Metropoli BBS
VIEWER: h3-sx.spc MODE: TEXT (ASCII)
Updated June 18, 1996
________________________________________________________________________

Models H3133-S2, H3171-S2, H3256-S3, H3342-S4        IBM Hard Disk Drive
________________________________________________________________________
http:\\www.storage.ibm.com\storage\techsup\hddtech\hddtech.htm



The default shipping condition device ID address is #0, auto spin up
option is enabled, and No LED port load is present.



           1-2  3-4  5-6      9-10 11-12 13-14
           ____________________________________

           OFF  OFF  OFF       OFF   ON    OFF
            |    |    |         |     |     |
            |    |    |         |     |     |
            |    |    |         |     |     |____ No LED load
            |    |    |         |     |__________ SCSI Terminator ON
            |    |    |         |________________ Auto Spin up enabled
            |    |    |
            |    |    |_________________________
            |    |______________________________|_Device ID = #0
            |___________________________________|




                                     Auto   Term
               Device ID           Spin up   ON     LED
           _________________         _____  _____  _____
           |               |         |   |  |   |  |   |
            ___   ___   ___           ___    ___    ___
           |   | |   | |   |         |   |  |   |  |   |
           | 1 | | 3 | | 5 |         | 9 |  | X |  | 13|
           |___| |___| |___|         |___|  |___|  |___|
                                              |
            ___   ___   ___    ___    ___    _|__   ___
           |   | |   | |   |  |   |  |   |  |   |  |   |
           | 2 | | 4 | | 6 |  | 8 |  | 10|  | X |  | 14|
           |___| |___| |___|  |___|  |___|  |___|  |___|

      /--------------------------------------------------------/
                            Raw Card
      /--------------------------------------------------------/
                         Disk Enclosure

      Note:  X----X means shunt jumper is installed (ON).

Figure 7.  SCSI Jumper Default Condition
----------------------------------------------------------------------

Term ON - Enables the on drive active termination

Auto Spin up - Enables drive to automatically spin up when power
               is applied.

SCSI  ID
--------
OFF   OFF   OFF = 0
ON    OFF   OFF = 1
OFF   ON    OFF = 2
ON    ON    OFF = 3
OFF   OFF   ON  = 4
ON    OFF   ON  = 5
OFF   ON    ON  = 6
ON    ON    ON  = 7


Mechanical Outline
------------------
The card with disk enclosure mechanical outline is as follows:


            ______________________________________________
            |    _____                                     |
           _|_       _|_                                   |
  SCSI I/F | |       | | <---JP13-14                       |
 Connector | |       | |              Back Side of Drive   |
           | |       |_| <---JP1-2                         |
           | |        |________________________________    |
           | |                                        |    |
           | |                                        |    |
           | |                                        |    |
           | |                                        |    |
           | |                                        |    |
           | |    Logic Card                          |    |
           | |                                        |    |
           | |                                        |    |
           |_| _______________________________________|    |
            |______________________________________________|

Figure 8.  Mechanical Outline

[ RETURN TO DIRECTORY ]