32-Bit PCI (fast) Ethernet Adapter
               NetWare DOS ODI Driver Installation
              ======================================


NetWare DOS ODI Driver Installation (NetWare 3.11)
==================================================

Requirements:
-------------
	32-Bit PCI (fast) Ethernet Adapter Driver Diskette  (PCI40.LAN)

Installation Procedure:
-----------------------
	Before you start with the installation process, make sure that
	the Novell NetWare 386 v3.11 server is properly installed.
	Your adapter should also be installed in your workstation.

	1. Insert the driver diskette into your floppy drive (A: or B:)
	   and check the contents of subdirectory  \NETWARE\ODI\3.1X
	   It should contain the following file :
 
	   PCI40.LAN  <--- Novell NetWare V4.X, 3.1X Server Driver for 
	                      32-Bit PCI Fastnet/Ethernet Adapter
	   AUTOEXEC.NCF
	   ETHERTSM.NLM
	   LSLENH.NLM
	   MONITOR.NLM
	   MSM31X.NLM
	   PATCHMAN.NLM

	2. Copy the above LAN files from the driver diskette into the 
	   NetWare 386 subdirectory of your server.

	3. Run SERVER.EXE from your server. You will see a series of NetWare 
	   messages onscreen.

	4. You need to load all required NLM modules before you can load 
           the server driver.  You can set up the AUTOEXEC.NCF file in the 
           \netware\odi\3.1X directory to run the loading.

        5. When the NetWare 386 prompt appears (preceded by a colon mark),
           load your server driver. Simply type:

	   : LOAD [d:]PCI40 TP[AUI,BNC,AUTODETECT,TP_FULL_DUPLEX]
	     LINE_SPEED=100 [10,100] /* for Fastnet only */
	     FRAME=ETHERNET_802.3  <Enter>

   	   (Command Syntax : LOAD [d:]<Driver Name> <MEDIUM TYPE> 
	    LINE_SPEED=<Line Speed> FRAME=<FRAME TYPE>)

   	**********************************************************************
   	*  IMPORTANT!                                                        *     
   	*                                                                    *     
  	*  MEDIUM TYPE default for Ethernet Adapter is AUTODETECT,           *     
  	*  for Fastnet Adapter is TP                                         *     
  	*                                                                    *     
  	*  LINE SPEED default for Fastnet Adapter is 100                     *     
  	*   /* not for Ethernet Adapter */                                   *     
   	*                                                                    *     
   	*  If you select AUTODETECT for Fastnet adapter, the driver will auto*     
   	*  detect both media type and line speed.                            *     
   	**********************************************************************

	6. Bind IPX to the LAN driver. At the NetWare server prompt, type:

   	   :BIND IPX PCI40 <Enter>

	7. After  pressing <Enter> the computer prompts you for the Network 
	   Number. For details on how to assign this number, please consult 
	   your NetWare 386 Installation Manual.



NetWare DOS ODI Workstation Driver Installation (NetWare v3.11)
===============================================================
	This section describes the procedure to install the NetWare v3.11 
	workstation driver for your adapter.

Requirements:
-------------                                       
	32-Bit PCI (fast) Ethernet Adapter driver diskette  (PCIMLID.COM)

Installation Procedure:
-----------------------
	Before you start with the installation process, make sure that
	the adapter is properly installed and configured. Make sure
	the NetWare operating system is properly installed.

	1. Run the following command in the order below and
   	   press <Enter>:

	   lsl
	   pcimlid
	   ipxodi
	   netx

	2. You can now log into your network.


NetWare DOS ODI Driver Installation (NetWare 3.12)
==================================================

Requirements:
-------------                                                     
	32-Bit PCI (fast) Ethernet Adapter Driver Diskette  (PCI40.LAN)

Installation Procedure:
-----------------------
	Before you start with the installation process, make sure that
	the Novell NetWare 386 v3.12 server is properly installed.
	Your adapter should also be installed in your workstation.

	1. Insert the driver diskette into your floppy drive (A: or B:)
   	   and check the contents of subdirectory  \NETWARE\ODI\3.1X
   	   It should contain the following file :

	   PCI40.LAN     <--- Novell NetWare V4.X, 3.1X Server Driver for 
	                      32-Bit PCI Fastnet/Ethernet Adapter
	   ETHERTSM.NLM
	   MSM31X.NLM

	2. Copy the above LAN files from the Driver Diskette into the 
	   NetWare 386 subdirectory of your server.

	3. Run SERVER.EXE from your server. You will see a series of NetWare 
	   messages onscreen.

	4. You need to load all required NLM modules before you can load 
           the server driver. You must load msm31x.nlm first. If you boot 
	   in MS-DOS 6.x environment, then it will show ".... is msm NOT 
	   msm31x..." warning message. You can ignore it. Then load 
	   ethertsm.nlm.

