NOVELL TECHNICAL INFORMATION DOCUMENT TITLE: Large Drive Remirroring Patch DOCUMENT ID: TID000011 DOCUMENT REVISION: A DATE: 01JUL93 ALERT STATUS: Yellow INFORMATION TYPE: Symptom Solution README FOR: 215MIR.EXE NOVELL PRODUCT and VERSION: NetWare Pre 3.11 and 2.2 ABSTRACT: This patch repairs a mirroring problem with SFT NetWare v2.15c. The patch allows remirroring of large drives (600MB). _________________________________________________________________ DISCLAIMER THE ORIGIN OF THIS INFORMATION MAY BE INTERNAL OR EXTERNAL TO NOVELL. NOVELL MAKES EVERY EFFORT WITHIN ITS MEANS TO VERIFY THIS INFORMATION. HOWEVER, THE INFORMATION PROVIDED IN THIS DOCUMENT IS FOR YOUR INFORMATION ONLY. NOVELL MAKES NO EXPLICIT OR IMPLIED CLAIMS TO THE VALIDITY OF THIS INFORMATION. _________________________________________________________________ Self-Extracting File Name: 215MIR.EXE Files Included Size Date Time 215MIR.TXT (This File) FLAG.EXE 28655 3-02-90 11:12a PEXE.BAT 63 3-02-90 11:12a PATCH.MSG 312 3-02-90 11:12a PATCH.TOP 86 3-02-90 11:12a PATCH.018 140 3-02-90 11:12a PATEXE.EXE 23752 3-01-90 10:21p This patch repairs a mirroring bug in the sft code of NETWARE 2.15X. The patch allows the remirror command to copy VIT sectors 22-25 in addition to the usuall sectors 16 and 17. The problem is only present on large drives (600 Meg). The programs and data in this subdirectory are for patching the net$os.exe or the net$os.ex1 file. Use the following procedure: Before you do anything, be sure all data on the server is backed up. 1) Login as supervisor to the server to be patched and change to the subdirectory sys:system. 2) Use the FLAG program to set the attributes on net$os.exe to read/write: flag net$os.exe rw 4) Copy the files on this floppy to sys:system. 5) Type the following: pexe net$os.exe 4) It will take about 10 seconds for the patches to finish and a message will come up indicating if the patches were successful or not. 5) An alternative method, is to leave the patch programs in one area and put a path on the filenames to be patched above. note: Note the net$os.ex1 file in the netgen area can also be patched before it is installed by netgen. If you do this type the following. pexe net$os.ex1 6) When finished, verify that the modify date has been changed and copy the newly modified net$os.ex1 back to its area in the netgen subdirectory. Or if you modified net$os.exe in sys:system, change the file attributes back to read only by typing "FLAG NET$OS.EXE RO". WARNING: THIS PATCH WILL NOT WORK ON OBJ FILES. ÿ