Metropoli BBS
VIEWER: mta-3230.spc MODE: TEXT (ASCII)
  TechFax Index #0147
  3.5" MagnetoOptical SCSI  128/230 MB, summary
 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

                        ++++++++++++++++++++
                        | MTA-3230 OPTICAL |
                        ++++++++++++++++++++
                      IBM OEM STORAGE PRODUCTS



The MTA-3230 is a high performance compact 3.5" form factor, 1" high
rewritable optical disk drive.  The drive accepts MO, full O-ROM and
Partial ROM media conforming to the ISO/IEC 10090 (128 MB),
ISO/IEC DIS 13963 (230 MB), and ECMA 201 (230 MB) standards.  It is
a drive which will enable more applications to benefit from the high
capacity, low cost and increased robustness of optical storage.



APPLICATIONS
============

- Data backup, interchange and transportation
- Audio, image and video processing
- Desk top publishing
- Education/training manuals



FEATURES
========

- 230 MB or 128 MB rewritable, removable storage per cartridge
   (MO disk)
- 1" high device 3.5" floppy drive mounting holes (M3 screw)
- 5 volt, low power 8.0 W max
- 1.5 W in power saving mode
- Media data rate up to 16.70 Mb/s
- 40 ms average seek time
- Rotational speed 3600 rpm
- 243 KB read ahead buffer and cache
- Unique automatic write calibration sequence
- Accepts MO, O-ROM and PROM media
- MTBF 40,000 hours



BENEFITS
========

- Infinite capacity
- No Sway space required
- Ideal device for 3.5" floppy bay
- Ideal for portable computing applications,
   e.g., parallel port add ons
- Excellent performance for secondary storage device
- Optimized write power for varying media characteristics
   and operating environments
- Wide range of media types for varying applications
- High reliability optical drive



CONNECTORS AND SWITCH SETTINGS
==============================

SCSI bus connector and power connector are mounted on the electronic
board behind the drive.

......................................................................


  Unit Rear View
  --------------


            /                                               /
           /                                               /
          /                                               /
         /                  (top)                        /
        /                                               /
       /_______________________________________________/
       |                                               |
       |-----------------------------------------------|
       |                      ------------             |
       |                     |            |            |       /
       |                     |          SCSI Pin 1     |      /
       |                     |          | |            |     /
       |                      ----------|-             |    /
       | _______________________________|_   ________  |   /
       || . . . . . . . . . . . . . . . . | /        \ |  /
 SCSI-->| . . . . . . . . . . . . . . . . | | O O O O |<---- Power
       ||_______________________________|_|_|_______|_||/
                                        |           |
                                        |           |
                               SCSI Pin 2           Power Pin 1

               ELECTRICAL CONNECTORS REAR VIEW (top up)
                        50-pin SCSI


  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .
  Unit Rear View
  --------------
                              (bottom)

            /              _______  ____                    /
     DIP Switch S1 -----> //////// ///// <----  DIP Switch S2
          /              /______/ /___/                   /
  Remote Address       _______     _____       Remote Optional
   Connector C1 ----> ////////    ////// <----  Connector C2
       /_______________________________________________/
       ||         | | . . . . . . . . . . . . . . . . ||
 Power >| O O O O | | . . . . . . . . . . . . . . . . |<-- SCSI
       | \_______/  |_|_______________________________||
       |           ---|--------                        |
       |          |   |        |                       |
       |          | SCSI Pin 1 |                       |     /
       |          |            |                       |    /
       |           ------------                        |   /
       |                                               |  /
       |-----------------------------------------------| /
       |_______________________________________________|/




               ELECTRICAL CONNECTORS REAR VIEW (bottom up)
                        50-pin SCSI


  .....................................................................


For details of SCSI interface and power connections see electrical
interface section.



DIP SWITCH SETTINGS
===================

Two dip switches, S1 and S2, are located on bottom side of the drive
as shown the "bottom-up" view of the device, above, and in the
mechanical dimension section, below.

The values of the dip switches are read only when the drive is powered up
and the values are saved in the drive's memory for later use.  The
locations of each switch are as shown.


