              NOVELL TECHNICAL INFORMATION DOCUMENT

TITLE:              Patched UPS.NLM for NetWare v3.10
DOCUMENT ID:        TID000414
DOCUMENT REVISION:  A
DATE:               01JUL93
ALERT STATUS:       Yellow
INFORMATION TYPE:   Symptom Solution
README FOR:         UPS.EXE

NOVELL PRODUCT and VERSION:
NetWare Pre 3.11 and 2.2

ABSTRACT:
This file contains the UPS.NLM for NetWare v3.10. This UPS.NLM revision
corrects an interrupt sharing conflict between ADIC's DCB.DSK and the
UPS.NLM.
_________________________________________________________________

DISCLAIMER
THE ORIGIN OF THIS INFORMATION MAY BE INTERNAL OR EXTERNAL TO NOVELL. 
NOVELL MAKES EVERY EFFORT WITHIN ITS MEANS TO VERIFY THIS INFORMATION. 
HOWEVER, THE INFORMATION PROVIDED IN THIS DOCUMENT IS FOR YOUR INFORMATION
ONLY.  NOVELL MAKES NO EXPLICIT OR IMPLIED CLAIMS TO THE VALIDITY OF THIS
INFORMATION.
_________________________________________________________________

Self-Extracting File Name:  UPS.EXE

Files Included     Size     Date        Time

     UPS.TXT          (This File)
     UPS.NLM      10595   12-18-90      7:57a


This README file of UPS.EXE accompanies UPS.NLM for NetWare v3.10.

This revision of UPS.NLM corrects an interrupt sharing conflict between
ADIC's DCB.DSK AND UPS.NLM in NetWare 386 version 3.10.  To implement this
fix, you must follow the instructions as shown below and obtain the most
recent DCB.DSK file from ADIC.

To install this utility:

1)    Flag UPS.NLM as SRW (Sharable Read Write) in the SYSTEM directory.

2)    Rename UPS.NLM to UPS.old in the SYSTEM directory for backup
purposes.

3)    Copy UPS.NLM to the SYSTEM directory on your system.

4)    Flag the new copy of UPS.NLM back to SRO (Sharable Read-Only).