Metropoli BBS
VIEWER: wds-l.spc MODE: TEXT (CP437)
Updated June 18, 1996
________________________________________________________________________

Models WDS L80 & L160                                IBM Hard Disk Drive
________________________________________________________________________
http:\\www.storage.ibm.com\storage\techsup\hddtech\hddtech.htm



FEATURES
========
- 85/171 MB formatted capacity (512 bytes/sector)
- Industry standard interface:  ANSI/SCSI-2
- Integrated controller
- Logical block addressing (LBA)
- Implied seeks
- SCSI Disconnect and reconnect capability
- Interface Odd parity supported
- 1:1 interleave
- 1,7 Run-Length Limited (RLL) encoding
- Constant Density "Bit Recording"
- SCSI data transfer rate:  up to 5 MB/S (synchronous)
- 32 KB Segmented Look Ahead Buffer
- Command Queuing
- Auto Reassign Block
- Self-diagnostics on power up
- Automatic retry and data corrections on read errors
- No preventative maintenance required
- Media data transfer rate:  13.3 Mbits/Sec
- Closed loop actuator servo (embedded sector servo)
- Rotary voice coil actuator
- Automatic actuator lock
- Dedicated head landing zone
- Average seek time = 16mS/18.5mS
- All axis (6 directions) mounting permitted
- MTBF 150,000 hours

PERFORMANCE
===========
                            WDA-L80     WDS-L160
                            -------     --------
Media Read/Write
data transfer--rate in
Mbits/Sec                     13.3         13.3
Seek times (in mS, averaged & inc settle)
                             Read         Write
  Track to Track              4.0           5.0
  Average length             16.0          18.5
  Full length                30.0          32.5

Spindle Speed                3600RPM
  Average Latency            8.33mS
Power ON to Drive
Ready                        8.7 Sec (ave), 10.7 Sec (max)
Power OFF to Spindle
Stop                         6 Sec (ave), 12 Sec (max)

ELECTRICAL CONNECTOR LOCATIONS
==============================


           ┌──────────────────────────────────────────┐
           │                                          │
           │ ┌───────────────────────────┬──────────┐ │
           │ │ ......................... │          │ │
           │ │ ......................... │ O O O O  │ │
           └─┴─────────────────────────┼─┴───────┼──┴─┘
                                       │         │
                                      SCSI     Power
                                      Pin 1    Pin 1


There is a choice of 2 power connections to this drive.  One DC
power connector is designed to mate with AMP part 1-480424 (using AMP
pins P/N 350078-4).  The other (3 pin) DC power connector is designed
to mate with MOLEX 5480-03 (using MOLEX pins 5479).  Equivalent
connectors may be used.  Pin assignments are show below, as viewed
from the end of the drive.


       Pin #   4 3  2  1                1   2   3
           ╔════════════════╗        ┌────────────┐
           ║                ║        │ ┌┐  ┌┐  ┌┐ │
           ║   O  O  O  O   ║        │ ││  ││  ││ │
           ║                ║        │ └┘  └┘  └┘ │
           ╚════════════════╝        └────────────┘
             +5V GNDGND +12V          +5V +12V GND





TERMINATORS
===========
'T-RES is active terminator MYOGJ 'J' is terminator jumper switch.
SCSI Bus terminator jumper switch pin assignment is:


              SCSI I/F Connector
            ┌──────────────────┬─────┐
            ├──────────────────┴─────┤
   T-RES────┼──┌───────┐             │
            │  └──┬─┬──┘             │
      J ────┼─────│ │                │
            │     └─┘                │
            │                        │
            │                        │
            │                        │
            │                        │
            │                        │
            │                        │
            │                        │    ┌──────┐
            │                        │    │┌────┐│
            │                        │    ││0  0││  3: Jumper switch
            │                        │    │└────┘│     Default "ON"
            │                        │    │ 0  0 │  2: NC
            │                        │    │      │
            │                        │    │ 0  0 │  1: NC
            └────────────────────────┘    └──────┘
              Card Module Side View      I/F Connector Side

