 00002E00 66 20 74 68 65 20 63 6F 6D 6D 61 6E 64 20 73 74 72 69 6E 67 20 74 68 61 74 20 63 6F 72 72 65 73 f the command string that corres 00002E20 70 6F 6E 64 73 20 77 69 74 68 20 74 68 65 20 73 65 6C 65 63 74 65 64 20 62 61 75 64 20 72 61 74 ponds with the selected baud rat 00002E40 65 2E 20 20 54 68 69 73 20 70 6F 72 74 69 6F 6E 20 63 61 6E 6E 6F 74 20 62 65 20 65 64 69 74 65 e. This portion cannot be edite 00002E60 64 2E 0A 0A 59 6F 75 20 6D 61 79 20 75 73 65 20 61 20 76 61 72 69 65 74 79 20 6F 66 20 63 68 61 d.◙◙You may use a variety of cha 00002E80 72 61 63 74 65 72 73 20 28 75 70 20 74 6F 20 33 35 29 20 74 6F 20 63 6F 6D 70 6C 65 74 65 20 74 racters (up to 35) to complete t 00002EA0 68 65 20 63 6F 6D 6D 61 6E 64 20 73 74 72 69 6E 67 2E 20 20 52 65 66 65 72 20 74 6F 20 74 68 65 he command string. Refer to the 00002EC0 20 75 73 65 72 73 20 6D 61 6E 75 61 6C 73 20 70 72 6F 76 69 64 65 64 20 77 69 74 68 20 79 6F 75 users manuals provided with you 00002EE0 72 20 6D 6F 64 65 6D 20 66 6F 72 20 61 6E 20 65 78 70 6C 61 6E 61 74 69 6F 6E 20 6F 66 20 70 6F r modem for an explanation of po 00002F00 73 73 69 62 6C 65 20 63 6F 6D 6D 61 6E 64 20 73 74 72 69 6E 67 73 2E 0A 0A 41 64 64 20 74 68 65 ssible command strings.◙◙Add the 00002F20 20 70 68 6F 6E 65 20 6E 75 6D 62 65 72 20 6F 66 20 74 68 65 20 62 72 69 64 67 65 20 74 6F 20 74 phone number of the bridge to t 00002F40 68 69 73 20 73 74 72 69 6E 67 20 61 6E 64 20 70 72 65 73 73 20 74 68 65 20 53 45 4C 45 43 54 20 his string and press the SELECT 00002F60 6B 65 79 2E 0A 0A 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 key.◙◙ 00002F80 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 00002FA0 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 00 00 00 00 00 00 00 00 05 09 11 3D 0F 3B 00 02 02 01 Page 1 of 1........♣○◄=☼;.☻☻☺ 00002FC0 00 02 00 00 7A 01 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 45 44 49 .☻..z☺ EDI 00002FE0 54 20 53 48 45 4C 4C 20 48 45 4C 50 0A 0A 4F 70 74 69 6F 6E 73 20 69 6E 20 74 68 65 20 22 45 64 T SHELL HELP◙◙Options in the "Ed 00003000 69 74 20 53 68 65 6C 6C 22 20 77 69 6E 64 6F 77 20 61 6C 6C 6F 77 20 79 6F 75 20 74 6F 20 63 6F it Shell" window allow you to co 00003020 6E 66 69 67 75 72 65 20 74 68 65 20 72 65 6D 6F 74 65 20 77 6F 72 6B 73 74 61 74 69 6F 6E 20 73 nfigure the remote workstation s 00003040 68 65 6C 6C 2E 20 20 54 68 65 20 66 6F 6C 6C 6F 77 69 6E 67 20 73 69 78 20 69 74 65 6D 73 20 6D hell. The following six items m 00003060 61 79 20 62 65 20 63 6F 6E 66 69 67 75 72 65 64 3A 0A 0A 20 20 49 44 20 53 74 72 69 6E 67 0A 20 ay be configured:◙◙ ID String◙ 00003080 20 57 6F 72 6B 73 74 61 74 69 6F 6E 20 49 44 0A 20 20 43 4F 4D 20 50 6F 72 74 0A 20 20 42 61 75 