; * * Future Domain TMC-7000EX SCSI Host Bus Adapter * * ;
; * * Future Domain Corporation * * ;
; * * Copyright (c) 1990-1992 * * ;
; * * All Rights Reserved * * ;
; * * Version 1.5 * * ;
; * * Part Number #84-000345 * * ;
;--------------------------------------------------------;
BOARD
ID = "WDC2001" ;Product ID
NAME = "Future Domain TMC-7000EX EISA SCSI Host Bus Adapter "
MFR = "Future Domain Corporation"
CATEGORY = "MSD" ;Mass Storage Device
SLOT = EISA ;Fits in EISA slot only
READID = YES ;EISA ID registers'values are valid
BUSMASTER = 50
IOCHECK = INVALID ;EISA IOCHKERR bit is not supported
DISABLE = UNSUPPORTED ;EISA ENABLE bit is not supported
COMMENTS = "Future Domain TMC-7000EX Configuration File Version 1.5"
HELP = "Future Domain Technical Support
2801 McGaw Ave. Irvine, CA 92714
(714) 253-0440 8AM-5PM (PST) "
IOPORT(1) = 0zC85h INITVAL = xxxxxxxxb ;AutoConfiguration Register 1
IOPORT(2) = 0zC86h INITVAL = xxxxxxxxb ;AutoConfiguration Register 2
IOPORT(3) = 0zC87h INITVAL = 0000xxxxb ;AutoConfiguration Register 3
FUNCTION = "Adapter Options"
TYPE = "CST,Future Domain Corp" ; Max of 40 characters, blank fill
SUBFUNCTION = "Protocol Mode" ; after terminating message with '$'
CHOICE = "DACB Protocol" ; Change CST to STD for Standard message
SUBTYPE = "DACB00"
FREE
PORT = 0zC80h-0zCFFh
INIT = IOPORT(3) LOC(3-0) 0001 ;Set EX in DACB Mode
CHOICE = "ASC Protocol, 300H"
SUBTYPE = "ASC300"
FREE
PORT = 0zC80h-0zCFFh
PORT = 300h-302h
INIT = IOPORT(3) LOC(3-0) 0110 ;Set EX in ASC Mode, 300H
CHOICE = "ASC Protocol, 310H"
SUBTYPE = "ASC310"
FREE
PORT = 0zC80h-0zCFFh
PORT = 310h-312h
INIT = IOPORT(3) LOC(3-0) 1000 ;Set EX in ASC Mode, 310H
CHOICE = "ASC Protocol, 320H"
SUBTYPE = "ASC320"
FREE
PORT = 0zC80h-0zCFFh
PORT = 320h-322h
INIT = IOPORT(3) LOC(3-0) 0100 ;Set EX in ASC Mode, 320H
CHOICE = "ASC Protocol, 340H"
SUBTYPE = "ASC340"
FREE
PORT = 0zC80h-0zCFFh
PORT = 340h-342h
INIT = IOPORT(3) LOC(3-0) 0010 ;Set EX in ASC Mode, 340H
CHOICE = "ASC Protocol, 350H"
SUBTYPE = "ASC350"
FREE
PORT = 0zC80h-0zCFFh
PORT = 350h-352h
INIT = IOPORT(3) LOC(3-0) 0000 ;Set EX in ASC Mode, 350H
CHOICE = "ASC Protocol, 360H"
SUBTYPE = "ASC360"
FREE
PORT = 0zC80h-0zCFFh
PORT = 360h-362h
