STANDARD MICROSYSTEMS CORPORATION Novell NetWare OS/2 Workstation Requester Driver For Ethernet LAN Adapters INSTALLATION GUIDE This software is licensed by SMC for use by its customers only. Copyright (c) 1993 Standard Microsystems Corporation. All rights reserved. This driver supports all 8216 (Ultra) and 80xx (PLUS) Series ISA and Micro Channel Ethernet adapters. This document explains how to: o Use EZStart or a manual procedure to copy the NetWare OS/2 workstation requester driver from the SuperDisk. o Install the driver using the Netware OS/2 requester INSTALL program. COPYING THE DRIVER FILES EZStart Method: Select 'Cancel' and then 'Copy Files' to copy all the files used by this driver from the SuperDisk to the Destination Directory recommended by EZStart, or to a different directory that you specify. Manual Method: The OS/2 Requester driver, SMC8000.SYS, and the NET.CFG file are located in the OS2_ODI subdirectory on the SuperDisk. The driver is installed using the NetWare INSTALL program. LOADING THE DRIVER Use the following instructions in conjunction with those in the NetWare Workstation for OS/2 manual: 1. Load the NetWare INSTALL program according to the instructions in the NetWare manual. 2. Select "Requester on workstation" from the menu. 3. Specify the source and target directories. 4. Select "Edit CONFIG.SYS..." 5. Select "SMC8000.SYS" from the list. If the driver is not on the list, enter SMC8000.SYS. 6. Select or deselect any remaining options, then select "Save". In the "Save File As:" field, type "CONFIG.SYS". 7. In the "Copy Requester Files" window, select "Copy". 8. Proceed with the instructions in the NetWare manual until the installation is complete. EDITING THE CONFIG.SYS FILE 1. Copy the file SMC8000.SYS from the OS2_ODI subdirectory of the SuperDisk to the NETWARE subdirectory on the workstation. 2. Save the file, then reboot the computer. INSTALLING MULTIPLE ADAPTERS If two adapters are installed, you will need to modify the NET.CFG file, located in the OS2_ODI subdirectory of the SuperDisk, and copy it to the SMCNOV or the directory where the SMC OS2 ODI driver is located. To modify the file, use any text editor to open the file and add the following lines: LINK DRIVER SMC8000 PORT XXX (ISA adapters) SLOT X (Micro-channel adapters only) LINK DRIVER SMC8000 PORT XXX (ISA adapters) SLOT X (Micro-channel adapters only) (where XXX is the I/O address of the adapter in hexadecimal) The first adapter should be the one with the lowest I/O base address (use EZStart to obtain each adapter's I/O base address). ERROR MESSAGES Here is the list of error messages the driver may display: "Adapter hardware failure detected (initialization)." The adapter did not pass the initialization process. Check the adapter for configuration conflicts. "Adapter hardware failure detected (self-test)." The adapter did not pass the initialization self-test process due to a hardware problem. Check the adapter for configuration conflicts. "Adapter unable to insert into network." The adapter did not connect to the network due to a hardware error. Check the adapter for configuration conflicts. Check the adapter is inserted properly into the slot connector. "Adapter IRQ higher than 7 not valid in 8-bit slot." The I/O base address specified cannot be used if the adapter is inserted into an 8-bit slot. Select a different IRQ number. "No Ethernet Adapters Found." The driver could not detect an adapter installed in the system. Check the adapter is inserted properly into the slot connector. "Invalid Ethernet node address specified." The node address specified in the NET.CFG file was illegal. Broadcast and multi-cast addresses are not allowed as valid node addresses. Use the node address over-ride with caution as this can cause problems on your network. "One or more NET.CFG parameters are missing or invalid." A driver parameter required to load the driver is missing from the NET.CFG file. Add the parameter(s) and re-load the driver. "I/O address in NET.CFG is on illegal boundary." The specified PORT address in the NET.CFG file is not correct. Verify the adapter I/O address from the soft-configuration or jumper setting and make the necessary changes to the NET.CFG file. "I/O address in NET.CFG is out of range." The I/O base address specified in the NET.CFG file for the AT-bus adapter is out of range of supported values. Verify the adapter I/O address from the soft-configuration or jumper setting and make the necessary changes to the NET.CFG file. "IRQ in NET.CFG does not match adapter configuration." The IRQ number specified in the NET.CFG file for the AT-bus adapter does not match the detected configuration. Verify the adapter IRQ setting from the soft-configuration or jumper setting and make the necessary changes to the NET.CFG file. "IRQ specified in NET.CFG is out of range." The IRQ number specified in the NET.CFG file for the AT-bus adapter is out of range of supported values. Verify the adapter IRQ setting from the soft-configuration or jumper setting and make the necessary changes to the NET.CFG file. "RAM address in NET.CFG is on illegal boundary." The specified MEM address in the NET.CFG file is not correct. Verify the adapter RAM memory address from the soft-configuration or jumper setting and make the necessary changes to the NET.CFG file. "RAM address in NET.CFG is out of range." The RAM address specified in the NET.CFG file for the AT-bus adapter is out of range of supported values. Verify the adapter RAM memory address from the soft-configuration or jumper setting and make the necessary changes to the NET.CFG file. "RAM size specified in NET.CFG is out of range." The RAM size specified in the NET.CFG file for the AT-bus adapter is out of range of supported values. Verify the adapter RAM memory address from the soft-configuration or jumper setting and make the necessary changes to the NET.CFG file. "RAM size in NET.CFG does not match adapter config." The MEM length parameter in the NET.CFG file was invalid. Check the adapter configuration and make the necessary changes to the NET.CFG file. "Cannot access adapter RAM properly." The adapter could read or write the adapter RAM. Verify that another adapter does not share the same memory space as the LAN adapter. EtherCard Ultra, EtherCard PLUS, TokenCard, and SuperDisk are trademarks, and SMC and Standard Microsystems are registered trademarks of Standard Microsystems Corporation. Other Trademarks mentioned herein belong to their respective companies.