Metropoli BBS
VIEWER: readme.os2 MODE: TEXT (ASCII)
The README.OS2 file contains:

        I.    Current release version for drivers and utilities.
		II.   How to install the STPRSCSI.ADD with OS/2 Device Driver
              installation utility. 
        III.  Device drivers and utilities usage of Parallel/SCSI Converters.
        IV.   Product tested list( Not all inclusive )
        V.    Diagnostic utility
        VI.   Technical tips( including how to install/upgrade OS2 to version
                3.0 Warp )

        All of the device drivers and utilities are fully compatible with
        both Parallel/SCSI Plus and Premium( AKA Polliwog ) models running
        under the OS/2 2.0, 2.1 and 3.0 ( Warp ).
        Please use this file as supplement to your installation/user guide.


I.      Current released device drivers and utilities version.
        ******************************************************

    OS2 directory--

        File name        Size  Date      Time        Version
        ===========================================================


        STPRSCSI ADD     33237 02-21-95   2:34p      v3.0
        STPRSCSI DDP       196 10-03-94   3:53p      v2.2
        STPRDISK DDP       163 10-03-94   3:53p      v2.2
        STPRCDRM DDP       236 10-03-94   3:52p      v2.2
        STPRASPI DDP       222 10-03-94   3:51p      v2.2


II.   How to install the STPRSCSI.ADD with OS2 Device Driver installation 
	  utility. 

      0.  Install the Parallel/SCSI Converters.  Please find the detail
          descriptions on the Installation/User Guide.
      1.  Boot the OS/2 system.
      2.  Open the "OS2 System" icon by double clicking the left mouse
          button.
      3.  Open the "System Setup" icon by double clicking the left mouse
          button.
      4.  Insert the distribution diskette come with the Converter.
      5.  Open the "Device Driver Install" icon by double clicking the 
          left mouse button.
      6.  Use the mouse to click on the "Change" word of "Source Directory".
          Type in the source directory as "A:\OS2" or "B:\OS2" and then click
          on the "Set" word.
      7.  Click the "Install" word to start the installation.
	  8.  A screen with "Parallel/SCSI Device Driver Profile...." message
          will then show up. 
      9.  Click on the Device Profiles you wish to install.
     10.  Click on "Exit" to exit the installation.  Now your device driver
          installation procedure is completed.  Re-boot the system to take
          effect.
          
      
III.    Device Driver and Utility Usage of Parallel/SCSI Converters             
		*********************************************************** 

        ==================================
        STPRSCSI.ADD Adapter Device Driver
        ==================================

          Installation Format:

                BASEDEV=STPRSCSI.SYS [/Dn] [/Wn] [/Sn] [/Zn] 
                        [/In] [!SM or /SM] [!DM or /SM]

                /Dn - define how many SCSI drives are attached.
                      n must be 1 - 7, if n is 1 only SCSI ID 0 drive
                        is checked, if n is 2 only SCSI ID 0, 1 drives
                        are checked.
                      Default value is 7.

                /Wn - define how many seconds to wait time for drive to 
                        be stable during POWER ON time.
                      n must be 0 - 1800.
                      Default value is 5.

                /Sn - set the starting search port access speed level for 
                      printer port. If this parameter is not specified, 
                      driver will try from the fastest speed level 0, and
                      then level 1, level 2 until level 9 automatically, 
                      If none can meet the port access speed, level 0 will
                      be assumed.

                      n must be 0 - 9.
                      Default value is 0 (the fastest level).

                /Zn - n is a byte-length value
                    bit0 = 1, use the slower handshaking speed with low speed 
                              device
                           0, use the normal handshaking speed with device 
                              (default)
                    bit1 = 1, suppress bi-direction mode
                         = 0, will not suppress bi-direction mode (default)
                    bit2 = 1, suppress uni-direction emulation mode
                         = 0, will not suppress uni-direction emulation mode 
                              (default)
                    bit3 = 1, suppress Enhanced Parallel Port mode
                         = 0, will not suppress Enhanced Parallel Port mode 
                              (default)
                  
                /In - Allow changing the Parallel/SCSI Converter host adapter
                      SCSI ID.  'n' stands for the new ID.

                /SM - Allow the OS2SCSI.DMD controlling the devices. 
                !SM - Disallow the OS2SCSI.DMD controlling the devices. 

                /DM - Allow the OS2DASD.DMD controlling the devices. 
                !DM - Disallow the OS2DASD.DMD controlling the devices. 


          The driver's features include the following:

                - supports PS/2 standard or PS/2 compatible (such as Winbond 
                  W83757) bi-direction printer port and Enhanced Parallel
                  Port for Intel 82360, SMC37C665, 37C666 and NS Super I/O 
                  chips.
                - drives SCSI hard disks, magneto-optical drives, and
                  removable cartridge disks, tape drives, floptical drives,
                  floppy drives, scanners, processors, CD-ROM drives and etc.
                - supports on-line disk change for removable drives.
                - compatible with OS/2 2.0 and above
                - drives up to 7 disk drives simultaneously.