INIT = IOPORT(3) LOC(3-0) 1010 ;Set EX in ASC Mode, 360H
CHOICE = "ASC Protocol, 370H"
SUBTYPE = "ASC370"
FREE
PORT = 0zC80h-0zCFFh
PORT = 370h-372h
INIT = IOPORT(3) LOC(3-0) 1100 ;Set EX in ASC Mode, 370H
CHOICE = "ASC Protocol, 380H"
SUBTYPE = "ASC380"
FREE
PORT = 0zC80h-0zCFFh
PORT = 380h-382h
INIT = IOPORT(3) LOC(3-0) 1110 ;Set EX in ASC Mode, 380H
SUBFUNCTION = "BIOS Address"
CHOICE = "0DC000H - 0DFFFFH"
FREE
INIT = IOPORT(1) LOC(3-0) 1000
CHOICE = "0D8000H - 0DBFFFH"
FREE
INIT = IOPORT(1) LOC(3-0) 0111
CHOICE = "0D4000H - 0D7FFFH"
FREE
INIT = IOPORT(1) LOC(3-0) 0110
CHOICE = "0D0000H - 0D3FFFH"
FREE
INIT = IOPORT(1) LOC(3-0) 0101
CHOICE = "0CC000H - 0CFFFFH"
FREE
INIT = IOPORT(1) LOC(3-0) 0100
CHOICE = "0C8000H - 0CBFFFH"
FREE
INIT = IOPORT(1) LOC(3-0) 0011
CHOICE = "0C4000H - 0C7FFFH"
FREE
INIT = IOPORT(1) LOC(3-0) 0010
CHOICE = "0C0000H - 0C3FFFH"
FREE
INIT = IOPORT(1) LOC(3-0) 0001
CHOICE = "Disabled"
FREE
INIT = IOPORT(1) LOC(3-0) 0000 ;Disable BIOS Access
SUBFUNCTION = "Interrupt Request Level"
CHOICE = "IRQ 14"
SUBTYPE = "IRQ14"
FREE
IRQ = 14
TRIGGER = EDGE
INIT = IOPORT(1) LOC(5-4) 10
CHOICE = "IRQ 15"
SUBTYPE = "IRQ15"
FREE
IRQ = 15
TRIGGER = EDGE
INIT = IOPORT(1) LOC(5-4) 11
CHOICE = "IRQ 12"
SUBTYPE = "IRQ12"
FREE
IRQ = 12
TRIGGER = EDGE
INIT = IOPORT(1) LOC(5-4) 01
CHOICE = "IRQ 10"
SUBTYPE = "IRQ10"
FREE
IRQ = 10
TRIGGER = EDGE
INIT = IOPORT(1) LOC(5-4) 00
SUBFUNCTION = "Bus Preempt Time"
CHOICE = "32 BCLKS"
FREE
INIT = IOPORT(1) LOC(7-6) 01
CHOICE = "64 BCLKS"
FREE
INIT = IOPORT(1) LOC(7-6) 10
FUNCTION = "SCSI Channel"
TYPE = "SCS,CHA"
SUBFUNCTION = "Adapter SCSI ID"
CHOICE = "SCSI ID = 7"
FREE
INIT = IOPORT(2) LOC(2-0) 111
CHOICE = "SCSI ID = 6"
FREE
INIT = IOPORT(2) LOC(2-0) 110
CHOICE = "SCSI ID = 5"
FREE
INIT = IOPORT(2) LOC(2-0) 101
CHOICE = "SCSI ID = 4"
FREE
INIT = IOPORT(2) LOC(2-0) 100
CHOICE = "SCSI ID = 3"
FREE
INIT = IOPORT(2) LOC(2-0) 011
CHOICE = "SCSI ID = 2"
FREE
INIT = IOPORT(2) LOC(2-0) 010
CHOICE = "SCSI ID = 1"
FREE
INIT = IOPORT(2) LOC(2-0) 001
CHOICE = "SCSI ID = 0"
FREE
INIT = IOPORT(2) LOC(2-0) 000
SUBFUNCTION = "SCSI Parity"
CHOICE = "Enabled"
FREE
INIT = IOPORT(2) LOC(3) 1
CHOICE = "Disabled"
FREE
INIT = IOPORT(2) LOC(3) 0