Dip Switch S1
-------------

  Switch
 Position Setting   Description                               Default
 -------- -------  -----------------------------------------  -------
    1       ON      Create Unit Attention of POR/SCSI Reset      ON
            OFF     Disable Unit Attention of POR/SCSI Reset
    2       ON      Check SCSI Parity                            ON
            OFF     Ignore SCSI Parity
    3       ON      Device type in Inquiry data is X "07"        ON
                     Optical Drive
            OFF     Device type in Inquiry data is X "00"
                     Fixed Disk Drive
    4       ON                                                   ON
            OFF     See table opposite
    5       ON      No spin up on POR                            OFF
            OFF     Spin up automatically on POR
    6       ON      Normal Mode                                  ON
            OFF     C2 security mode
    7       ON      Power saving default time value = X "FF"     OFF
                     (never power down)
            OFF     Power saving default timer value = X "05"
                     (5 minutes)
    8        -      Reserved for flash memory update             OFF
                     (normally must be OFF)




  Drive Switch Settings
  ---------------------

                    Options Switch Block Definition
                            DIP Switch S1
  .....................................................................
     Default positions marked by '*'

                                Switch
                             ____________
  Create Unit Attention     |            |       Disable Unit Attention
   on PRO/SCSI Reset ------ | ON  1  OFF | -----  on POR/SCSI Reset
                            | *          |
  Check SCSI Parity  ------ | ON  2  OFF | ----- Ignore SCSI Parity
                            | *          |
  Device type in Inquiry    |            |       Device type in Inquiry
   data is X'07'     ------ | ON  3  OFF | -----  data is X'00'
   Optical Drive            | *          |        Fixed Disk Drive
                            |            |
  Standard functions        |            |       Specialized functions
   for switches 1-3  ------ | ON  4  OFF | -----  for switches 1-3
   per this diagram         | *          |        (see notes below)
                            |            |
  No spin-up on POR  ------ | ON  5  OFF | ----- Auto spin-up on POR
                            |        *   |
  Normal Mode        ------ | ON  6  OFF | ----- C2 security Mode
                            | *          |
  Power saving default      |            |       Power saving default
   timer value = X'FF' ---- | ON  7  OFF | -----  timer value = X'05'
   (never power down)       |        *   |        (5 minutes)
                            |            |
  Reserved for flash        |            |
   memory update      ----- | ON  8  OFF | ----- Normal operation
   (normally must be OFF)   |        *   |
                            |____________|


  .....................................................................


                    Address Switch Block Definition
                            DIP Switch S2
  .....................................................................
     Default positions marked by '*'

                                Switch
                             ____________
                            |            |
  Address Bit 0 Enable ---- | ON  1  OFF | ----- Address Bit 0 Disable
                            |        *   |
  Address Bit 1 Enable ---- | ON  1  OFF | ----- Address Bit 1 Disable
                            |        *   |
  Address Bit 2 Enable ---- | ON  1  OFF | ----- Address Bit 2 Disable
                            |        *   |
  Disable SCSI              |            |       Enable SCSI
   Active Terminator   ---- | ON  1  OFF | -----  Active Terminator
                            |        *   |
                            |____________|

  .....................................................................



Dip Switch S1 Position 1 through 3 have specialized configuration
meaning when used while Dip Switch S1 Position 4 is OFF.

  Customization Switch Setting for Dip Switch S1 (with Position 4 OFF)
  --------------------------------------------------------------------
  Position 1  Position 2  Position 3       Meaning
  - - - - -   - - - - -   - - - - -        - - - - - - - - - - - - - - -
     ON          ON          OFF           Device type "00" and special
                                           mode page data (page 1, 2, 3, 4)
                                           support

  All other switch combinations reserved.


Customization Switch
--------------------
Dip Switch S1 Position 1 through 4 are intended for special customized
configuration for each application.


Automatic Spin Up Switch
------------------------
Dip Switch S1 Position 5 is for selecting that the spindle motor turns on
or off automatically at power on reset (POR) time with the cartridge in
loaded position.


C2 Security Mode Switch
-----------------------
Dip Switch S1 Position 6 is for selecting the operation mode of loading
and unloading the cartridge (normal or in C2 security mode).


Power Saving Default Timer Value
--------------------------------
Dip Switch S1 Position 7 is for selecting never power down or power down
the drive after 5 minutes.