Figure 1 SCSI Bus Terminators Jumper Location and Pin Assignment




OPTION BLOCK
============


           ┌────────────────────────────────────────┐
           │                                        │
           │                            ┌───────┐   │
           │                            │.......│   │
           │                            │... ...│   │
           └────────────────────────────┴──────┼┴───┘
                                               │
                                          Options Block
                                             Pin 1



Jumper Settings
---------------
Jumpers may be fitted to select the following options:

                                       Pin Numbers
Auto spin-up control                      9-10
Device SCSI-ID selection              1-2, 3-4, 5-6
(see table for details)
LED drive lines                          13-14

A Bit is selected when a Jumper is in place

                             Auto
           Address Jumpers  Spinup   LED
              0   1   2     Enable  Anode(+)
           ┌──┼───┼───┼───────┼───────┼──┐
           │ LSB     MSB      │       │  │
           │ ┌─┐                         │
           │ │O│  O   O       O   O   O  │
           │ │O│  O   O   O   O   O   O  │
           │ └┬┘  │   │   │   │       │  │
           └──┼───┼───┼───┼───┼───────┼──┘
              ├───┴───┴─┬─┴───┘    LED Cathode(-)
  Example shows        GND Pins
  Address 1 selected



Option Block-SCSIID selection


                Bit
              0  1  2
           ┌───────────────────────┐         ┌───────────────────────┐
           │                       │         │       ┌─┐             │
           │  O  O  O     O  O  O  │         │  O  O │O│    O  O  O  │
           │  O  O  O  O  O  O  O  │ = 0     │  O  O │O│ O  O  O  O  │ = 4
           │                       │         │       └─┘             │
           └───────────────────────┘         └───────────────────────┘

           ┌───────────────────────┐         ┌───────────────────────┐
           │ ┌─┐                   │         │ ┌─┐   ┌─┐             │
           │ │O│ O  O     O  O  O  │         │ │O│ O │O│    O  O  O  │
           │ │O│ O  O  O  O  O  O  │ = 1     │ │O│ O │O│ O  O  O  O  │ = 5
           │ └─┘                   │         │ └─┘   └─┘             │
           └───────────────────────┘         └───────────────────────┘

           ┌───────────────────────┐         ┌───────────────────────┐
           │    ┌─┐                │         │    ┌─┐┌─┐             │
           │  O │O│ O     O  O  O  │         │  O │O││O│    O  O  O  │
           │  O │O│ O  O  O  O  O  │ = 2     │  O │O││O│ O  O  O  O  │ = 6
           │    └─┘                │         │    └─┘└─┘             │
           └───────────────────────┘         └───────────────────────┘

           ┌───────────────────────┐         ┌───────────────────────┐
           │ ┌─┐┌─┐                │         │ ┌─┐┌─┐┌─┐             │
           │ │O││O│ O     O  O  O  │         │ │O││O││O│    O  O  O  │
           │ │O││O│ O  O  O  O  O  │ = 3     │ │O││O││O│ O  O  O  O  │ = 7
           │ └─┘└─┘                │         │ └─┘└─┘└─┘             │
           └───────────────────────┘         └───────────────────────┘


Pins 8, 11, and 12 are reserved




SHIPPING DEFAULT SETTINGS
=========================
The DEVICE ID is set at 6 (ie, jumpers on pins 3-4 and 5-6).

AUTO SPIN-UP is enabled (ie, jumpers on pins 9-10).

NOTE:  LED connections, pin 13 can source up to 18mA.  Pin
14 can sink up to 100mA.

AUTO SPIN-UP, pin 9.  If a jumper is fitted, the drive will spin-up
automatically after power on reset completes.

If a jumper is not fitted, the drive will not spin-up unless the
host system issues a "start command" to the drive.




