CONTROLLER TESTS. REV 2.
/--------- CONTROLLERS.-------------\
=========================================================
| Make | W.D. | Adaptec | Adaptec |Rancho Tech.|
| Model |7000 FASST| AHA1542A | AHA1542B | RT10-AT |
| Revision | 03 | | H | A |
-------==========================================================
| | Make | Fujitsu | Fujitsu | Fujitsu | Fujitsu |
|DRIVE | Model | M2263SA | M2263SA | M2263SA | M2263SA |
| | Revision | A0 | B6 | A0 | B2 |
-------+-----------+----------+----------+----------+------------
| | Make | Dell 286 | I.B.M. | Dell 286 | IBM. |
|SYSTEM| Model | 200 | AT 286 | 200 | AT |
| | Clock rate| 12.4 Mhz | 8 Mhz | 12 Mhz. | 8 Mhz. |
-------+-----------+----------+----------+----------+------------
| S/W | Type | DOS | DOS | DOS | DOS |
| | Version | 3.3 | 3.3 | 3.3 | 3.3 |
-----------------------------------------------------------------
Notes | 1 | 2 | | |
=================================================================
ON BOARD FIRMWARE | SST 3.35 | | F3F7 | |
Low level format | Yes | Yes | Yes | |
Partitioning | Yes | - | Yes | |
High level format | Yes | - | Yes | |
Diagnostics | Yes | verify | Yes | |
Formatted size | 640 + | | 650 Mb | |
Data file transfers| Yes | Yes | Yes O.K. | |
==================================================================
ONTRACK DISK MGR. | | | | |
Low level format | No | No | No | |
Partitioning | No | Yes | Yes | |
High level format | No | - | Yes | |
Formatted size | | 670 Mb | 670 Mb | |
Data file transfers| Yes | Yes | Yes O.K.| |
==================================================================
SPEEDSTOR | | | | |
Low level format | No | No | No | |
Partitioning | No | Yes | Yes | |
High level format | No | - | Yes | |
Formatted size | _ | 670 Mb | 670 Mb | |
Data file transfers| _ | | Yes O.K.| |
==================================================================
TRANSFER RATE | Kilobytes per second. |
Mace HPERF | 14565 | 1929.2 | 1916.5 | 3832.9 |
PC Labs. | | | 3.89 Secs| 4.12 Secs. |
Coretest |see detail| 1062.5 | 1008.2 | 866.3 |
Power Meter | 8983 | 1158.8 | 1078.75 | 1911.18 |
==================================================================
AVERAGE SEEK | Milliseconds. |
Mace HPERF | 10.3 | 19.3 | 18.5 | 16.9 |
PC Labs | | | 19.23 | |
Coretest | 10.7 | 20.3 | 19.9 | 16.1 |
Power Meter | 9.95 | 19.6 | 18.79 | 15.0 |
==================================================================
1. WD7000 FASST ASC Host adapter must be prepared using Columbia
Data System software. SYS is used to transfer system files.
1 + 2. When using Speedstor to PARTITION the drive some inconsistency
was experienced in getting the full available capacity.
CONTROLLER TESTS. REV 2.
