PRODUCT : Turbo C++ NUMBER : 807 VERSION : 1.01 OS : DOS DATE : October 19, 1993 PAGE : 1/1 TITLE : "Cannot generate COM file: segment-relocatable items present" This TLINK error is displayed when using any floating point routines, far calls or C++ stream functions in a program compiled in the tiny model and linked using the -t linker option to create a .COM file. Note: Programs using C++ stream I/O which compiled successfully with the Zortech compiler will fail with this error when compiled under Turbo C++. DISCLAIMER: You have the right to use this technical information subject to the terms of the No-Nonsense License Statement that you received with the Borland product to which this information pertains.