CONTROLLER TESTS. REV 1.
/--------- CONTROLLERS.-------------\
=========================================================
| Make |Futr. Dom.| Adaptec | Adaptec | OMTI |
| Model | TMC 860 |AHA 1542B |AHA 1542B | 822 |
| Revision | 204 | 3.08/H | 3.08/H | B |
-------==========================================================
| | Make | Fujitsu | Fujitsu | Fujitsu | Fujitsu |
|DRIVE | Model | M2614SA | M2612SA | M2613SA | M2612SA |
| | Revision | C6 | A7 | C6 | A7 |
-------+-----------+----------+----------+----------+------------
| | Make | Dell 286 | Dell 286 | Compaq | Dell 286 |
|SYSTEM| Model | 200 | 200 | 286 | 200 |
| | Clock rate| 12 Mhz. | 12Mhz. | 8 Mhz. | 12/6.2 Mhz.|
-------+-----------+----------+----------+----------+------------
| S/W | Type | DOS | DOS | DOS | DOS |
| | Version | 3.3 | 3.3 | 3.3 | 3.3 |
-----------------------------------------------------------------
Notes | | | | 1 |
=================================================================
ON BOARD FIRMWARE | 6.0 | F3F7 | F3F7 | 1002965-B1 |
Low level format | No | Yes | Yes | Yes |
Partitioning | FDISK | FDISK | FDISK | FDISK |
High level format | Yes | Yes | Yes | Yes |
Diagnostics | - | Yes | Yes | - |
Formatted size | 180 Mb. | 85 Mb. | 133 Mb. | 89 Mb. |
Data file transfers| Yes o.k.| Yes o.k.| Yes o.k. | Yes o.k. |
==================================================================
ONTRACK DISK MGR. | | | | |
Low level format | Yes | No | No | Yes |
Partitioning | Yes | Yes | Yes | Yes |
High level format | Yes | Yes | Yes | Yes |
Formatted size | 182 Mb. | 89 Mb. | 135 Mb. | 90 Mb. |
Data file transfers| Yes o.k.| Yes o.k. | Yes o.k. | Yes o.k. |
==================================================================
SPEEDSTOR | | | | |
Low level format | Yes | No | No | No |
Partitioning | Yes | Yes | Yes | Yes |
High level format | Yes | Yes | Yes | Yes |
Formatted size | 182 Mb. | 89 Mb. | 135 Mb. | 90 Mb. |
Data file transfers| Yes o.k.| Yes o.k. | Yes o.k.| Yes o.k. |
==================================================================
TRANSFER RATE | Kilobytes per second. |
Mace HPERF | 1867.3 | 1239.6 | 1272.1 | 1239.6 |
PC Labs. | 6.97 Secs| 7.19 Secs| 7.04 Secs| 7.93 Secs |
Coretest | 550.6 | 646.5 | 583.5 | 575.3 |
Power Meter | 663.4 | 504.02 | 513.72 | 522.7 |
==================================================================
AVERAGE SEEK | Milliseconds. |
Mace HPERF | 26.8 | 29.4 | 29.4 | 32.5 |
PC Labs | 26.36 | 29.83 | 29.0 | 32.68 |
Coretest | 26.4 | 29.2 | 29.5 | 32.1 |
Power Meter | 26 | 28.97 | 28.5 | 31.9 |
==================================================================
1. This configuration would not work at the high CPU clock rate
of 12.4 Mhz. It did work at the lower rate of 6.2 Mhz.
CONTROLLER TESTS. REV 1.