/--------- CONTROLLERS.-------------\
=========================================================
| Make |Futr. Dom.|Sun Micro | Always | SMS |
| Model | TMC 860 | 5231 | IN 2000 | OMTI 822 |
| Revision | | 3.0 | 3.04 | B |
-------==========================================================
| | Make | Fujitsu | Fujitsu | Fujitsu | Fujitsu |
|DRIVE | Model | M2263SA | M2263SA | M2263SA | M2263SA |
| | Revision | A6 | A6 | A6 | A0 |
-------+-----------+----------+----------+----------+------------
| | Make | Mitac | Mitac | Mitac | DELL |
|SYSTEM| Model |200 AT 286|200 AT 286|200 AT 286| 200 |
| | Clock rate| 12 Mhz. | 12 Mhz | 12 Mhz. | 12.4 Mhz |
-------+-----------+----------+----------+----------+------------
| S/W | Type | DOS | DOS | DOS | Dos |
| | Version | ? | 4.01 | 4.01 | 3.3 |
-----------------------------------------------------------------
Notes | 1 | 2 and 3 | 3 | |
=================================================================
ON BOARD FIRMWARE | | | | |
Low level format | - | N/A | N/A | Yes |
Partitioning | - | 'FDISK ' | 'FDISK' | 'FDISK' |
High level format | - | 'FORMAT' | 'FORMAT' | 'FORMAT' |
Diagnostics | - | - | - | - |
Formatted size | - | 670.3 Mb.| 670.3 Mb.| 651 Mb. |
Data file transfers| - | Yes O.K. | Yes O.K. | Yes O.K. |
==================================================================
ONTRACK DISK MGR. | | | | |
Low level format | - | - | - | No |
Partitioning | - | - | - | No |
High level format | - | - | - | No |
Formatted size | - | - | - | - |
Data file transfers| - | - | - | No |
==================================================================
SPEEDSTOR | | | | |
Low level format | - | - | - | No |
Partitioning | - | - | - | Yes |
High level format | - | - | - | Yes |
Formatted size | - | - | - | 671 Mb. |
Data file transfers| - | - | - | Yes O.K. |
==================================================================
TRANSFER RATE | Kilobytes per second. |
Mace HPERF | - | - | - | 482.3 |
PC Labs. | - | - | - | |
Coretest | - | - | - | 1003.9 |
Power Meter | - | - | - | 1079.9 |
==================================================================
AVERAGE SEEK | Milliseconds. |
Mace HPERF | - | - | - | 20 |
PC labs. | - | - | - | 19.33 |
Coretest | - | - | - | 20.3 |
Power Meter | - | - | - | 19.1 |
==================================================================
1. Drive firmware must be at rev. E.
2. Drive firmware must be at rev. F. SCSI I.D. set to '0'
3. On "Columbia Data Systems" disk utility, transferred data at
2.6 Mbytes/sec.
- means information not provided.
CONTROLLER TESTS. REV 1.
