This file provides basic configuration information for the ULTRA 34F VL-BUS SCSI controller. For a more detailed instructions, please refer to the ULTRA 34F User Manual. 1. Jumper Settings (note : * denotes default settings) JP2 : Factory Use JP3 : Jumper Block 1 1-2 : Motor Spin Up Sequencing *OUT Automatically drive spin up IN Motor spin up from SCSI ID 0 to ID 7 3-4 : Synchronous Negotiation *OUT ULTRA 34F initiated negotiation IN Target initiated negotiation 5-6 7-8 : Interrupt Channel OUT OUT IRQ 15 *OUT IN IRQ 14 IN OUT IRQ 11 IN IN IRQ 10 9-10 : SCSI Parity Control *OUT Parity enabled IN Parity disabled 11-12 13-14 15-16 : BIOS Address OUT OUT OUT Disable OUT OUT IN C4000 - C7FFF *OUT IN OUT C8000 - CBFFF OUT IN IN CC000 - CFFFF IN OUT OUT D0000 - D3FFF IN OUT IN D4000 - D7FFF IN IN OUT D8000 - DBFFF IN IN IN DC000 - DFFFF JP4 : Jumper Block 2 1-2 3-4 : I/O Address *OUT OUT 330H OUT IN 340H IN OUT 230H IN IN 130H 5-6 : BIOS Support for More Than 2 Hard Disk Drives *OUT Maximum 2 hard disk drives per system IN Maximum 7 hard disk drives per controller 7-8 9-10 : Head Mapping Mode OUT OUT 16 head 63 sector mapping *OUT IN 64 head 32 sector mapping IN OUT 64 head 63 sector mapping IN IN 64 head 32 sector mapping 11-12 13-14 15-16 : Controller SCSI ID OUT OUT OUT Reserved OUT OUT IN 1 OUT IN OUT 2 OUT IN IN 3 IN OUT OUT 4 IN OUT IN 5 IN IN OUT 6 *IN IN IN 7 JP10 : Factory Use 2. Connectors J1 : 50 pin internal SCSI connector J2 : 50 pin high density external SCSI connector JP5 : 4 pin controller activity LED connector 3. ULTRA BIOS Utility To invoke the on-board BIOS utility, after a full system bootup to DOS operating system, use the DOS "DEBUG" program to access the BIOS utility: a. Load the DEBUG program by typing DEBUG after the DOS prompt ( ">" sign ) b. Once in the DEBUG program, following the prompt ( "-" sign ), type g=c800:5 or whatever BIOS address the board is jumpered to. The ULTRA BIOS utility displays SCSI ID, type, manufacturer, model number, and mapping mode for each SCSI device attached to the ULTRA 34F; it also provides functions for exercising SCSI devices. Verify : Non-destructive media verfication for hard disks, removable hard disks and magneto optical devices. Scan : Same function as verify except it will issue "reassign bad block" to the drive when defective sectors are found. Format : Low level format of the SCSI device. CFormat: Low level format of the SCSI device with the certification option (CLIST) which re-sequences the good blocks.