/--------- CONTROLLERS.-------------\
=========================================================
| Make | West. Dig| West. Dig| | |
| Model |7000 FASST|ATXT FASST| | |
| Revision | - | Bios 3.32| | |
-------==========================================================
| | Make | Fujitsu | Fujitsu | | |
|DRIVE | Model | M2613SA | M2613SA | | |
| | Revision | C6 | C6 | | |
-------+-----------+----------+----------+----------+------------
| | Make | Compaq | Compaq | | |
|SYSTEM| Model | 286 | 286 | | |
| |Clock rate | 8 Mhz. | 8 Mhz. | | |
-------+-----------+----------+----------+----------+------------
| S/W | Type | DOS | DOS | | |
| | Version | 3.3 | 3.3 | | |
-----------------------------------------------------------------
Notes | 1 and 2 | 2 | | |
=================================================================
ON BOARD FIRMWARE | | | | |
Low level format | Yes | Yes | | |
Partitioning | Yes | Yes | | |
High level format | Yes | Yes | | |
Diagnostics | Yes | Yes | | |
Formatted size | 130 Mb. | 130 Mb. | | |
System file xfers. | Yes o.k.| Yes o.k.| | |
==================================================================
ONTRACK DISK MGR. | | | | |
Low level format | No | No | | |
Partitioning | Yes | Yes | | |
High level format | Yes | Yes | | |
Formatted size | 136 Mb. | 136 Mb. | | |
System file xfers. | Yes o.k.| Yes o.k.| | |
==================================================================
SPEEDSTOR | | | | |
Low level format | No | No | | |
Partitioning | Yes | Yes | | |
High level format | Yes | Yes | | |
Formatted size | 136 Mb. | 136 Mb. | | |
System file xfers. | Yes o.k.| Yes o.k.| | |
==================================================================
TRANSFER RATE | Kilobytes per second. |
Mace HPERF | 2206.8 | 2206.8 | | |
Mace HDTEST | 7.69 Secs| 18.78 Sec| | |
Coretest | 504.5 | 148.7 | | |
Power Meter | 505.3 | 2338.9 | | |
==================================================================
AVERAGE SEEK | Milliseconds. |
Mace HPERF | 24.2 | 18 | | |
Mace HDTEST | 23.9 | 17.8 | | |
Coretest | 24.2 | 16.7 | | |
Power Meter | 23.58 | 16.6 | | |
==================================================================
1. Must be set to Asynchronous mode. Will not work in Synch.
2. Installed using Columbia Data Systems software, rel. 3.34.
CONTROLLER TESTS. REV 1.
/--------- CONTROLLERS.-------------\
=========================================================
| Make | WEST.DIG.| SMS |Futr. Dom.| Adaptec |
| Model |WD7000-ASC| OMTI 822 | TMC 860 | AHA-1540A |
| Revision | -035 | B | B | C |
| BIOS | -064 | B1 | 6.0A | A |
-------==========================================================
| | Make | Fujitsu | Fujitsu | Fujitsu | Fujitsu |
|DRIVE | Model | M2613SA | M2613SA | M2613SA | M2613SA |
| | Revision | C6 | C6 | C6 | C6 |
| | Firmware | | | | |
| | | | | | |
|------+-----------+----------+----------+----------+------------|
| | Make | DELL | DELL | DELL | DELL |
|SYSTEM| Model | 200 | 200 | 200 | 200 |
| | | | | | |
-------+-----------+----------+----------+----------+------------
| S/W | Type | NOVELL | NOVELL | NOVELL | NOVELL |
| | | NETWARE | NETWARE | NETWARE | NETWARE |
| | | 286 | 286 | 286 | 286 |
| | Version | 2.15 | 2.15 | 2.15 | 2.15 |
| | Features | SFT | SFT | SFT | SFT |
| | | | | | |
-----------------------------------------------------------------
Notes | 1 | 2 | 3 | 4 |
| | | | |
-----------------------------------------------
NOTES.
1. Used Device Driver from Columbia Data Systems ver. 3.34
2. Uses SMS Device Driver for Netware 286
3. Uses Future Domain Netware 286 driver V1.4
4. Used ONTRACK installation software version 1.0
CONTROLLER TESTS. REV 1.
รจ
/--------- CONTROLLERS.-------------\
=========================================================
| Make | SUN | | | |
| Model | Internal | | | |
| Revision | | | | |
-------==========================================================
| | Make | Fujitsu | | | |
|DRIVE | Model | M2612SA | | | |
| | Revision | C7 | | | |
|------+-----------+----------+----------+----------+------------|
| | Make | SUN | | | |
|SYSTEM| Model | 4/370 | | | |
| | | | | | |
| | | | | | |
-------+-----------+----------+----------+----------+------------
| S/W | Type | SUN OS. | | | |
| | Version | 4.0 | | | |
| |Boot tape | 4.0.3 | | | |
| | | SPARC | | | |
-----------------------------------------------------------------
Notes | 1 | | | |
| | | | |
-----------------------------------------------
COMMENTS.
Note 1. See Tech. Tip. for information on installation.
(The SCSI protocol chip is NCR 53C90)
We suggest that the M2614 drive be used, rather than
the M2612 which is too small in capacity to be practical
in use. The M2613 may be O.K. for a single user, but
again is probably too small for a Multi-user environment.