        Following files are also needed for different applications, those
        files should come with your OS2 software distribution diskette. 

        For Disk application--  OS2DASD.DMD
		For CD-ROM application-- OS2SCSI.DMD, OS2CDROM.DMD, CDFS.IFS
		For ASPI application-- OS2ASPI.DMD, VASPI.SYS
		For any other SCSI application, for example, scanner-- OS2SCSI.DMD

		
IV.     Product Tested List - Not all inclusive
        ****************************************

        Most SCSI storage devices are tested even they may not be listed above.         New models are constantly added to the list.  Please consult the 
        dealers for updated information.
            
        The adapter has been tested under the following environments.
        All the above supported software's are for IBM PC AT &
        compatibles.

        SCSI Devices:

        .Disk:
                Manufacturer    Type            Model No.       Capacity
              ---------------------------------------------------------------
                ALPS            fixed disk      DRD 100S        100 MB
                CONNER          fixed disk      CP30100         121 MB
                FUJITSU         fixed disk      2611S            40 MB
                IBM             fixed disk      WDC80            80 MB
                MATSUSHITA      optical disk    LF-3090         128 MB
                MAXTOR          fixed disk      XT-8760S        638 MB  
                MAXTOR          fixed disk      LXT-213S        203 MB
                QUANTUM         fixed disk      LPS105S         105 MB
                QUANTUM         fixed disk      52S/LP           52 MB
                QUANTUM         fixed disk      525S            500 MB
                QUANTUM         fixed disk      Empire 540, 1080, 1400
                                                2100
                RICOH           optical disk    RO-5030E        280 MB
                SONY            optical disk    SMO-C301,F331   128 MB
                SONY            optical disk    SMO-C501-00     280 MB
                SEAGATE         fixed disk      ST1400          140 MB
                SYQUEST         removable disk  SQ5110           88 MB

        .Tape:
                Manufacturer    Model No.       Capacity
              -----------------------------------------------
                ARCHIVE         2150S           150 MB
                SHINWA          SDX-85          150 MB
                TEAC            MT-2ST/F        600 MB
                TEAC            MT-2ST/N        160 MB
                TEAC            MT-01N          155 MB
                TEAC            MT-01F			555 MB
                TANDBERG        TDC 3800        155 MB
                WangDAT 
                WANGTEK         5525ES          525 MB
                WANGTEK         5150ES          150 MB
                YE-Data

        .CD-ROM
                Manufacturer            Model No.   
              --------------------------------------
                Apple                   CD300,CD-SC,CD-SCPlus,Power CD
                                        Power CD II
                CD Technologies         Porta-Drive( Toshiba 3201/3301/3401 )
                CHINON                  CDS-431, CDS-435, CDS-535(PhotoCD)
                Hitachi                 1750, 3750
                Laser Magnetic:         CM212, CM214, CM231
                MATSUSHITA-KOTOBUKI     CR-501-B
                MediaVision             Reno(PhotoCD)
                NEC                     CDR-25, 35, 55 
                NEC                     CDR-72, 77, 80 
                NEC                     CDR-82,84,400,500,600, 3XP, 3XE 
                                        (PhotoCD)
                NEC                     4Xi, 4XE(PhotoCD)
				Philips                 F80
                Pioneer                 DRM-600 Smart & Friendly 522
                Plextor                 3024, 5024, 3028, 5028(PhotoCD)
                SONY                    CDU-541,CDU-561,CDU-6110,CDU-6111
                                        CDU-6211,CDU-7211 (PhotoCD)
                Texel                   DM-3010, 3020, 5010, 5020, 7120
                Toshiba                 3301, 3401, 4101, 5100 (PhotoCD)

        .DAT:
                Manufacturer    Model No.       Media
              ------------------------------------------------------------------ 
                Archive         Phyton
                RByte, ExaByte  4200, 8200, 8500 4mm, 8mm
                Hewlett Packard 35470, 35480    
				WANGTEK         6130HS          SONY DDS data Cartridge (DG-90M)

        .Scanner:
                Manufacturer    Model No.       Media
              ------------------------------------------------------------------
                Fujitsu         ScanPartner Series
                Hewlett-Packard ScanJet IIx     Note: need SJIIx.SYS

        .Operating System:
                
                MS-DOS 3.3      MS-DOS 5.00     MS-DOS 4.01
                DR-DOS 5.00     DR-DOS 6.00     MS-DOS6.20
                MS-WINDOWS 3.0  MS-WINDOWS 3.1  OS/2 2.0, 2.1, 3.0( Warp )


V.      Diagnostic utility

        Note: Run this utility through any DOS icon of the presentation
              manager only.

        A comprehesive diagnostic utility is provided as "PSDIAG.EXE".
        Type "PSDIAG.EXE" to execute the diagnostic utility.
        The diagnostic utility will scan through parallel ports supported
        in the system and display the results.  Should any problems happened
        please run the utility and write down the results before calling the
        technical support.

