AdapterID 0708h
AdapterName "BusLogic 32 Bit Bus Master MCA-to-SCSI Host Adapter (v1.50)"
NumBytes 4
fixedResources
pos[0]=xxxxxxx1b
pos[1]=000000xxb
pos[2]=xxx0x0xxb
pos[3]=110xxxxxb
nameditem
Prompt "BIOS Address"
Choice "DC000h"
pos[0]=111xxxxxb
mem 0dc000h-0dffffh
Choice "Disable"
pos[0]=000xxxxxb
Choice "D8000h"
pos[0]=110xxxxxb
mem 0d8000h-0dbfffh
Choice "D4000h"
pos[0]=101xxxxxb
mem 0d4000h-0d7fffh
Choice "D0000h"
pos[0]=100xxxxxb
mem 0d0000h-0d3fffh
Choice "CC000h"
pos[0]=011xxxxxb
mem 0cc000h-0cffffh
Choice "C8000h"
pos[0]=010xxxxxb
mem 0c8000h-0cbfffh
Choice "C4000h"
pos[0]=001xxxxxb
mem 0c4000h-0c7fffh
Help
"This selects the memory location of the host adapter's
BIOS PROM. Conflicting assignments will be marked with
an asterick and must be changed to use the host adapter.
To disable the host adapter's BIOS PROM, choose the
'Disable' option. Note, if two Micro Channel host adapters
reside in the system one of them must have its BIOS PROM
disabled. The default setting is DC000h."
nameditem
Prompt "I/O Port Address"
Choice "330h"
pos[0]=xxx0xxxxb
pos[1]=00000011b
io 0330h-0333h
Choice "334h"
pos[0]=xxx1xxxxb
pos[1]=00000011b
io 0334h-0337h
Choice "234h"
pos[0]=xxx1xxxxb
pos[1]=00000010b
io 0234h-0237h
Choice "134h"
pos[0]=xxx1xxxxb
pos[1]=00000001b
io 0134h-0137h
Choice "230h"
pos[0]=xxx0xxxxb
pos[1]=00000010b
io 0230h-0233h
Choice "130h"
pos[0]=xxx0xxxxb
pos[1]=00000001b
io 0130h-0133h
Help
"This option selects the I/O Port of the host adapter.
Conflicting assignments are marked with an asterisk and
must be changed to use the host adapter. Default I/O
address is 330h."
nameditem
Prompt "Arbitration Level"
Choice "Level_5"
pos[3]=xxxx0101b
arb 5
Choice "Level_6"
pos[3]=xxxx0110b
arb 6
Choice "Level_7"
pos[3]=xxxx0111b
arb 7
Choice "Level_4"
pos[3]=xxxx0100b
arb 4
Choice "Level_3"
pos[3]=xxxx0011b
arb 3
Choice "Level_1"
pos[3]=xxxx0001b
arb 1
Choice "Level_0"
pos[3]=xxxx0000b
arb 0
Help
"This selects the DMA channel the host adapter will use to
transfer data. Conflicting assignments will be marked with
an asterick and must be changed to use the host adapter. The
default level is 5."
nameditem
Prompt "Arbitration Fairness"
Choice "On"
pos[3]=xxx0xxxxb
Choice "Off"
pos[3]=xxx1xxxxb
Help
"Bus Arbitration Fairness controls whether the host adapter
implements the fairness alorigthm after it is preempted from
the Micro Channel. Default is fairness enabled."
nameditem
Prompt "Interrupt Request"
Choice "Int_15"
pos[0]=xxxx111xb
int 15d
Choice "Int_14"
pos[0]=xxxx110xb
int 14d
Choice "Int_12"
pos[0]=xxxx100xb
int 12d
Choice "Int_11"
pos[0]=xxxx011xb
int 11d
Choice "Int_10"
pos[0]=xxxx010xb
int 10d
Choice "Int_9"
pos[0]=xxxx001xb
int 9d
Help
"This selects the interrupt channel the host adapter will
use to report status. Conflicting assignments will be
marked with an asterick and must be changed to use the
host adapter. The default is interrupt 15."
nameditem
Prompt "Data Streaming"
Choice "Disable"
pos[2]=xxxxxxx0b
Choice "Enable"
pos[2]=xxxxxxx1b
Help
"The streaming data procedure transfers data blocks by using a single
address followed by multiple 16- or 32-bit data transfers within a
single streaming data cycle. If data streaming is enabled, the host
adapter can achieve a maximum data transfer rate of 40 MBytes/sec on
the Micro Channel bus. If data streaming is disabled, the maximum
data transfer rate is 20 MBytes/sec."
nameditem
Prompt "Adapter SCSI Bus ID"
Choice "Id_7"
pos[2]=111xxxxxb
Choice "Id_6"
pos[2]=110xxxxxb
Choice "Id_5"
pos[2]=101xxxxxb
Choice "Id_4"
pos[2]=100xxxxxb
Choice "Id_3"
pos[2]=011xxxxxb
Choice "Id_2"
pos[2]=010xxxxxb
Choice "Id_1"
pos[2]=001xxxxxb
Choice "Id_0"
pos[2]=000xxxxxb
Help
"This is the SCSI ID of the host adapter. The default setting
is SCSI ID 7."
nameditem
Prompt "Adapter Initiate Sync Negotiation"
Choice "On"
pos[2]=xxxxxx1xb
Choice "Off"
pos[2]=xxxxxx0xb
Help
"Synchronous transfer on the SCSI bus will be initiated by the
host adapter if 'On'. The default setting is On."
nameditem
Prompt "Adapter SCSI Parity Checking"
Choice "On"
pos[2]=xxx1xxxxb
Choice "Off"
pos[2]=xxx0xxxxb
Help
"The host adapter will check SCSI Parity if 'On'. The default
setting is On."
nameditem
Prompt "DOS Disk Space > 1GBytes"
Choice "Off"
pos[2]=xxxx0xxxb
Choice "On"
pos[2]=xxxx1xxxb
Help
"The host adapter will change cylinder, head, & sector per track
to support drive capacity greater than 1GigaByte if 'On'. The
default setting is Off."