32-Bit PCI (fast) Ethernet Adapter NetWare DOS ODI Driver Installation ====================================== NetWare DOS ODI Driver Installation (NetWare 3.11) ================================================== Requirements: ------------- 32-Bit PCI (fast) Ethernet Adapter Driver Diskette (PCI40.LAN) Installation Procedure: ----------------------- Before you start with the installation process, make sure that the Novell NetWare 386 v3.11 server is properly installed. Your adapter should also be installed in your workstation. 1. Insert the driver diskette into your floppy drive (A: or B:) and check the contents of subdirectory \NETWARE\ODI\3.1X It should contain the following file : PCI40.LAN <--- Novell NetWare V4.X, 3.1X Server Driver for 32-Bit PCI Fastnet/Ethernet Adapter AUTOEXEC.NCF ETHERTSM.NLM LSLENH.NLM MONITOR.NLM MSM31X.NLM PATCHMAN.NLM 2. Copy the above LAN files from the driver diskette into the NetWare 386 subdirectory of your server. 3. Run SERVER.EXE from your server. You will see a series of NetWare messages onscreen. 4. You need to load all required NLM modules before you can load the server driver. You can set up the AUTOEXEC.NCF file in the \netware\odi\3.1X directory to run the loading. 5. When the NetWare 386 prompt appears (preceded by a colon mark), load your server driver. Simply type: : LOAD [d:]PCI40 TP[AUI,BNC,AUTODETECT,TP_FULL_DUPLEX] LINE_SPEED=100 [10,100] /* for Fastnet only */ FRAME=ETHERNET_802.3 <Enter> (Command Syntax : LOAD [d:]<Driver Name> <MEDIUM TYPE> LINE_SPEED=<Line Speed> FRAME=<FRAME TYPE>) ********************************************************************** * IMPORTANT! * * * * MEDIUM TYPE default for Ethernet Adapter is AUTODETECT, * * for Fastnet Adapter is TP * * * * LINE SPEED default for Fastnet Adapter is 100 * * /* not for Ethernet Adapter */ * * * * If you select AUTODETECT for Fastnet adapter, the driver will auto* * detect both media type and line speed. * ********************************************************************** 6. Bind IPX to the LAN driver. At the NetWare server prompt, type: :BIND IPX PCI40 <Enter> 7. After pressing <Enter> the computer prompts you for the Network Number. For details on how to assign this number, please consult your NetWare 386 Installation Manual. NetWare DOS ODI Workstation Driver Installation (NetWare v3.11) =============================================================== This section describes the procedure to install the NetWare v3.11 workstation driver for your adapter. Requirements: ------------- 32-Bit PCI (fast) Ethernet Adapter driver diskette (PCIMLID.COM) Installation Procedure: ----------------------- Before you start with the installation process, make sure that the adapter is properly installed and configured. Make sure the NetWare operating system is properly installed. 1. Run the following command in the order below and press <Enter>: lsl pcimlid ipxodi netx 2. You can now log into your network. NetWare DOS ODI Driver Installation (NetWare 3.12) ================================================== Requirements: ------------- 32-Bit PCI (fast) Ethernet Adapter Driver Diskette (PCI40.LAN) Installation Procedure: ----------------------- Before you start with the installation process, make sure that the Novell NetWare 386 v3.12 server is properly installed. Your adapter should also be installed in your workstation. 1. Insert the driver diskette into your floppy drive (A: or B:) and check the contents of subdirectory \NETWARE\ODI\3.1X It should contain the following file : PCI40.LAN <--- Novell NetWare V4.X, 3.1X Server Driver for 32-Bit PCI Fastnet/Ethernet Adapter ETHERTSM.NLM MSM31X.NLM 2. Copy the above LAN files from the Driver Diskette into the NetWare 386 subdirectory of your server. 3. Run SERVER.EXE from your server. You will see a series of NetWare messages onscreen. 