Reserved Switch
---------------
Dip Switch S1 Position 8 is reserved.  These must be set off when the
drive is in normal operation mode.  Under no circumstances switch this
switch ON when +12 VDC is applied except for maintenance purposes.



Dip Switch S2
-------------
  Switch
 Position  Setting   Description                             Default
 --------  -------  --------------------------------------  ---------
    1        ON      Address Bit 0 Enable
             OFF     Address Bit 0 Disable                     OFF
    2        ON      Address Bit 1 Enable
             OFF     Address Bit 1 Disable                     OFF
    3        ON      Address Bit 2 Enable
             OFF     Address Bit 2 Disable                     OFF
    4        ON      Disable SCSI Active Terminator
             OFF     Enable SCSI Active Terminator             OFF


Drive Address Dip Switch Setting
--------------------------------
   SCSI Drive           Dip Switch S2
    Address         3          2          1       Default
   ----------      ---        ---        ---      --------
       0           OFF        OFF        OFF      Selected
       1           OFF        OFF        ON
       2           OFF        ON         OFF
       3           OFF        ON         ON
       4           ON         OFF        OFF
       5           ON         OFF        ON
       6           ON         ON         OFF
       7           ON         ON         ON


SCSI ID Switch
--------------
Dip Switch S2 Position 1, 2 and 3 are for setting the drive address
as shown.  These are used to respond to selection or to place the
device ID on the bus during reconnection.

Note:  Dip Switch S2 Positions 1, 2, and 3 must be set to "OFF" state
when remote address connector is used as described in remote drive
address connector setting.


SCSI Terminator Switch
----------------------
Dip Switch S2 Position 4 is for selecting that the SCSI active
terminator is enable or disable.  "Enable" means that the on board
active terminators are connected.


Remote Drive Address Connector Setting
--------------------------------------
Drive address switch can be set remotely through the host system using
Pin 2, 3 and 4 of remote drive address connector (see figure 2).  This
address setting is enabled when the Dip Switch S2 Position 1, 2 and 3
are at "OFF" position (wired 0Red with Dip Switch S2 Position 1, 2 and
3).

The remote drive address connector is designed to mate with Molex
PN 51021-0600 utilizing Molex pin PN 50058-8000 (AWG #28-32) or
50079-8000 (AWG #26-28).  Equivalents of these part numbers are
permissible.

Pin 6 is for configuration control test use.  This pin should be
open for normal operation.

  Pin   Function
  ---   ----------------------------------------------
   1    Ground
   2    Drive address bit 0 (LSB)
   3    Drive address bit 1
   4    Drive address bit 2 (MSB)
   5    Power Down Mode Indication (output)
   6    Configuration Control (reserved must be open)


Remote Optional Connector Setting
---------------------------------
Drive configuration can be changed remotely using Pin 1 through Pin 4
of the Remote Optional Connector.  These settings are enabled when Dip
Switch S1 Position 1, 3 and 4, and Dip Switch S2 Position 4 are in the
"OFF" position (wired ORed with these Dip Switches).

The Remote Optional Connector is designed to mate with Molex
PN 51021-0400 utilizing Molex PN 50058-8000 (AWG #28-32) or 50079-8000
(AWG #26-28).  Equivalents are permissible

  Pin   Function
  ---   -------------------------------------------
   1    Wired ORed with Dip Switch S1 Position 1
   2    Wired ORed with Dip Switch S1 Position 3
   3    Wired ORed with Dip Switch S1 Position 4
   4    Wired ORed with Dip Switch S2 Position 4



ELECTRICAL INTERFACE SPECIFICATIONS
===================================

SCSI Bus Cable
--------------
External cables must not exceed 6 meters in length.  The cable should
be a 50 conductor flat cable or a 25 signal twisted pair cable.  The
drive conforms to the max stub length of 0.1 meter for single ended
options as specified in the ANSCI SCSI standard (X3.131-1986).


Power Connectors
----------------
The DC power connector is designed to mate with AMP PN 1-480424-0 using
AMP pins PN 350078-4 (strip) or 61173-4 (loose piece).  Equivalents of
these part numbers are permissible.  Pin numbering and assignments are
shown in Figure 3 as viewed from the direction of cable insertion.