OPERATING ENVIRONMENT
=====================

Humidity:
---------
Operating               8% to 90% noncondensing
Relative

Nonoperating            5% to 95% noncondensing
Relative

Wet Bulb Temperature:
---------------------
Maximum Wet Bulb:
Operating               29.4 degrees C noncondensing
Nonoperating            35 degrees C noncondensing

Elevation:
----------
Operating Altitude      -150 to 3000m
Ship/Storage            -150 to 12000m
Altitude

Temperature:
------------
Operating               5 to 55 degrees C
Storage                 -40 to 65 degrees C
Shipping                -40 to 65 degrees C
Temperature
Gradient                15 degrees C per hour (maximum)
(Operating, Storage, & Shipping)

Air Cooling Requirement
-----------------------
The host system must provide sufficient air flow across the drive to
maintain the temperature at less than 60 degrees C (measured at the
center of the drives' top cover).

Operating Vibration
-------------------
Due to the complexity of this subject we recommend that users contact
the Distributor to discuss how to perform the necessary measurements
if they believe this to be an area which requires evaluation.

Nonoperating Vibration
----------------------
The Drive will withstand the following continuous vibration levels with
no degradation in performance:  2 - 200Hz @ 0.5G peak acceleration (for
a resonance search).
Resonance points:  1.5G zero to peak acceleration (for 15 mins).

Operating Shock
---------------
The Drive will withstand (with no permanent damage or loss of data) a
10G half-sine wave shock pulse of 11mS duration.

Nonoperating Shock
------------------
The Drive will withstand (with no permanent damage or loss of data) a
75G half-sine wave shock pulse of 11mS duration.

SIGNAL DEFINITION
=================
The pin assignments of interface signals are listed as follows

  PIN      Signal              PIN       Signal
   01       GND                 02        DB0
   03       GND                 04        DB1
   05       GND                 06        DB2
   07       GND                 08        DB3
   09       GND                 10        DB4
   11       GND                 12        DB5
   13       GND                 14        DB6
   15       GND                 16        DB7
   17       GND                 18        PARITY
   19       GND                 20        GND
   21       GND                 22        GND
   23       GND                 24        GND
   25       OPEN                26        TERMPWR
   27       GND                 28        GND
   29       GND                 30        GND
   31       GND                 32        -ATN
   33       GND                 34        GND
   35       GND                 36        -BSY
   37       GND                 38        -ACK
   39       GND                 40        -RST
   41       GND                 42        -MSG
   43       GND                 44        -SEL
   45       GND                 46        -C/D
   47       GND                 48        -REQ
   49       GND                 50        -I/O


DC POWER REQUIREMENTS
=====================
Nominal Supply
Voltages                      +5 Volts        +12 Volts
Maximum Ripple
(0-10 MHz)                    100mV p-p       200Mv p-p
Voltage Supply Tolerance      +/-5%           +10%/-8%
Power Supply Current
(Amps)                        +5 Volts        +12 Volts
  *Start peak                 0.5             0.93
  *Idle average               0.3             0.12 (0.13/
                                              WDS-L160)
  *Random R/W                 0.3             0.14 (0.15/
                                              WDS-L160)

Random R/W = 40% random seek +40% read/write (1 write in 10 reads)
+ 20% idle.

NOTE:  There is no requirement to limit the +5V current as the drive
incorporates its own protection, the system must limit the +12V current
supply to the drive to less than 20A.

DATA ORGANIZATION
=================
Physical Layout
---------------
                                  WDS-L80       WDS-L160
Bytes per Sector                  512           512
Total Data Sectors                85,658,112    171,316,224
Sectors per Track                 44            44
Sectors per Cylinder              87            174
Spare Sectors per Cylinder        1             2
Number of data Heads              2             4
Number of Disks                   1             2
Logical Layout                    85 MB         170 MB
Max Relative Block                167,301       334,601
Addresses
Total Data Bytes                  85,658,112    171,315,712

ELECTROMAGNETIC COMPATIBILITY
=============================
The Drive meets the following EMC requirements when installed in the
user system and exercised with a random accessing routine at maximum
data rate:

United States Federal Communication Commission (FCC) Rules and
Regulations Part 15, Subject J--Computer Devices "Class B Limits."

