Ú¿ ÚÂÄ¿ ¿ ÚÄÂÂÄ¿ ÚÂÄÄ¿ Ú¿ ÚÂÄÄ¿ ÚÂÄÄ¿ ô ô ³ ³ ô ÃÅÄ Ã´ ÃÅÄ Ã´ ÀÙ ÀÙ ÀÄÙ ÀÙ ÀÁÄÄÙ ÀÁÄÄÙ ÀÁÄÄÙ ÀÁÄÄÙ ÚÂÄÄ¿ ÚÂÄÄ¿ ÚÂÄÄ¿ ÚÄÂÂÄ¿ Ú¿ ¿ ÚÂÄ¿ ÚÂÄ¿ ÚÂÄÄ¿ ÀÁÄ¿ ô ³ ÃÅÄ Ã´ ô ¿ ³ ÚÅÁÄÁ¿ ÃÅÄÁ¿ ÃÅÄ ÀÄÄÁÙ ÀÁÄÄÙ ÀÙ ÀÙ ÀÁÄÁÄÙ ÀÙ Ù ÀÙ Ù ÀÁÄÄÙ I n t e l e c S o f t w a r e ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ ³ Page-Me! ³ ÚÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿³ ³Page-Me! allows you to let your users reach you @ your numeric pager number!³³ ³Each user can assign their own "code" and you can "block out" specific users³³ ³from using this utility. It has a "time table" file so you can restrict when³³ ³it is used. So even if you only have a LOCAL paging service, LD callers canÃÙ ³even page you at your pager! And much more! ³ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ ³ Installation Page-Me! ³ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ Installation of Page-Me! is really very simple. Page-Me! should be installed in your CMD.LST as shown below: Command Security PPE/MNU File -or- Keystroke Replacement ======= ======== ======================================== PAGE-ME! 40 C:\PCB\PPE\PM\PAGE-ME!.PPE Make the security level at whatever you desire and adjust for your paths. For more info on CMD.LST see PCB docs. If you are NOT setting up Page-Me! for the FIRST time, be careful not to over-write any of your files with the lists or time tables that I include with the distribution files. I include them as samples and mine may not match with yours and I'd hate to see your settings lost or overwritten. Make sure you edit your config file appropriately. If Registered, place a copy of your PAGE_ME!.KEY (or POWERPAK.KEY) in the same directory as the PPE. So... unzip the contents of the Page-Me! ZIP to the directory you'll be running it from. Then edit the PAGE-ME!.CNF and display screens to your BBS. ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ ³ PAGE-ME!.CNF ³ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´ ³ SYSOP ³ Line 1 TO: Field if Message is to be sent after page ³ 9 ³ Line 2 Conference message is sent in ³ R ³ Line 3 R/N Message Security ³ 123-4567 ³ Line 4 Your pager phone number ³ 20 ³ Line 5 Minimum security level ³ 60 ³ Line 6 Maximum security level * ³ REVERSE ³ Line 7 Reverse the function of the bad names list ³ Y ³ Line 8 Y/N Send SysOp a message when page is sent ³ 7 ³ Line 9 Days to add to todays date for packout date ³ Y ³ Line 10 Y/N to log as a door being opened ³ ATH1 ³ Line 11 Modem String to take modem off hook ³ ATH0 ³ Line 12 Modem String to put modem on hook ³ ATDT ³ Line 13 Dial Prefix for modem ** ³ ,,,, ³ Line 14 String to add between number and pager code ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ * Line 7, the REVERSE entry, allows you to reverse how the BADNAMES.LST is used. If you put REVERSE on line 7 then the "bad names" in the list will be looked at as "approved for use" names. You'd use this feature if you have "fewer" names that you want to allow to use this utility. If you want to use the bad names list as just that, then leave line 7 as blank. Lastly, if you are having messages sent to you they will be addressed "from" PAGE-ME! so add this name to your PCBoard TCAN file so nobody can logon under that name and read these messages. ** This string will be inserted between the number and the pager code. In the above config, the full dialing string would be ATDT123-4357,,,,code where code is the pager code selected. ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ ³ TIME ³ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´ ³ 000000000011111111112222 ³ ³ 012345678901234567890123 ³ ³ ³ ³ SU NNNNNNNNNNNNNNNNNNNNNNNN ³ ³ MO NNNNNNNYYYYYYYYYYYNNNNNN ³ ³ TU NNNNNNNYYYYYYYYYYYNNNNNN ³ ³ WE NNNNNNNYYYYYYYYYYYNNNNNN ³ ³ TH NNNNNNNYYYYYYYYYYYNNNNNN ³ ³ FR NNNNNNNYYYYYYYYYYYNNNNNN ³ ³ SA NNNNNNNNNNNNNNNNNNNNNNNN ³ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ Page-Me! a time table similar to FONE-VER to determine if a page is OK for a particular time. As you can see above, I have mine set to allow pages only between 7am and 6pm Monday through Friday and not at all on the weekends. If you do not want to permit calls during a certain time place an N in that day's/hour's column. The first column of Y's is at 00:00 thru 00:59 am, the last column of Y's is 23:00 thru 23:59 pm. The top left corner of the block must start at row 4, column 4. ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ ³ BADNAMES.LST ³ This is a list of names of users you do not want ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´ to permit access to Page-Me!. If you use the REVERSE ³ JIM BROWN ³ feature of Page-Me! then these names would be the ³ AL GREEN ³ only names allowed to use this utility unless their ³ RED SKELTON ³ security level was within the minimum and maximum ³ KAREN BLACK ³ security level ranges. ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ There are a few "display files" used by Page-Me. They are WELC which is displayed upon entering the door, and BADNAME which is displayed to a user whose name was found in the BADNAMES.LST file. A file called BADTIME will be displayed to users who call outside the times that you specified in the TIME file. Also, files called ########.COD where ######## is a number unique for each user to enter a specific code of their choosing or one of your "assigning". If you want users to be able to pull from a menu of codes that YOU have defined, then create these files: MENU and MENU.LST. MENU is the file displayed to users that shows the page reasons that you've assigned, and MENU.LST contains the codes corresponding to options in the MENU file. See the included MENU/MENU.LST files for details on this feature. Page-me will not work without these files, so you should have at least 1 entry. That's about it, it's pretty much straight-forward but if you have any questions, feel free to drop me a note on the Intelec Network in the IS_Support conference. You are permitted to use Page-Me! for a period of 30 days for eval- uation purposes, after which it must be registered or removed from your system. Registration grants you a license to use Page-Me! on the (1) BBS in which it is registered to. We've the right to terminate this license if licensee violates this agreement. Using Page-Me! on more than one (1) BBS or sharing the registration or validation codes constitutes breach of agreement and licensing will be revoked. You agree that Intelec Software makes no warranties of any kind, expressed or implied, with respect to the quality, performance, accuracy, or fitness of Page-Me!. In no event is Intelec software liable to you for any damages, including any lost profits, lost savings or other incidental or consequential damages arising from your use or inability to use Page-Me!, or for any claim by any other party.