  ........................................................................

                          POWER CONNECTIONS


                       Pin #  4   3   2   1
                         _______________________
                         |  _________________  |
                         | /                 \ |
                         | | +5V GND GND +12V| |
                         | |  O   O   O   O  | |
                         | |_________________| |
                         |_____________________|



           Power Connector Pin Assignments

  Pin   Voltage
  ---   -----------------------------------------------------------------
   1    Reserved (+12 VDC can be connected for flash memory update)
   2    Reserved (Ground Return can be connected for flash memory update)
   3    Ground Return
   4    +5 VDC

  ........................................................................


SCSI Signal Connector
---------------------
The SCSI signal connector is a 50-pin connector.  Molex PN 70248 or
equivalent, which meets ANSI/SCSI specifications.


SCSI Bus Terminators
--------------------
Active termination for the last device on the SCSI cable is
accomplished by setting Dip Switch S2 Position 4.



DC POWER REQUIREMENT LIMITS
===========================

Power supplied to the drive must conform to the following limits:

  Nominal                      +5 Volts (1)         Total Power (2)
  ------------------------     ------------         ---------------
  Tolerance                       +/- 5%                 -
    (include ripple)
  Ripple (0 to 20 MHz)         100 mV pp                 -
  Supply current
    (power saving mode) (3)       0.3A                  1.5W
    (max at idle) (4)             1.00A                 5.0W
    (max at operation) (5)        1.6A                  8.0W

Note:
1.  Exclude peak current less than 1 msec duration.
2.  Assume that SCSI terminator power line in the host side is connected.
    The actual power consumption varies depending on your SCSI configuration
    and usage.
3.  Power saving mode is the lowest power consumption mode which is entered
    when no activities including SCSI have been done during the time
    specified by SCSI MODE Command of power saving timer control.
    "Mode Page 21" to set power saving timer control.
4.  "Idle" means waiting host command in track following.  Exclude the
    peak current at 1 track kick back.
5.  "Max at operation" occurs during write or erase operation.



VIBRATION AND SHOCK
===================

Operating Vibration
-------------------
The drive will withstand (with no permanent error) vibration levels of
0.27 G RMS from 5 to 500 Hz in all three directions.


Operating Shock
---------------
The drive will withstand (with no permanent error) shock levels of 5 G
half sine wave shock pulse of 11 mS duration.


Non-Operating Shock
-------------------
No damager occurs as long as the unpackaged drive is not subjected to
35 Gs, 11 mS (approximate square pulse) duration.



OPERATING ENVIRONMENT
=====================

The drive operates within its performance limits when the following
environment is maintained.  Product life calculations are based on the
nominal environment for a typical application.

Humidity:
---------
Operating          8% to 80% non-condensing
Storage            5% to 95% non-condensing
Shipping           5% to 95% non-condensing

Wet Bulb Temperature:
---------------------
Operating          81 degrees F (27 degrees C) maximum
Shipping/Storage   84 degrees F (29 degrees C) maximum

Elevation:
----------
Operating          0 to 6932 feet (0 to 2133 meters)

Temperature:
------------
Operating ambient  50 to 104 degrees F (10 to 40 degrees C)
Shipping           -40 to 140 degrees F (-40 to 50 degrees C)
Storage            32 to 140 degrees F (0 to 60 degrees C)


Air Flow Requirement:
---------------------
Recommended air flow direction is from rear to front of the drive.


Air Flow Volume:
----------------
Equal or greater than 0.030 cubic meter per minute (1.06 CFM) through
the drive while a media is loaded in the drive.


Air Filtration:
---------------
It is strongly recommended that drive enclosures are filtered so as to
minimize drive contamination.  The air flow must be sufficient to take
account of the filter.  The filter should be changed periodically to
maintain sufficient air flow.


Temperature:
------------
Less than 45 degrees C.