4. You need to load all required NLM modules before you can load the server driver. You must load msm31x.nlm first. If you boot in MS-DOS 6.x environment, then it will show ".... is msm NOT msm31x..." warning message. You can ignore it. Then load ethertsm.nlm. 5. When the NetWare 386 prompt appears (preceded by a colon mark), load your server driver. Simply type: : LOAD [d:]PCI40 TP [AUI,BNC,AUTODETECT,TP_FULL_DUPLEX] LINE_SPEED=100 [10,100] /* for Fastnet only */ FRAME=ETHERNET_802.3 <Enter> (Command Syntax : LOAD [d:]<Driver Name> <MEDIUM TYPE> LINE_SPEED=<Line Speed> FRAME=<FRAME TYPE>) ********************************************************************** * IMPORTANT! * * * * MEDIUM TYPE default for Ethernet Adapter is AUTODETECT, * * for Fastnet Adapter is TP. * * * * LINE SPEED default for Fastnet Adapter is 100 * * /* not for Ethernet Adapter */ * * * * If you select AUTODETECT for Fastnet adapter, the driver will auto* * detect both media type and line speed. * ********************************************************************** 6. Bind IPX to the LAN driver. At the NetWare server prompt, type: :BIND IPX PCI40 <Enter> 7. After pressing <Enter> the computer prompts you for the Network Number. For details on how to assign this number, please consult your NetWare 386 Installation Manual. NetWare DOS ODI Driver Installation (NetWare 4.X) ================================================== Requirements: ------------- 32-Bit PCI (fast) Ethernet Adapter Driver Diskette (PCI40.LAN) Installation Procedure: ----------------------- 1. Insert the driver diskette into your floppy drive (A: or B:) and check the contents of subdirectory \NETWARE\ODI\4.X It should contain the following file : PCI40.LAN <--- Novell NetWare V4.X, 3.1X Server Driver for 32-Bit PCI Fastnet/Ethernet Adapter PCI40.LDI <--- Novell NetWare V4.0x Server Driver Installation Information File MSM.NLM ETHERTSM.NLM AUTOEXEC.NCF 2. At the NetWare prompt (indicated by the Server name), run the INSTALL.NLM program by typing: server name: LOAD INSTALL <Enter> 3. Select "Maintenance/Selective Install" and press <Enter>. 4. Select "LAN Driver Options (Configure/Load/...)" and press <Enter>. 5. Press the <Ins> key to specify other drivers to install. 6. Press <F3> and specify the driver path (A:\NETWARE\ODI\4.X) and press <Enter>. 7. The PCI40.LAN driver should be on your choice list for the "Select a LAN Driver' field. Choose this driver to start the driver loading and binding procedure. This will allow you to load and bind all 4 frame types supported by NetWare. 8. Next time you start up your system, simply follow the steps from 2 to 4 to complete the installation. Installation notes: ------------------- 1. When loading PCI40.LAN, it will check whether MSM and ETHERTSM have been loaded. If not, it will try to load these two modules automatically. So after PCI40.LAN is loaded, if you type "MODULES" command under the DOS prompt, you will see that two extra modules, namely, MSM.NLM and ETHERTSM.NLM are also loaded. 2. The default frame type for the PCI40.LAN binding is Ethernet_802.2 and not Ethernet_802.3. This is the significant difference between V3.11 and V4.X drivers. The PCI40.LAN also supports the NetWare V3.11 environment. However, it requires loading of some patch NLMs before loading it. 3. Remember to specify LASTDRIVE=Z in the CONFIG.SYS file. 4. Edit the NET.CFG if you want to change some parameters. For example, if you're using a NetWare 3.11 workstation and want to log into a NetWare v4.X server which uses Ethernet 802.3 frame type, while NetWare v4.X uses Ethernet 802.2. Before you can log into the NetWare v4.X, make sure there is a protocol binding for Ethernet 802.3 in the server's NET.CFG file. This is normally included in the [MLID] section. A sample NET.CFG file is given below: LINK DRIVER PCIMLID TP ;; Medium type in used : : --- All trademarks and brand names mentioned are trademarks or registered trademarks of their respective companies. -- THE END --