/--------- CONTROLLERS.-------------\
=========================================================
| Make |Rancho. Tk|Futr. Dom.| | |
| Model |RT-1000 MC| MCS 350 | | |
| Revision | 5.05P | 1.2 | | |
-------==========================================================
| | Make | Fujitsu | Fujitsu | | |
|DRIVE | Model | M2263SA | M2263SA | | |
| | Revision | A0 | A0 | | |
-------+-----------+----------+----------+----------+------------
| | Make | IBM | IBM | | |
|SYSTEM| Model |PS2 Mod.60|PS2 Mod.60| | |
| |Clock rate | 10 Mhz. | 10 Mhz. | | |
-------+-----------+----------+----------+----------+------------
| S/W | Type | PCDOS | PCDOS | | |
| | Version | 3.3 | 3.3 | | |
-----------------------------------------------------------------
Notes | | 1 | | |
=================================================================
ON BOARD FIRMWARE | FMT1K | Note 1 | | |
Low level format | Yes | Yes | | |
Partitioning | FDISK | FDISK | | |
High level format | FORMAT | FORMAT | | |
Diagnostics | - | - | | |
Formatted size | 671.9 Mb.| 671.4 | | |
Data file xfers. | Yes o.k. | Yes o.k. | | |
==================================================================
ONTRACK DISK MGR. | 4.01P | 4.01P | | |
Low level format | Yes | Yes | | |
Partitioning | Yes | Yes | | |
High level format | Yes | Yes | | |
Formatted size | 670 Mb. | 671 Mb. | | |
Data file xfers. | Yes o.k.| Yes o.k.| | |
==================================================================
SPEEDSTOR | | | | |
Low level format | No | No | | |
Partitioning | No | No | | |
High level format | No | No | | |
Formatted size | - | - | | |
Data file xfers. | No | No | | |
==================================================================
TRANSFER RATE | Kilobytes per second. |
Mace HPERF | 321.2 | 89.8 | | |
PC Labs | 10.43 Sec| 3.84 Secs| | |
Coretest | 323.8 | 346 | | |
Power Meter | 243.6 | 1437.2 | | |
==================================================================
AVERAGE SEEK | Milliseconds. |
Mace HPERF | 16.7 | 16.9 | | |
PC Labs. | 16.64 | 16.42 | | |
Coretest | 17.2 | 16.3 | | |
Power Meter | 15.69 | 15.7 | | |
==================================================================
1. Uses Disk Maestro 5.1 installation software.
CONTROLLER TESTS. REV 1.
/--------- CONTROLLERS.-------------\
=========================================================
| Make | WEST.DIG.| SMS |Futr. Dom.| Adaptec |
| Model |WD7000-ASC| OMTI 822 | TMC 860 | AHA-1540A |
| Revision | -035 | B | B | D |
| BIOS | -064 | B1 | 6.0A | A |
-------==========================================================
| | Make | Fujitsu | Fujitsu | Fujitsu | Fujitsu |
|DRIVE | Model | M2263SA | M2263SA | M2263SA | M2263SA |
| | Revision | A0 | A0 | A0 | A0 |
| | Firmware | E | E | E | E |
| | | | | | |
|------+-----------+----------+----------+----------+------------|
| | Make | DELL | DELL | DELL | DELL |
|SYSTEM| Model | 200 | 200 | 200 | 200 |
| | | | | | |
-------+-----------+----------+----------+----------+------------
| S/W | Type | NOVELL | NOVELL | NOVELL | NOVELL |
| | | NETWARE | NETWARE | NETWARE | NETWARE |
| | | 286 | 286 | 286 | 286 |
| | Version | 2.15 | 2.15 | 2.15 | 2.15 |
| | Features | SFT and | SFT | SFT | SFT |
| | | Advance | | | |
-----------------------------------------------------------------
Notes | 1 | 2 | 3 | 4 |
| | | | |
-----------------------------------------------
NOTES.
1. Uses SST Device Driver from Columbia Data Systems
2. Uses SMS Device Driver for Netware 286
3. Uses Future Domain Netware 286 driver V1.4
4. Used ONTRACK installation software version 1.0
CONTROLLER TESTS. REV 2.
/--------- CONTROLLERS.-------------\
=========================================================
| Make | Internal | Internal | | |
| Model | - | - | | |
| Revision | - | - | | |
-------==========================================================
| | Make | Fujisu | Fujitsu | | |
|DRIVE | Model | M2263SA | M2263SA | | |
| | Revision | A7 | A6 | | |
| | Firmware | 81139H | 81139F | | |
| | Capacity | 620 Mb. | 650 Mb. | | |
|------+-----------+----------+----------+----------+------------|
| | Make | Digital | Digital | | |
|SYSTEM| Model |Vaxstation|Decstation| | |
| | | 3100 | 3100/20 | | |
| | | | | | |
-------+-----------+----------+----------+----------+------------
| S/W | Type | VMS | Ultrix | | |
| | Version | 5.2 | 3.1 | | |
| | | | | | |
-----------------------------------------------------------------
Notes | 1 | 2 | | |
| | | | |
-----------------------------------------------
Special requirements to make the drive work in the configurations
above.
NOTES.
Note 1. Drive firmware revision must be at least rev. 'H'.
Remove jumpers off CNH2 pins 1 to 2, CNH2 pins 15 to 16
and CN9 pins 5 to 6.
The drive was installed on standard Vaxstation 3100 SCSI
controller board and the normal VMS disk installation
procedure was performed.
Note 2. Drive SCSI firmware must be at least Rev. 'F'.
Remove jumpers off CNH2 pins 1 to 2.
Drive was installed on standard Decstation 3100/20 SCSI
controller board and normal Ultrix disk installation
procedure was performed.