Workstation ID◙ COM Port◙ Bau 000030A0 64 20 52 61 74 65 0A 20 20 4D 6F 64 65 6D 20 54 79 70 65 0A 20 20 4D 6F 64 65 6D 20 53 74 72 69 d Rate◙ Modem Type◙ Modem Stri 000030C0 6E 67 20 28 69 66 20 79 6F 75 20 61 72 65 20 75 73 69 6E 67 20 61 20 48 61 79 65 73 20 6F 72 20 ng (if you are using a Hayes or 000030E0 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 63 6F 6D 70 61 74 69 62 6C 65 20 6D 6F compatible mo 00003100 64 65 6D 29 0A 0A 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 dem)◙◙ 00003120 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 Page 1 of 1 00003140 00 00 00 00 00 00 00 00 06 0A 0F 3C 0D 3A 00 02 02 01 00 02 00 00 C1 01 20 20 20 20 20 20 20 20 ........♠◙☼<♪:.☻☻☺.☻..┴☺ 00003160 20 20 20 20 20 20 20 45 44 49 54 20 53 48 45 4C 4C 20 53 41 56 45 20 43 48 41 4E 47 45 53 20 48 EDIT SHELL SAVE CHANGES H 00003180 45 4C 50 0A 0A 54 68 65 20 22 53 61 76 65 20 43 68 61 6E 67 65 73 22 20 63 6F 6E 66 69 72 6D 61 ELP◙◙The "Save Changes" confirma 000031A0 74 69 6F 6E 20 62 6F 78 20 61 6C 6C 6F 77 73 20 79 6F 75 20 74 6F 20 73 61 76 65 20 74 68 65 20 tion box allows you to save the 000031C0 72 65 6D 6F 74 65 20 77 6F 72 6B 73 74 61 74 69 6F 6E 20 63 6F 6E 66 69 67 75 72 61 74 69 6F 6E remote workstation configuration 000031E0 73 20 79 6F 75 20 6A 75 73 74 20 73 70 65 63 69 66 69 65 64 2E 0A 0A 54 6F 20 73 61 76 65 20 74 s you just specified.◙◙To save t 00003200 68 65 20 63 75 72 72 65 6E 74 20 63 6F 6E 66 69 67 75 72 61 74 69 6F 6E 20 69 6E 66 6F 72 6D 61 he current configuration informa 00003220 74 69 6F 6E 2C 20 68 69 67 68 6C 69 67 68 74 20 22 59 65 73 22 20 61 6E 64 20 70 72 65 73 73 20 tion, highlight "Yes" and press 00003240 74 68 65 20 53 45 4C 45 43 54 20 6B 65 79 2E 0A 0A 49 66 20 79 6F 75 20 64 6F 20 6E 6F 74 20 77 the SELECT key.◙◙If you do not w 00003260 69 73 68 20 74 6F 20 73 61 76 65 20 74 68 65 20 63 6F 6E 66 69 67 75 72 61 74 69 6F 6E 73 2C 20 ish to save the configurations, 00003280 68 69 67 68 6C 69 67 68 74 20 22 4E 6F 22 20 61 6E 64 20 70 72 65 73 73 20 74 68 65 20 53 45 4C highlight "No" and press the SEL 000032A0 45 43 54 20 6B 65 79 2E 20 20 54 68 65 20 22 45 64 69 74 20 53 68 65 6C 6C 22 20 77 69 6E 64 6F ECT key. The "Edit Shell" windo 000032C0 77 20 77 69 6C 6C 20 72 65 61 70 70 65 61 72 20 6F 6E 20 74 68 65 20 73 63 72 65 65 6E 2E 0A 0A w will reappear on the screen.◙◙ 000032E0 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 00003300 20 20 20 20 20 20 20 20 20 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 3E 35 00 00 00 00 00 Page 1 of 1>5..... 00003320 00 06 06 10 44 0E 42 00 02 02 01 00 02 00 00 7C 02 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 .♠♠►D♫B.☻☻☺.☻..