; Mylex EISA 32-bit Ethernet LAN Adapter
;
; (C)Copyright Mylex Corp., 1989-1992
; All Rights Reserved.
;
; 07/20/92 v2.0
; 10/25/93 v2.1
BOARD
ID = "MLX0010"
NAME = "Mylex LNE390A EISA 32-bit Ethernet LAN Adapter"
MFR = "Mylex"
CATEGORY = "NET"
SLOT = EISA
READID = YES
DISABLE = SUPPORTED
IOPORT(1)= 0zC84h
IOPORT(2)= 0zC90h
JUMPER(1) = 8
NAME = "JB4"
JTYPE = TRIPOLE
FACTORY = LOC(8-1) 11111111
FUNCTION = "Ethernet Connector Type"
TYPE = "NET"
CHOICE = "J3 BNC Thinwire connnection"
FREE
INIT = JUMPER(1) LOC(8-1) 11111111
CHOICE = "J4 DIX Thickwire connection"
FREE
INIT = JUMPER(1) LOC(8-1) 00000000
FUNCTION = "Shared RAM"
CHOICE = "RAM @ D0000 (Workstation or Fileserver)"
LINK
MEMORY = 64K
ADDRESS = 0d0000h
MEMTYPE = oth
SIZE = dword
CACHE = no
INIT = IOPORT(1) 00000001
INIT = IOPORT(2) LOC(2 1 0) 110
CHOICE = "RAM @ FD0000 (Fileserver Only below 16MB)"
LINK
MEMORY = 64K
ADDRESS = 0fd0000h
MEMTYPE = oth
SIZE = dword
CACHE = no
INIT = IOPORT(1) 00000001
INIT = IOPORT(2) LOC(2 1 0) 010
CHOICE = "RAM @ FE0000 (Fileserver Only below 16MB)"
LINK
MEMORY = 64K
ADDRESS = 0fe0000h
MEMTYPE = oth
SIZE = dword
CACHE = no
INIT = IOPORT(1) 00000001
INIT = IOPORT(2) LOC(2 1 0) 001
CHOICE = "RAM @ FF0000 (Fileserver Only below 16MB)"
LINK
MEMORY = 64K
ADDRESS = 0ff0000h
MEMTYPE = oth
SIZE = dword
CACHE = no
INIT = IOPORT(1) 00000001
INIT = IOPORT(2) LOC(2 1 0) 000
CHOICE = "RAM @ FFC0000 (Fileserver Only 16MB & Above)"
LINK
MEMORY = 64K
ADDRESS = 0ffc0000h
MEMTYPE = oth
SIZE = dword
CACHE = no
INIT = IOPORT(1) 00000001
INIT = IOPORT(2) LOC(2 1 0) 101
CHOICE = "RAM @ FFE0000 (Fileserver Only 16MB & Above)"
LINK
MEMORY = 64K
ADDRESS = 0ffe0000h
MEMTYPE = oth
SIZE = dword
CACHE = no
INIT = IOPORT(1) 00000001
INIT = IOPORT(2) LOC(2 1 0) 100
CHOICE = "RAM @ FFF0000 (Fileserver Only 16MB & Above)"
LINK
MEMORY = 64K
ADDRESS = 0fff0000h
MEMTYPE = oth
SIZE = dword
CACHE = no
INIT = IOPORT(1) 00000001
INIT = IOPORT(2) LOC(2 1 0) 011
FUNCTION = "Base I/O Address"
CHOICE = "Slot Specific I/O"
DISABLE = YES
LINK
PORT = 0z000h-0z01fh STEP = 1 COUNT = 32
FUNCTION = "LNE390A Interrupt"
CHOICE = "Interrupt 3"
FREE
IRQ = 3
SHARE = NO
TRIGGER = EDGE
INIT = IOPORT(1) 00000001
INIT = IOPORT(2) LOC(5 4 3) 111
CHOICE = "Interrupt 5"
FREE
IRQ = 5
SHARE = NO
TRIGGER = EDGE
INIT = IOPORT(1) 00000001
INIT = IOPORT(2) LOC(5 4 3) 110
CHOICE = "Interrupt 7"
FREE
IRQ = 7
SHARE = NO
TRIGGER = EDGE
INIT = IOPORT(1) 00000001
INIT = IOPORT(2) LOC(5 4 3) 101
CHOICE = "Interrupt 9"
FREE
IRQ = 9
SHARE = NO
TRIGGER = EDGE
INIT = IOPORT(1) 00000001
INIT = IOPORT(2) LOC(5 4 3) 100
CHOICE = "Interrupt A"
FREE
IRQ = 10
SHARE = NO
TRIGGER = EDGE
INIT = IOPORT(1) 00000001
INIT = IOPORT(2) LOC(5 4 3) 011
CHOICE = "Interrupt B"
FREE
IRQ = 11
SHARE = NO
TRIGGER = EDGE
INIT = IOPORT(1) 00000001
INIT = IOPORT(2) LOC(5 4 3) 010
CHOICE = "Interrupt C"
FREE
IRQ = 12
SHARE = NO
TRIGGER = EDGE
INIT = IOPORT(1) 00000001
INIT = IOPORT(2) LOC(5 4 3) 001
CHOICE = "Interrupt F"
FREE
IRQ = 15
SHARE = NO
TRIGGER = EDGE
INIT = IOPORT(1) 00000001
INIT = IOPORT(2) LOC(5 4 3) 000