TABLE OF CONTENTS The files on this diskette are use to generate Novell Netware v 2.1x workstation and server drivers for the Racal InterLan NI5210. The following files are included: FILE SIZE DATE TIME NAME IN BYTES STAMP STAMP ------------ ------- -------- ------ E5210SH LAN 882 11-30-89 4:08p E5210SH OBJ 10237 11-30-89 3:50p B5210DRV OBJ 8337 11-30-89 3:53p D5210DRV OBJ 8337 11-30-89 3:57p C5210DRV OBJ 8337 11-30-89 3:55p A5210DRV OBJ 8337 11-30-89 3:52p E5210OS LAN 835 11-30-89 4:09p ============================================== ============================ NETWARE SETUP STEPS FOR THE RACAL INTERLAN NI5210 STEP 1: CONFIGURING THE RACAL INTERLAN NI5210 Configure the NI5210 by setting the memory base address, IRQ, memory size, host type, and media type. The following information can be used: |---------------------------| =================================== | Memory Base Address | JUMPER POSITIONS | Jumper Settings | B A |------|------|------|------| ________ Jumper | 17 | 16 | 15 | 14 | | * * | * |------|------|------|------| |______| C0000 | A | A | A | A | Jumper in "B" Position |------|------|------|------| _______ C4000 | A | A | A | B | * |* *| |------|------|------|------| |_____| C8000 | A | A | B | A | Jumper in "A" Position |------|------|------|------| =================================== CC000 | A | A | B | B | |------|------|------|------| B A D0000 | A | B | A | A | * * * 8 ----------- |------|------|------|------| * * * 7 I D4000 | A | B | A | B | * * * 6 O |------|------|------|------| * * * 5 B D8000 | A | B | B | A | * * * 4 A |------|------|------|------| * * * 3 ----------- DC000 | A | B | B | B | ----- * * * 17 |------|------|------|------| M * * * 16 E0000 | B | A | A | A | B * * * 15 |------|------|------|------| A * * * 14 E4000 | B | A | A | B | ----- * * * <---XME |------|------|------|------| * * * <---XRE E8000 | B | A | B | A | |------|------|------|------| JUMPER BLOCK 1 EC000 | B | A | B | B | ================================== |------|------|------|------| ============================================== ========================= I/O base jumper settings in the range of 200 to 3C8 are supported. The following list can be used for settings of 300 to 340. A complete list of settings is contained in the NI5210 Installation Manual. |-----------------------------| | I/O Base Address Jumper | | Settings | |-----------------------------| Jumper | 8 7 6 5 4 3 | |----|----|----|----|----|----| 300 | B | A | A | A | A | A | |----|----|----|----|----|----| 308 | B | A | A | A | A | B | |----|----|----|----|----|----| 310 | B | A | A | A | B | A | |----|----|----|----|----|----| 318 | B | A | A | A | B | B | |----|----|----|----|----|----| 320 | B | A | A | B | A | A | |----|----|----|----|----|----| 328 | B | A | A | B | A | B | |----|----|----|----|----|----| 330 | B | A | A | B | B | A | |----|----|----|----|----|----| 338 | B | A | A | B | B | B | |----|----|----|----|----|----| 340 | B | A | B | A | A | A | |----|----|----|----|----|----| ============================================== ======================== EXTENDED MEMORY (XME) AND BOOT PROM (XRE) JUMPERS These jumpers (located near IOBA and MBA jumpers) indicate the amount of buffer memory installed and if the card is equipped with the optional boot PROM. All NI5210 products have at least 8K of memory and a socket that is used either for the boot PROM or the additional 8K of buffer memory. XME and XRE should be set as follows: XME XRE |-------|----------| 8K byte RAM installed: | B | not used | |-------|----------| 16K byte RAM installed: | A | A | |-------|----------| Boot PROM installed: | A | B | |-------|----------| ============================================== ======================== INTERRUPT REQUEST LEVEL JUMPER BLOCK IRQ selections 2 through 7 are selected via the jumper labeled "IRQ" 2 3 4 5 6 7 Select the IRQ setting * * * * * * by placing the jumper over the IRQ * * * * * * appropriate pair. ============================================== ========================= HOST TYPE HOST TYPE selections are made as follows: W27 |---------| For IBM PC/XT or equivalent, ENABLE jumper w27: | * * | |---------| W27 For all other systems, DISABLE jumper w27: * * ============================================== ============================ STEP 2: INSTALLING THE DRIVER FILES FOR THE RACAL INTERLAN NI5210 1. Copy the E5210SH.LAN file to the SHGEN-1 diskette for "floppy disk" method or to the SHGEN-1 sub-directory if you are using "harddisk" or "network" method. It is a Shell driver description file. 2. Copy the Operating System driver description file E5210OS.LAN to the AUXGEN diskette for "floppy disk" method or to the AUXGEN sub-directory if you are using "harddisk" or "network" method. But if you are generating an External Bridge, the E5210OS.LAN file should be copied to the BRGEN-1 diskette or the BRGEN-1 sub-directory. 3. For the "floppy disk" method a blank disk needs to be formated and labeled. Use the DOS LABEL command to label the diskette as LAN_DRV_003. If the "harddisk" or "network" method is being used the a subdirectory under the NETWARE directory must be created. Use the DOS MKDIR command to create the LAN_DRV_.003 subdirectory. Copy the *.OBJ files to either the labeled diskette or subdirectory depending on which method is being used. 4. Run NETGEN and select the correct driver from the list of LAN adapter options to generate the file server operating system. 5. Run SHGEN and select the correct driver from the list of LAN adapter options to generate the workstation shell. 6. Run BRGEN and select the correct driver from the list of LAN adapter options to generate the external bridge software. ============================================== ============================ RACAL INTERLAN CUSTOMER SUPPORT AND ORDERS FOR MANUALS, DRIVERS OR ADDITIONAL PRODUCTS. First line support for your Racal InterLan products should be obtained from your VAR or distributor who sold you the product. If additional assistance is needed ... - for technical or installation assistance - for additional manuals or Racal InterLan products - for general product information ... please call Racal InterLan in Massachussetts (U.S.A) at: 1-800-LAN TALK or 1-508-263-9929 FAX services are available at: 1-508-263-8655 TELEX services are available at: 6200 4561 ============================================== ========================== DRIVER UPDATES THROUGH THE RACAL INTERLAN ON-LINE BULLETIN BOARD SERVICE Racal InterLan maintains a bulletin board service for our customers that allows the electronic downloading of drivers, product information revisions and updates for all of our products. This bulletin board can be accessed as follows Phone: 1-508-264-4345 Modem Settings: 8/N/1 300, 1200 or 2400 baud. XMODEM protocol There is an index of all the files contained on the board. To access this index, use choice 1 then choice 6 from the main menu. ============================================== ============================