        Most of other diagnostic software such as MSD, QAPlus/FE, LapLink V,
        and QBench had no problem accessing hard drives with converter.



VI.     Technical tips
        **************

    Use this section as supplement to the Trouble Shooting section in the
    manual.


    a.  ASPI compatible applications tested:
        
        CorelSCSI, CorelSCSI Version 2( OS2 ), NovaBack( OS2 ).

    b.  A simple DOS based diagnostic software is included if you ever run
        into some problems.

    c.  If you had bought a Parallel/SCSI Converter Plus and got hung during
        initialization process while using the version 3.0x software.  Please
        set the /Z parameter bit 3 to 1 to disable auto-sensing for the
        Enhanced Parallel Port mode.  For example:  If the /Z1 was set 
        originally, re-set to /Z9; otherwise, set to /Z8.

    g.  If you running the Parallel/SCSI Premium( Polliwog ) on some of the
        386SL or 486SL notebooks ( like IBM Thinkpad series, AST PowerExec
        series, Compaq Ultralite series and Toshiba 4600x) and got blanked 
        out during the initialization, be sure setting the parallel port 
        address selection to 378h or 278h only.  Most of the host computer
        with EPP mode on will only support the address selection for 378h 
        and 278h.

    h.  The Parallel/SCSI Converters are certified by the laboratory of Corel
        Corp. listed as PAR/SCSI from April 1994.

    i.  NEC Triple Spin Series  If after the installation you are unable to 
        access your NEC CD-ROM, try changing the /Z parameter in your 
        CONFIG.SYS to /Z7.  If about method still does not work out, you
        need to plug in the auxiliary +5V power adapter.
      
	j.  If you are using the Compaq LTE Elite 4/75CX notebook computer,
        put the /Z4 at the end of STPRSCSI.ADD to disable the
        uni-directional byte mode.  Otherwise, the system  will hang.
        
    k.  If you are using CD-ROM ( ex. Plextor 5028 ) and having problem
        doing "DIR d:" or reading the file, make sure increasing the 
        buffer size for "VALUE" to a bigger number like 180 or add /Z1
        at the end of the device driver command line to slow done the 
        handshaking.
        
    l.  HOW TO INSTALL THE OS/2 3.0( WARP ) FROM THE Parallel/SCSI
        Converter:

		a.  Backup all of the data on the target partitions or drive you
            want to install the OS/2 3.0.
        b.  Bring up the system in DOS or OS/2 1.x, 2.x and install the
            Parallel/SCSI Converter with CD-ROM drive attached.
        c.  Insert the OS/2 3.0 CD-ROM diskette into the drive.
        d.  Type "dir" on the CD-ROM drive. You should find the 
            "CDINST.BAT" file.
        e.  Type "drive:\CDINST" and follow the instructions. 
        f.  The installation program will prompt you to prepare two blank
            diskettes and will write the operating system onto them.
        g.  When the message "Leave the installation diskette in the drive
            and prepare to re-boot" shows up, be sure to pop-out the diskette
            and find the CONFIG.SYS file in either of the two diskette( you
            may want to do this on different system ). Edit/Insert a command
            line as the following( close to the bottom of the file ):

             BASEDEV=STPRSCSI.ADD

            Save the changed CONFIG.SYS.

			 Note: The parameters should be identical to what you had
                   installed in DOS or OS/2 before.
        h.  Copy the STPRSCSI.ADD file onto the same diskette you just 
            edited as well.
        i.  Now, it's the time to put back the diskette originally in the
            floppy drive and re-boot.
        j.  The OS/2 will prompt you to do "Easy-installation" or "Advance
            Installation".  Choose what you want.  It's better to choose
            "Format the partition" option to install the new 3.0 version due
            to the fact that 3.0 is not compatible with DOS 5.x or O2/2 2.x 
            partition format very well.  System may be hung up during the 
            installation from our experiences.  Also, the system may hang
            due to not enough memory.  4Meg is reuqired by OS/2. However,
            it's not engough.  8Meg is preferred.
        h.  Follow the installation message to complete the procedure.
		i.  Now your Warp 3.0 should be up and the Parallel/SCSI Converter
            installed, too.



        Please call or Fax Shining to find out about new software
        updates & revisions for Parallel/SCSI Plus and Parallel/SCSI 
        Premium.  If you have any comments or complaints, we would love to hear
        them.
        
        
        Parallel/SCSI Converters README.OS2 v.3.6 (03/95) 

            Note:  All of the products mentioned above are registered trademark
                   of their own.

      

		Technical supports:

        SHINING Technology, Inc.
        10533 Progress Way, #C
        Cypress, CA 90630
        Tel: (714) 761-9598
        Fax: (714) 761-9624
        BBS: (714) 761-5814
        
     
[ RETURN TO DIRECTORY ]