|☻ 00003340 20 20 20 20 20 20 20 20 20 20 20 20 20 46 49 4C 45 4E 41 4D 45 20 48 45 4C 50 0A 0A 45 6E 74 65 FILENAME HELP◙◙Ente 00003360 72 20 74 68 65 20 6E 61 6D 65 20 6F 66 20 74 68 65 20 66 69 6C 65 20 28 4F 53 2C 20 42 52 49 44 r the name of the file (OS, BRID 00003380 47 45 2C 20 6F 72 20 49 50 58 29 20 74 68 61 74 20 79 6F 75 20 77 61 6E 74 20 74 6F 20 63 6F 6E GE, or IPX) that you want to con 000033A0 66 69 67 75 72 65 2E 20 54 68 65 20 66 69 6C 65 20 6E 61 6D 65 20 73 68 6F 75 6C 64 20 69 6E 63 figure. The file name should inc 000033C0 6C 75 64 65 20 74 68 65 20 76 6F 6C 75 6D 65 20 6E 61 6D 65 20 28 4F 53 45 58 45 2D 31 2C 20 53 lude the volume name (OSEXE-1, S 000033E0 48 47 45 4E 2D 31 2C 20 42 52 47 45 4E 2D 32 2C 20 65 74 63 2E 29 20 66 6F 6C 6C 6F 77 65 64 20 HGEN-1, BRGEN-2, etc.) followed 00003400 62 79 20 61 20 63 6F 6C 6F 6E 20 28 3A 29 20 66 6F 6C 6C 6F 77 65 64 20 62 79 20 74 68 65 20 61 by a colon (:) followed by the a 00003420 63 74 75 61 6C 20 66 69 6C 65 20 6E 61 6D 65 20 69 6E 63 6C 75 64 69 6E 67 20 74 68 65 20 65 78 ctual file name including the ex 00003440 74 65 6E 74 69 6F 6E 20 28 4E 45 54 24 4F 53 2E 45 58 31 29 2E 20 20 0A 0A 4E 4F 54 45 3A 20 49 tention (NET$OS.EX1). ◙◙NOTE: I 00003460 66 20 79 6F 75 20 61 72 65 20 63 6F 6E 66 69 67 75 72 69 6E 67 20 61 20 73 70 6C 69 74 20 4F 53 f you are configuring a split OS 00003480 20 28 61 20 4E 45 54 24 4F 53 20 66 69 6C 65 20 74 68 61 74 20 69 73 20 6F 6E 20 32 20 64 69 73 (a NET$OS file that is on 2 dis 000034A0 6B 73 20 61 73 20 4E 45 54 24 4F 53 2E 45 58 31 20 61 6E 64 20 4E 45 54 24 4F 53 2E 45 58 32 29 ks as NET$OS.EX1 and NET$OS.EX2) 000034C0 20 79 6F 75 20 6D 75 73 74 20 75 73 65 20 74 68 65 20 63 6F 6D 6D 61 6E 64 20 6C 69 6E 65 20 66 you must use the command line f 000034E0 6F 72 6D 61 74 3A 20 41 52 43 4F 4E 46 49 47 20 4F 53 45 58 45 2D 31 3A 4E 45 54 24 4F 53 2E 45 ormat: ARCONFIG OSEXE-1:NET$OS.E 00003500 58 31 20 68 65 6C 70 76 6F 6C 20 53 2E 20 20 59 6F 75 20 6D 75 73 74 20 72 65 70 6C 61 63 65 20 X1 helpvol S. You must replace 00003520 22 68 65 6C 70 76 6F 6C 22 20 77 69 74 68 20 74 68 65 20 6E 61 6D 65 20 6F 66 20 74 68 65 20 76 "helpvol" with the name of the v 00003540 6F 6C 75 6D 65 20 77 68 69 63 68 20 63 6F 6E 74 61 69 6E 73 20 74 68 65 20 66 69 6C 65 20 41 52 olume which contains the file AR 00003560 43 4F 4E 46 49 47 2E 48 4C 50 2E 0A 0A 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 CONFIG.HLP.◙◙ 00003580 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 000035A0 20 20 50 61 67 65 20 31 20 6F 66 20 32 00 00 00 00 AA 32 00 00 06 0B 10 3A 0E 38 00 02 02 01 00 Page 1 of 2....¬2..♠♂►:♫8.☻☻☺. 