Metropoli BBS
VIEWER: !cci6001.cfg MODE: TEXT (ASCII)
;  Cache Computer EISA 32-bit Ethernet LAN Adapter
;
;  4/10/92 v1.0

BOARD
   ID = "CCI6001"
   NAME = "Cache Computer EISA Ethernet LAN Adapter"
   MFR = "Cache"
   CATEGORY = "NET"
   SLOT = EISA
   READID = YES
   DISABLE = SUPPORTED

IOPORT(1)= 0zC84h
	
IOPORT(2)= 0zC90h

FUNCTION = "Shared RAM"
   CHOICE = "32K RAM @ D0000 (Workstation or Fileserver)"
      LINK
         MEMORY = 32K  
            ADDRESS = 0d0000h
            MEMTYPE = oth
            SIZE = dword
            CACHE = no
            INIT = IOPORT(2) LOC(2-0) 110

   CHOICE = "32K RAM @ FF0000 (Fileserver Only)"
      LINK
         MEMORY = 32K  
            ADDRESS = 0ff0000h
            MEMTYPE = oth
            SIZE = dword
            CACHE = no
            INIT = IOPORT(2) LOC(2-0) 000

   CHOICE = "32K RAM @ FE0000 (Fileserver Only)"
      LINK
         MEMORY = 32K  
            ADDRESS = 0fe0000h
            MEMTYPE = oth
            SIZE = dword
            CACHE = no
            INIT = IOPORT(2) LOC(2-0) 001

   CHOICE = "32K RAM @ FD0000 (Fileserver Only)"
      LINK
         MEMORY = 32K  
            ADDRESS = 0fd0000h
            MEMTYPE = oth
            SIZE = dword
            CACHE = no
            INIT = IOPORT(2) LOC(2-0) 010

   CHOICE = "32K RAM @ FFF0000 (Fileserver Only)"
      LINK
         MEMORY = 32K  
            ADDRESS = 0fff0000h
            MEMTYPE = oth
            SIZE = dword
            CACHE = no
            INIT = IOPORT(2) LOC(2-0) 011

   CHOICE = "32K RAM @ FFE0000 (Fileserver Only)"
      LINK
         MEMORY = 32K  
            ADDRESS = 0ffe0000h
            MEMTYPE = oth
            SIZE = dword
            CACHE = no
            INIT = IOPORT(2) LOC(2-0) 100

   CHOICE = "32K RAM @ FFD0000 (Fileserver Only)"
      LINK
         MEMORY = 32K  
            ADDRESS = 0ffd0000h
            MEMTYPE = oth
            SIZE = dword
            CACHE = no
            INIT = IOPORT(2) LOC(2-0) 101

FUNCTION = "Base I/O Address"
   CHOICE = "Slot Specific I/O"
      DISABLE = YES
      LINK
         PORT = 0z000h-0z01fh  STEP = 1  COUNT = 32

FUNCTION = "Interrupt (IRQ)"
   CHOICE  = "Interrupt 3"
   FREE
	IRQ = 3
	   SHARE = NO
	   TRIGGER = EDGE
        INIT = IOPORT(1) 00000001
        INIT = IOPORT(2) LOC(5-3) 111

   CHOICE = "Interrupt 5"
   FREE
        IRQ = 5
	   SHARE = NO
	   TRIGGER = EDGE
        INIT = IOPORT(1) 00000001
        INIT = IOPORT(2) LOC(5-3) 110

   CHOICE = "Interrupt 9"
   FREE
        IRQ = 9
	   SHARE = NO
	   TRIGGER = EDGE
        INIT = IOPORT(1) 00000001
        INIT = IOPORT(2) LOC(5-3) 100

   CHOICE = "Interrupt A"
   FREE
        IRQ = 10
	   SHARE = NO
	   TRIGGER = EDGE
        INIT = IOPORT(1) 00000001
        INIT = IOPORT(2) LOC(5-3) 011
        
   CHOICE  = "Interrupt 7"
   FREE
	IRQ = 7
	   SHARE = NO
	   TRIGGER = EDGE
        INIT = IOPORT(1) 00000001
        INIT = IOPORT(2) LOC(5-3) 101

   CHOICE = "Interrupt B"
   FREE
        IRQ = 11
	   SHARE = NO
	   TRIGGER = EDGE
        INIT = IOPORT(1) 00000001
        INIT = IOPORT(2) LOC(5-3) 010

   CHOICE = "Interrupt C"
   FREE
        IRQ = 12
	   SHARE = NO
	   TRIGGER = EDGE
        INIT = IOPORT(1) 00000001
        INIT = IOPORT(2) LOC(5-3) 001

   CHOICE = "Interrupt F"
   FREE
        IRQ = 15
	   SHARE = NO
	   TRIGGER = EDGE
        INIT = IOPORT(1) 00000001
        INIT = IOPORT(2) LOC(5-3) 000

FUNCTION = "Network Port Cable Type"
   CHOICE = "10BaseT Twisted Pair Ethernet - RJ-45 Connector"
      LINK
            INIT = IOPORT(2) LOC(7-6) 00

   CHOICE = "10Base2 Thin Ethernet - BNC Connector"
      LINK
            INIT = IOPORT(2) LOC(7-6) 11

   CHOICE = "10Base5 Thick Ethernet - DB-15 Connector"
      LINK
            INIT = IOPORT(2) LOC(7-6) 10

[ RETURN TO DIRECTORY ]