European Economic Community (EEC) directive #76/889 related to the
control of radio frequency interference and the Verband Deutscher
Elektrotechniker (VDE) requirements of German (GOP).

MECHANICAL DATA
===============
Dimensions
  Height                                19.9 +/- 0.4mm
  Width                                101.6 +/- 0.4mm
  Depth                                146.0 +/- 0.6mm
  Weight                               410g maximum
Mounting Orientation
  The Drive can be mounted in any axis
  (6 directions).


           |...................146 +/- 0.6.................|
           ┌───────────────────────────────────────────────┐───
          ┌┴┐                                              │ .
          │ │                                              │ .
          │ │                                              │ .
          │ │                                              │ .
          │ │                                              │ .
          │ │                                              │ .
          │ │                                              │ .
          │ │                                              │101.6 +/- 0.4
          │ │                                              │ .
          │ │                                              │ .
          │ │(4X)M4                                        │ .
          │ │  │                                           │ .
          │ │  │                                           │ .
          └┬┘  o                o
           └───────────────────────────────────────────────┘───
               |..41.6 +/- 0.2..|.......60 +/- 0.1.........|




                         |----44.4 +/-0.1----|60.3 +/-0.2|
           ┌──────────────────────────────────────────────┐
          ┌┴┐            o                   o            │
          │ │                                             │
          │ │                                             │   Rear
 Front    │ │                                             │
          │ │                                             │
          │ │                                             │
          │ │                                             │
          │ │                                           o │
          │ │                                             │
          │ │                                             │
          │ │                                             │
          │ │                                             │
          │ │                                             │
          └┬┘            o                    o           │
           └─────────────┼────────────────────────────────┘
                         └─(4X) M4


NOTE:  Maximum screw lengths must not be exceeded.

MODE SELECT OPTIONS
===================
The following Mode Sense Pages are supported:

Page 1--Read/Write Error Recovery Parameters
  TB (Transfer Block)
  PER (Post Error)
  DTE (Disable Transfer on Error)
  DCR (Disable Correction Bit)
  Read Retry Count
  Correction Span
  Write Retry Count

Page 2--Disconnect/Reconnect Parameters
  Read Buffer Full Ratio
  Write Empty Buffer Ratio

Page 3--Format Device Parameters

Page 4--Rigid Disk Drive Geometry Parameters

Page 8--Caching Parameters
  RCD (Read Cache Disable)

Page A--Control Mode Page
  Queue Algorithm Modifier
  QErr (Queue Error Management)
  DQue (Disable Queuing)

PACKAGING:  The drive must be protected against Electro-Static
Discharge especially when being handled.  The safest way to avoid
damage is to put the drive in an anti-static bag before ESD wrist
straps, etc, are removed.

Drives should only be shipped in approved containers, sever damage can
be caused to the drive if the packaging does not adequately protect
against the shock levels induced when a box is dropped.  Consult the
dealer if you do not have an approved shipping container.

-------------------------------------------------------------------------
AMP is a trademark of AMP Incorporated.  Molex is a trademark of Molex
Incorporated.  DATA MATE is a trademark of AMP Incorporated.  Western
Digital is a trademark of the Western Digital Corporation.  NEXT is
a trademark of NEXT Corporation.

IBM OEM Europe  PO Box 6  Langstone Road  Havant  Hampshire  PO9 1SA
United Kingdom  Telephone (44) 705 486363

This data sheet is not a substitute for the full product specification
which should be used when detailed information is required.

Product Description data represents IBM's design objectives and is provided
for comparative purposes; actual results may vary based on a variety of
factors.  This product data does not constitute a warrant.  Questions
regarding IBM's warrant terms or methodology used to derive this data
should be referred to your IBM OEM representative.  Data subject to change
without notice.

[ RETURN TO DIRECTORY ]