COMMAND SELECT OPTIONS
======================

The following Commands are supported by the drive:

Group 0                      Group 1
Commands            (Hex)    Commands            (Hex)
------------------  -----    ------------------  -----
Test Unit Ready     (00)     Read Capacity       (25)
Re-Zero Unit        (01)     Read Extended       (28)
Request Sense       (03)     Write Extended      (2A)
Format Unit         (04)     Seek Extended       (2B)
Reassign Blocks     (07)     Erase               (2C)
Read                (08)     Write Verify        (2E)
Write               (0A)     Verify              (2F)
Seek                (0B)     Read Defect Data    (37)
Inquiry             (12)     Write Buffer        (3B)
Mode Select         (15)     Read Buffer         (3C)
Reserve             (16)     Read Data Long      (3E)
Release             (17)     Write Data Long     (3F)
Mode Sense          (1A)
Start/Stop Unit     (1B)
Send Diagnostics    (1D)
Prevent/Allow
Media Removal       (1E)


Group 5                      Group 6
Commands            (Hex)    Commands            (Hex)
------------------  -----    ----------------- -------
Read Extended       (A8)     Reserved          (C0-C6,
Write Extended      (AA)                        D0-D2)
Erase Extended      (AC)     Restore Unit         (D8)
Write Verify
Extended            (AE)
Verify Extended     (AF)

Note:  The drive defaults to 3 pass WRITE (ERASE-WRITE-VERIFY)
unless 1WV = 1 is set on Mode Page 0 (to turn off VERIFY).



MECHANICAL DATA
===============

   Dimensions (with bezel)
   -------------------------------
   Height       25.4 mm +/- 0.4 mm
   Width       101.6 mm +/- 0.4 mm
   Depth       172.9 mm +/- 0.4 mm
   Weight      481 grams


Mounting Orientation
--------------------
The mounting orientation of the drive in the host system shall be
horizontal with eject button under cartridge opening or vertical with
eject button to the right of the cartridge opening.  Upside down or on
end is not permitted.  Recommended vertical mounting is with eject button
to the right of the cartridge opening.  The drive shall operate within
specification when tilted horizontally or vertically +/- 5 degrees in
horizontal drive mounting.  In addition it will operate within
specifications when tilted +/- 10 degrees in vertical drive mounting.




        IBM MTA 3230 Optical Disk Drive Mechanical dimensions
        =====================================================

  .......................................................................
   NOTE:  Maximum screw penetration of 3 mm must not be exceeded.

                                  SIDE VIEW
                                  =========
       REAR                                             Bezel
                                                          v
  SCSI               ---------------------------------------  - - - - - -
  and               |                                   |   |          :
  Power             |         (4x) M3                   |   |          :
  Connectors        |               |                   |   |   G      F
   ----------->  ---|               v                   |   |   :      :
                |   |             - O - - - - - - O - - | - | - - -    :
                :-------------------:-------------:---------: - - - - - -
                :   :               :             :     :   :   :
                :   :               :- - - A - - -:- B -:-C-:
                :   :- - - - - D - - - - - - - - - - - -:
                :- - - - - - - - - - - - - E - - - - - -:

        A =  60.00         mm   front mount hole to center mount hole
        B =  21.00         mm   DE front to front mount hole CL
        C =   4.00         mm   bezel thickness
        D = 150.00 +/- 0.4 mm   DE length
        E = 168.90 +/- 0.4 mm   DE + connector length
        F =  25.40 +/- 0.4 mm   DE height (1" models)
        G =   5.00         mm   mount hole CL above bottom DE surface
        H =   2.00         mm   minimum required clearance under DE

   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
                                BOTTOM VIEW
                                ===========             Bezel
                                                          v
            - - - ---------------------------------------|---|
   Power     :   |   |       - O - - - - - - - - O - - - | - | - - - -
   Connector :   |   |  _<--C1 Remote Address Connector  |   |      :
             :   |---| | | _                             |   |      :
 REAR        :   |   | |_||_|<--S1 DIP Switch            |   |      :
             A   |---|  _  _                             |   |      F
             :   |   | |_||_|<--S2 DIP Switch    (4x) M3 |   |      :
   SCSI      :   |   |  |                        |       |   |  E   :
   Connector :   |   |  C2 Remote Option Conn.   v       |   |  :   :
             :   |   |       - O - - - - - - - - O - - - | - | - - - -
            - - - -------------:-----------------:-------|---| - -
                               :                 :              :        -
                               :- - B - - - - - -:- -C- -:   :
                                                         :   :
                                                        -:-G-:-

        A = 101.60 +/- 0.4 mm  DE width
        B =  70            mm  distance between mount hole CLs
        C =  21            mm  DE front to front mount hole CL
        E =   3.8          mm  DE side to mount hole CL
        F =  94            mm  distance between mount hole CLs
        G =   4            mm  bezel thickness

   Overall Dimensions
  .......................................................................