	5. When the NetWare 386 prompt appears (preceded by a colon mark),
	   load your server driver. Simply type:

	   : LOAD [d:]PCI40 
	     TP [AUI,BNC,AUTODETECT,TP_FULL_DUPLEX]
             LINE_SPEED=100 [10,100]               /* for Fastnet only */
             FRAME=ETHERNET_802.3  <Enter>

   	   (Command Syntax : LOAD [d:]<Driver Name> <MEDIUM TYPE> 
	    LINE_SPEED=<Line Speed> FRAME=<FRAME TYPE>)

	**********************************************************************
	*  IMPORTANT!                                                        *
	*                                                                    *
	*  MEDIUM TYPE default for Ethernet Adapter is AUTODETECT,           *
	*  for Fastnet Adapter is TP.                                        *
	*                                                                    *
	*  LINE SPEED default for Fastnet Adapter is 100                     *
	*   /* not for Ethernet Adapter */                                   *
	*                                                                    *
	*  If you select AUTODETECT for Fastnet adapter, the driver will auto*
	*  detect both media type and line speed.                            *
	**********************************************************************

	6. Bind IPX to the LAN driver. At the NetWare server
	   prompt, type:

	   :BIND IPX PCI40 <Enter>

	7. After pressing <Enter> the computer prompts  you  for
	   the Network Number. For details on how to assign this
	   number, please consult your NetWare 386 Installation Manual.




NetWare DOS ODI Driver Installation (NetWare 4.X)
==================================================

Requirements:
-------------
32-Bit PCI (fast) Ethernet Adapter Driver Diskette  (PCI40.LAN)

Installation Procedure:
-----------------------
	1. Insert the driver diskette into your floppy drive (A: or B:)
	   and check the contents of subdirectory  \NETWARE\ODI\4.X
	   It should contain the following file :

	   PCI40.LAN     <--- Novell NetWare V4.X, 3.1X Server Driver for 
                              32-Bit PCI Fastnet/Ethernet Adapter
   	   PCI40.LDI     <--- Novell NetWare V4.0x Server Driver 
	                      Installation Information File
	   MSM.NLM
	   ETHERTSM.NLM
	   AUTOEXEC.NCF

	2. At the NetWare prompt (indicated by the Server name),
   	   run the INSTALL.NLM program by typing:

   	   server name: LOAD INSTALL <Enter>

	3. Select "Maintenance/Selective Install" and press <Enter>.

	4. Select "LAN Driver Options (Configure/Load/...)"
	   and press <Enter>.

	5. Press the <Ins> key to specify other drivers to install.

	6. Press <F3> and specify the driver path (A:\NETWARE\ODI\4.X)
	   and press <Enter>.

	7. The PCI40.LAN driver should be on your choice list for the 
	   "Select a LAN Driver' field. Choose this driver to start the 
	   driver loading and binding procedure. This will allow you to 
	   load and bind all 4 frame types supported by NetWare.

	8. Next time you start up your system, simply follow the steps
   	   from 2 to 4 to complete the installation.


Installation notes:
-------------------

	1. When loading  PCI40.LAN, it will check whether MSM and ETHERTSM 
	   have been loaded.  If not, it will try to load these two modules 
	   automatically.  So after PCI40.LAN is loaded, if you type 
	   "MODULES" command under the DOS prompt, you will see that two 
	   extra modules, namely, MSM.NLM and ETHERTSM.NLM are also loaded.

	2. The default frame type for the PCI40.LAN binding is
	   Ethernet_802.2 and not  Ethernet_802.3.  
	   This is the significant difference between V3.11 and V4.X drivers.

	   The PCI40.LAN also supports the NetWare V3.11 environment.
	   However, it requires loading of some patch NLMs before loading 
	   it.

	3. Remember to specify LASTDRIVE=Z in the CONFIG.SYS file.

	4. Edit the NET.CFG if you want to change some parameters.

	   For example, if you're using a NetWare 3.11 workstation and
	   want to log into a NetWare v4.X  server which uses Ethernet 
	   802.3 frame type, while NetWare v4.X uses Ethernet 802.2. Before 
	   you can log into the NetWare v4.X, make sure there is a protocol 
	   binding for Ethernet 802.3 in the server's NET.CFG file.

	   This is normally included in the [MLID] section. A sample
	   NET.CFG file is given below:

	   LINK DRIVER PCIMLID
	      TP       ;; Medium type in used
              :
              :


---
All trademarks and brand names mentioned are trademarks or registered 
trademarks of their respective companies.


-- THE END --