000035C0 02 00 00 6B 01 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 46 49 4C 45 4E ☻..k☺ FILEN 000035E0 41 4D 45 20 48 45 4C 50 0A 0A 4E 4F 54 45 3A 20 59 6F 75 20 6D 61 79 20 4E 4F 54 20 73 70 65 63 AME HELP◙◙NOTE: You may NOT spec 00003600 69 66 79 20 61 20 64 72 69 76 65 20 6C 65 74 74 65 72 20 28 41 3A 42 52 49 44 47 45 2E 45 58 45 ify a drive letter (A:BRIDGE.EXE 00003620 29 20 61 74 20 74 68 69 73 20 70 72 6F 6D 70 74 21 0A 0A 56 61 6C 69 64 20 65 6E 74 72 69 65 73 ) at this prompt!◙◙Valid entries 00003640 20 77 6F 75 6C 64 20 69 6E 63 6C 75 64 65 3A 0A 20 20 20 20 20 53 48 47 45 4E 2D 32 3A 49 50 58 would include:◙ SHGEN-2:IPX 00003660 2E 43 4F 4D 0A 20 20 20 20 20 42 52 47 45 4E 2D 31 3A 42 52 49 44 47 45 2E 45 58 45 0A 0A 54 6F .COM◙ BRGEN-1:BRIDGE.EXE◙◙To 00003680 20 63 6F 6E 66 69 67 75 72 65 20 61 20 73 70 6C 69 74 20 4F 53 20 66 69 6C 65 20 79 6F 75 20 6D configure a split OS file you m 000036A0 69 67 68 74 20 74 79 70 65 20 28 66 72 6F 6D 20 74 68 65 20 44 4F 53 20 63 6F 6D 6D 61 6E 64 20 ight type (from the DOS command 000036C0 6C 69 6E 65 20 70 72 6F 6D 70 74 29 3A 0A 20 20 20 20 20 41 52 43 4F 4E 46 49 47 20 4F 53 45 58 line prompt):◙ ARCONFIG OSEX 000036E0 45 2D 31 3A 4E 45 54 24 4F 53 2E 45 58 31 20 42 52 55 54 49 4C 53 20 53 0A 0A 20 20 20 20 20 20 E-1:NET$OS.EX1 BRUTILS S◙◙ 00003700 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 00003720 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 32 00 00 00 00 00 00 00 00 07 0D 0D 35 0B 33 00 02 Page 1 of 2........•♪♪5♂3.☻ 00003740 02 01 00 02 00 00 82 01 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 53 45 4C 45 43 54 20 ☻☺.☻..é☺ SELECT 00003760 4C 49 4E 45 20 48 45 4C 50 0A 0A 54 68 65 20 22 53 65 6C 65 63 74 20 4C 69 6E 65 22 20 77 69 6E LINE HELP◙◙The "Select Line" win 00003780 64 6F 77 20 61 6C 6C 6F 77 73 20 79 6F 75 20 74 6F 20 73 70 65 63 69 66 79 20 74 68 65 20 6C 69 dow allows you to specify the li 000037A0 6E 65 20 79 6F 75 20 77 69 73 68 20 74 6F 20 63 6F 6E 66 69 67 75 72 65 2E 20 54 68 69 73 20 77 ne you wish to configure. This w 000037C0 69 6E 64 6F 77 20 61 70 70 65 61 72 73 20 6F 6E 6C 79 20 69 66 20 79 6F 75 20 61 72 65 20 69 6E indow appears only if you are in 000037E0 73 74 61 6C 6C 69 6E 67 20 61 20 57 4E 49 4D 20 63 6F 6D 6D 75 6E 69 63 61 74 69 6F 6E 20 62 6F stalling a WNIM communication bo 00003800 61 72 64 2E 0A 0A 54 6F 20 73 70 65 63 69 66 79 20 74 68 65 20 6C 69 6E 65 20 6E 75 6D 62 65 72 ard.◙◙To specify the line number 00003820 2C 20 68 69 67 68 6C 69 67 68 74 20 74 68 65 20 6C 69 6E 65 20 79 6F 75 20 77 61 6E 74 20 74 6F , highlight the line you want to 00003840 20 63 6F 6E 66 69 67 75 72 65 20 61 6E 64 20 70 72 65 73 73 20 74 68 65 20 53 45 4C 45 43 54 20 configure and press the SELECT 00003860 6B 65 79 2E 0A 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 key.