The graphics accelerator board comes with four driver diskettes. These are the: Trio32/64 Utilities, DOS and Windows 3.1 Drivers Trio32/64 Drivers for Windows NT 3.5 Trio32/64 Drivers for OS/2 2.0/2.1 Disk 1 of 2 Trio32/64 Drivers for OS/2 2.0/2.1 Disk 2 of 2 Trio32/64 Utilities, DOS and Windows 3.1 Drivers ================================================ This diskette, Trio32/64 Utilities, DOS and Windows 3.1 Drivers, contains the following drivers and utilities: Windows 3.1 driver and Galileo utility Windows DPMS Program AutoCAD Release 11 driver AutoCAD Release 12 driver MicroStation 4.0 driver MicroStation 5.0 driver Refresh rate and FCON utility Installation Procedure 1. Insert the Trio32/64 Utilities, DOS and Windows 3.1 Drivers diskette into a floppy drive. 2. At the DOS prompt, type: INSTALL A: C: 3. INSTALL will create a S3INSTLL directory under drive C and copy all the files contained in the diskette into the S3INSTLL directory. 4. The Drivers Installation Screen will now appear on the screen. 5. Select the driver you wish to install and press . Refresh Rate and FCON Utilities ------------------------------- Installation 1. Change the current directory to the S3INSTLL directory. 2. Type INSTALL. The Driver Installation screen will appear. Highlight the Refresh Rate and FCON Utility option and press . 3. You will be prompted to enter the drive and directory where you would like the refresh rate and FCON utilities installed. Enter the drive/directory and press . All the files will be copied into the directory. FCON Utility FCON.EXE is a utility that allows the user to easily enable the feature connector's function for test purposes. This utility is only required for 2MB and 4MB configurations as the BIOS automatically enables the feature connector's function for 1MB configurations. Usage: FCON [e|d] [p|v] where: e = enable; d = disable p = pass-through; v = VAFC Refresh Rate The S3REFRSH utility requires that a mouse driver be installed. Without a mouse driver, command line parameters will be required using the following options: Usage (without mouse): S3REFRSH X Y where: X = 640, 800, 1024, 1280 Y = 0 (56Hz), 1 (60Hz), 2 (70Hz), 3 (72Hz), 4 (75Hz), 5 (interlaced) Note: The 1600x1200 and 1152x864 resolutions each have single refresh rate, therefore, these resolutions does not require the S3REFRSH utility. If a mouse driver was installed, a menu will appear on the screen upon running S3REFRSH. The left side of the screen shows the available refresh rates. On top of the table are the corresponding resolutions. Select the desired resolution by clicking on the boxes. "X" marks mean the selections are not valid; selected refresh rates are defined by check marks. Click on the Exit button to set the new refresh rate. You will be asked if you would like to save the changes in the AUTOEXEC.BAT. Choose Yes if you wish to use the new refresh rate values everytime the system boots. Windows 3.1 Driver ------------------ 1. Change the current directory to the S3INSTLL directory. 2. Type INSTALL. The Driver Installation screen will appear. Highlight the Windows 3.1 Driver and Galileo Utility option and press . 3. You will be prompted to enter the drive and directory where Windows was installed. Enter the drive/directory and press . All the files will be copied into the Windows directory. 4. Run Windows. 5. Open the Control Panel under the Main Group of the Program Manager. 6. Double-click the Galileo icon. The Galileo screen will appear. Select the appropriate resolution, refresh rate and color. 7. Restart Windows. Windows DPMS Program -------------------- The driver for the Windows DPMS program is included in the Windows 3.1 drivers. Installing the Windows 3.1 drivers automatically installs the Windows DPMS program. To use the Windows DPMS program: 1. Double-click the Control Panel under the Main group of the Program Manager. 2. The Control Panel screen will appear. Double-click the Desktop icon. 3. The Desktop screen will appear. From the Screen Saver Name option, select S3 Green PC. 4. Click the Setup option. 5. The S3 DPMS 1.0 screen will appear allowing you to set the password. If you enabled the Password Protected option, you will be prompted for the password everytime you wake up the system to return to normal mode. 6. Select S3 Green PC Options to set the time before your system enters the Standby, Suspend and Monitor Off modes. Note: The Enable Green PC Monitor Feature option must be enabled to allow your system to enter the Standby, Suspend or Monitor Off mode. AutoCAD Release 11/12 Driver ---------------------------- The Aquila driver is a professional quality PADI (Protected mode Autodesk Driver Interface) combined display and rendering device driver to be used with AutoCAD Release 11/12, 3D Studio 1.0/2.0, and AutoShade 2.1. The table below shows the supported display and/or rendering resolutions. ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ ³ Resolution ³ Colors ³ Minimum Video Memory (MB) ³ Display = D ³ ³ ³ ³ ³ Rendering = R ³ ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´ ³ 640x480 ³ 256 ³ 1 ³ D, R ³ ³ 640x480 ³ 64K ³ 1 ³ R ³ ³ 640x480 ³ 16.7M ³ 1 ³ R ³ ³ ³ ³ ³ ³ ³ 800x600 ³ 16 ³ 1 ³ D ³ ³ 800x600 ³ 64K ³ 1 ³ R ³ ³ 800x600 ³ 16.7M ³ 2 ³ R ³ ³ ³ ³ ³ ³ ³ 1024x768 ³ 256 ³ 1 ³ D, R ³ ³ 1024x768 ³ 64K ³ 2 ³ R ³ ³ ³ ³ ³ ³ ³ 1152x864 ³ 256 ³ 1 ³ D, R ³ ³ ³ ³ ³ ³ ³ 1280x1024 ³ 256 ³ 2 ³ D, R ³ ³ 1280x1024 ³ 64K ³ 4 ³ R ³ ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ Installation 1. Change the current directory to the S3INSTLL directory. 2. Type INSTALL. The Driver Installation screen will appear. Highlight the AutoCAD Release 11 Driver or AutoCAD Release 12 Driver option and press . 3. You will be prompted to enter the drive and directory where AutoCAD Release 11 or AutoCAD Release 12 was installed. Enter the drive/directory and press . All the files will be copied into the AutoCAD Release 11 or AutoCAD Release 12 directory. MicroStation 4.0 Driver ----------------------- The MicroStation 4.0 driver supports MicroStation PC 4.0 for the DOS 386 protected mode environment. If you are using this driver for the first time, it will show you a menu of all the available resolution modes. Select a resolution. A configuration file will be created that the driver will use for subsequent MicroStation sessions. To reconfigure the driver, erase the files \USTAT40\DRIVERS\*.CFG and run the USTATION.BAT file again. Installation 1. Change the current directory to the S3INSTLL directory. 2. Type INSTALL. The Driver Installation screen will appear. Highlight the MicroStation 4.0 Driver option and press . 3. You will be prompted to enter the drive and directory where MicroStation 4.0 was installed. Enter the drive/directory and press . All the files will be copied into the Microstation 4.0 directory. 4. Change the current directory to the \USTAT40 subdirectory or the directory which contains the MicroStation application. 5. Run the USCONFIG program to select the new device driver. a. Select "Display Adapters" entry. b. Select "VENDOR SUPPLIED DRIVER" option. c. Select "PMGL4S3 v1.XX for S3 Accelerators" option. d. Select second adapter options as needed. e. Select Swap Screen Status "Y" or "N". f. Select "Exit and Save". g. Run USTATION.BAT from the \USTAT40 subdirectory. h. Select the desired mode from the list of supported resolutions. i. MicroStation PC 4.0 will now be launched. SWAP screen capabilities are supported if a 256 color mode is configured. If the initialization code is unable to determine which mode to use, it will always default to the 640x480, 256 color mode. The driver will exit if it is not able to find an S3-based graphics card. MicroStation 5.0 Driver ----------------------- The MicroStation 5.0 driver supports MicroStation PC 5.0 for the DOS 386 protected mode environment. If you are using this driver for the first time, it will show you a menu of all the available resolution modes. Select a resolution. A configuration file will be created that the driver will use for subsequent MicroStation sessions. To reconfigure the driver, erase the files \USTAT50\DRIVERS\*.CFG and run the MicroStation 5.0 USTATION.BAT file again. The supported modes are as follows: ÚÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄ¿ ³ Mode ³ Resolution ³ Colors ³ ³ÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄ´ ³ 0 ³ 640x480 ³ 256 ³ ³ 1 ³ 800x600 ³ 16 ³ ³ 2 ³ 800x600 ³ 256 ³ ³ 3 ³ 1024x768 ³ 16 ³ ³ 4 ³ 1024x768 ³ 256 ³ ³ 5 ³ 1152x864 ³ 256 ³ ³ 6 ³ 1280x1024 ³ 16 ³ ³ 7 ³ 1280x1024 ³ 256 ³ ³ 8 ³ 1600x1200 ³ 256 ³ ÀÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÙ Installation 1. Change the current directory to the S3INSTLL directory. 2. Type INSTALL. The Driver Installation screen will appear. Highlight the MicroStation 5.0 Driver option and press . 3. You will be prompted to enter the drive and directory where MicroStation 5.0 was installed. Enter the drive/directory and press . All the files will be copied into the Microstation 5.0 directory. 4. Change the current directory to the \USTAT50 subdirectory or the directory which contains the MicroStation application. 5. Run the USCONFIG program to select the new device driver. a. Select Generate for: "DOS" b. Select "Display Adapters" entry. c. Select Right Screen Graphics Adapter "MGL5S3 v1.XX for S3 Accelerators" option. d. Select Left Screen Graphics Adapter "as needed" e. Select Swap Screen Status "Y" or "N". f. Select "Exit and Save". g. Run the USTATION.BAT from the \USTAT50 subdirectory. h. Select the desired mode from the list of supported resolutions. i. Respond "Y" or "N" to use hardware scrolling. By accepting the default "Yes", scrolling will be faster but thick diagonal lines will display notches after the scroll. (Selecting the UPDATE icon from the Main Palette will refresh the display.) j. MicroStation 5.0 will now be launched. SWAP screen capabilities are supported if a 256 color mode is configured. If the initialization code is unable to determine which mode to use, it will always default to the 640x480, 256 color mode. The driver will exit if it is not able to find an S3-based graphics card.