Note:  Maximum screw lengths must not be exceeded.



REWRITABLE DATA ORGANIZATION
============================

Optical Disk Format for 128 MB and 230 MB Disk
----------------------------------------------
The drive has the capability of reading and writing the data on the media
which conforms with ISO/IEC 10090 and ECMA 201 (230 MB)

  Disk Format of ISO/IEC 10090
  ----------------------------
  User Area                          24.00 mm to 40.00 mm (Radius)
  Track Format
    User Data/Spare Tracks           10,000 (include 6 tracks of Disk
                                      Definition tracks)
    Tracks                           Spiral (CAV)
    Tracking Provisions              Continuous Composite
    Direction of Rotation            CCW from Laser Side
    Track Pitch                      1.6 micron
    Recording Location               Onland
    Control Track Location           Inner Diameter and Outer Diameter
    Track 0 Location                 Inner Diameter
  Sector Format
    User Bytes/Sector                512
    Sectors/Track                    25
  ECC                                Reed-Solomon LDC
  Modulation Method                  RLLC (2,7) PPM Encoding


  Disk Format of ECMA 201 (230 MB)
  --------------------------------
  User Area                          24.00 mm to 40.00 mm (Radius)
  Track Format
    User Data/Spare Tracks           17,940 (include 6 Logical
    Buffer Track (Logical)           Tracks reserved for Disk
                                      Definition tracks)
    Data Zone Tracks                 11,500
    (Physical)
    Tracks                           Spiral (CAV)
    Tracking Provision               Continuous Composite
    Direction of Rotation            CCW for Laser Side
    Track Pitch                      1.39 micron
    Recording Location               Onland
    Control Track Location           Inner Diameter and Outer Diameter
    Track 0 Location                 Inner Diameter
  Sector Format
    User Bytes/Sector                512
    Sectors/Track                    25
  ECC                                Reed-Solomon LDC
  Modulation Method                  RLLC (2,7) PPM Encoding

Refer to ISO/IEC 10090 and ECMA 210 (230 MB)
"Information Technology - 90 mm optical disk cartridges, rewritable and
read only, for data interchange."


Media Characteristics
---------------------
  Disk Diameter                   86.0 mm
  Disk Substrate                  ISO standard
  Data Capacity
    MO (1)                        127 M Bytes (Formatted)
    MO (2)                        229 M Bytes (Formatted)
    Full 0ROM (1)                 122 M Bytes (Formatted)
    Full 0ROM (2)                 220 M Bytes (Formatted)
    Partial ROM (1)               127 M Bytes (Max) (Formatted)
    Partial ROM (2)               228 Bytes (Max) Formatted)
  Recording Surface               Singleside
  Density
    Tracks per mm (1)             625
    Tracks per mm (2)              719
    Bits per mm (1)               961
    Bits per mm (2)               1154
  User Zone                       24.00 mm to 40 mm (Radius)

Note:
1.  This drive accepts the media specified in ISO/IEC10090
2.  This drive accepts the media specified in ECMA 201 (230 MB)







AMP is a trademark of AMP Incorporated.
Molex is a trademark of Molex Incorporated
DATA MATE is a trademark of AMP Incorporated
Western Digital is a trademark of the Western Digital Corporation.
NEXT is a trademark of NEXT Corporation.

This data sheet is not a substitute for the full product specification,
which should be used when detailed information is required.

Product Description data represents IBM's design objectives and is
provided for comparative purposes; actual results may vary based on
a variety of factors.  This product data does not constitute a
warranty.  Questions regarding IBM's warranty terms or methodology used
to drive this data should be referred to your IBM OEM representative.
Data subject to change without notice.

WARNING:  This disk drive can be damaged by Electro-Static Discharge,
please follow recommended ESD procedures before unpacking or handling
the drive.  Ask you Dealer for details if you need assistance.


This file was last updated on 01/12/95 by jjm
[ RETURN TO DIRECTORY ]