◙ 00003880 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 000038A0 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 50 P 000038C0 61 67 65 20 31 20 6F 66 20 31 00 00 00 00 00 00 00 00 04 06 14 43 12 41 00 02 02 01 00 02 00 00 age 1 of 1........♦♠¶C↕A.☻☻☺.☻.. 000038E0 4E 02 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 4D 41 49 4E 20 N☻ MAIN 00003900 4D 45 4E 55 20 48 45 4C 50 0A 0A 54 68 65 20 22 4D 61 69 6E 20 4D 65 6E 75 22 20 6F 70 74 69 6F MENU HELP◙◙The "Main Menu" optio 00003920 6E 20 61 6C 6C 6F 77 73 20 79 6F 75 20 74 6F 20 73 70 65 63 69 66 79 20 77 68 65 74 68 65 72 20 n allows you to specify whether 00003940 79 6F 75 20 77 61 6E 74 20 74 6F 20 63 6F 6E 66 69 67 75 72 65 20 74 68 65 20 62 72 69 64 67 65 you want to configure the bridge 00003960 20 73 65 72 76 65 72 20 6F 72 20 61 20 70 61 72 74 69 63 75 6C 61 72 20 6C 69 6E 65 2E 20 20 54 server or a particular line. T 00003980 68 65 20 73 63 72 65 65 6E 20 64 69 73 70 6C 61 79 73 20 74 68 65 20 66 6F 6C 6C 6F 77 69 6E 67 he screen displays the following 000039A0 20 74 77 6F 20 6F 70 74 69 6F 6E 73 3A 0A 0A 43 4F 4E 46 49 47 55 52 45 20 42 52 49 44 47 45 20 two options:◙◙CONFIGURE BRIDGE 000039C0 53 45 52 56 45 52 0A 20 20 20 20 20 54 68 69 73 20 6F 70 74 69 6F 6E 20 61 6C 6C 6F 77 73 20 79 SERVER◙ This option allows y 000039E0 6F 75 20 74 6F 20 63 6F 6E 66 69 67 75 72 65 20 74 68 65 20 70 61 72 61 6D 65 74 65 72 73 20 6F ou to configure the parameters o 00003A00 66 20 74 68 65 20 20 20 20 20 20 20 20 62 72 69 64 67 65 2E 0A 0A 43 4F 4E 46 49 47 55 52 45 20 f the bridge.◙◙CONFIGURE 00003A20 41 20 50 41 52 54 49 43 55 4C 41 52 20 4C 49 4E 45 0A 20 20 20 20 20 54 68 69 73 20 6F 70 74 69 A PARTICULAR LINE◙ This opti 00003A40 6F 6E 20 61 6C 6C 6F 77 73 20 79 6F 75 20 74 6F 20 73 70 65 63 69 66 79 20 70 61 72 61 6D 65 74 on allows you to specify paramet 00003A60 65 72 73 20 66 6F 72 20 69 6E 64 69 76 69 64 75 61 6C 20 20 20 20 20 20 6C 69 6E 65 73 2E 0A 20 ers for individual lines.◙ 00003A80 20 0A 54 6F 20 73 70 65 63 69 66 79 20 77 68 69 63 68 20 63 6F 6E 66 69 67 75 72 61 74 69 6F 6E ◙To specify which configuration 00003AA0 20 79 6F 75 20 77 61 6E 74 20 74 6F 20 65 64 69 74 2C 20 68 69 67 68 6C 69 67 68 74 20 74 68 65 you want to edit, highlight the 00003AC0 20 61 70 70 72 6F 70 72 69 61 74 65 20 6F 70 74 69 6F 6E 20 61 6E 64 20 70 72 65 73 73 20 74 68 appropriate option and press th 00003AE0 65 20 53 45 4C 45 43 54 20 6B 65 79 2E 0A 20 0A 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 e SELECT key.◙ ◙ 00003B00 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 00003B20 20 20 20 20 20 50 61 67 65 20 31 20 6F 66 20 31 Page 1 of 1